DTC B2343 Position Initialization Incomplete |
| DTC Code | DTC Detection Condition | Trouble Area |
| B2343 | The sliding roof drive gear sub-assembly has not been initialized. |
|

| 1.INITIALIZE SLIDING ROOF DRIVE GEAR SUB-ASSEMBLY |
Check that the sliding roof drive gear sub-assembly can be initialized (Click here).
|
| ||||
| OK | |
| 2.CHECK FOR DTC |
Clear the DTCs (Click here).
Check for DTCs (Click here).
| Result | Proceed to |
| DTC is not output | A |
| DTC B2343 is output | B |
|
| ||||
| A | ||
| ||
| 3.INSPECT MAP LIGHT ASSEMBLY |
![]() |
Remove the map light assembly (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 5 (UP) - 1 (GND) | Tilt up switch pressed | Below 1 Ω |
| 5 (UP) - 1 (GND) | Tilt up switch not pressed | 10 kΩ or higher |
| 4 (DOWN) - 1 (GND) | Tilt down switch pressed | Below 1 Ω |
| 4 (DOWN) - 1 (GND) | Tilt down switch not pressed | 10 kΩ or higher |
| 3 (OPN) - 1 (GND) | Slide open switch pressed | Below 1 Ω |
| 3 (OPN) - 1 (GND) | Slide open switch not pressed | 10 kΩ or higher |
| 2 (CLS) - 1 (GND) | Slide close switch pressed | Below 1 Ω |
| 2 (CLS) - 1 (GND) | Slide close switch not pressed | 10 kΩ or higher |
| *a | Component without harness connected (Map Light Assembly) |
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (SLIDING ROOF ECU - SLIDING ROOF SWITCH AND BODY GROUND) |
Disconnect the S8 ECU connector.
Disconnect the U2 map light connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| S8-10 (UP) - U2-5 (UP) | Always | Below 1 Ω |
| S8-8 (DWN) - U2-4 (DOWN) | Always | Below 1 Ω |
| S8-7 (OPN) - U2-3 (OPN) | Always | Below 1 Ω |
| S8-9 (CLS) - U2-2 (CLS) | Always | Below 1 Ω |
| U2-1 (GND) - Body ground | Always | Below 1 Ω |
| S8-2 (E) - Body ground | Always | Below 1 Ω |
| S8-10 (UP) or U2-5 (UP) - Body ground | Always | 10 kΩ or higher |
| S8-8 (DWN) or U2-4 (DOWN) - Body ground | Always | 10 kΩ or higher |
| S8-7 (OPN) or U2-3 (OPN) - Body ground | Always | 10 kΩ or higher |
| S8-9 (CLS) or U2-2 (CLS) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||