Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)

DTC    B1411/11    Room Temperature Sensor Circuit

for Preparation Click here


DESCRIPTION

The cooler thermistor (room temperature sensor) for the front seat is installed in the instrument panel to detect the room temperature and control the heater and air conditioner auto mode. The resistance of the room temperature sensor changes in accordance with the front room temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the room temperature sensor and reads voltage changes as the resistance of the room temperature sensor changes. This sensor also sends the appropriate signals to the air conditioning amplifier assembly.

DTC Code
DTC Detection Condition
Trouble Area
B1411/11
An open or short in the cooler thermistor (room temperature sensor) circuit.
  1. Cooler thermistor (room temperature sensor)
  2. Harness or connector
  3. Air conditioning amplifier assembly

WIRING DIAGRAM


E156584E67


INSPECTION PROCEDURE

1.READ VALUE USING TECHSTREAM (ROOM TEMPERATURE SENSOR)
  1. Use the Data List to check if the cooler thermistor (room temperature sensor) is functioning properly (Click here).

    Air Conditioner 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Room Temperature Sensor
    Cooler thermistor (room temperature sensor) /
    Min.: -6.5°C (20.3°F)
    Max.: 57.25°C (135.05°F)
    Actual room temperature for front seat displayed
    Open in the circuit: -6.5°C (20.3°F).
    Short in the circuit: 57.25°C (135.05°F).

    OK:
    The display is as specified in the normal condition column.

    Result 
    Result
    Proceed to
    OK (When troubleshooting according to problem symptoms table)
    A
    OK (When troubleshooting according to the DTC)
    B
    NG
    C



B
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)

C
Go to step 2
A

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)  

2.INSPECT COOLER THERMISTOR (ROOM TEMPERATURE SENSOR)


    E184842E02
  1. Remove the cooler thermistor (room temperature sensor) (Click here).

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    10°C (50°F)
    3.00 to 3.73 kΩ
    15°C (59°F)
    2.45 to 2.88 kΩ
    20°C (68°F)
    1.95 to 2.30 kΩ
    25°C (77°F)
    1.60 to 1.80 kΩ
    30°C (86°F)
    1.28 to 1.47 kΩ
    35°C (95°F)
    1.00 to 1.22 kΩ
    40°C (104°F)
    0.80 to 1.00 kΩ
    45°C (113°F)
    0.65 to 0.85 kΩ
    50°C (122°F)
    0.50 to 0.70 kΩ
    55°C (131°F)
    0.44 to 0.60 kΩ
    60°C (140°F)
    0.36 to 0.50 kΩ

    Text in Illustration 
    *a
    Sensing Portion
    *b
    Resistance
    *c
    Allowable Range
    *d
    Temperature

    NOTICE:
    1. Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (refer to the graph).



NG
REPLACE COOLER THERMISTOR (ROOM TEMPERATURE SENSOR) (Click here)
OK


3.CHECK HARNESS AND CONNECTOR (ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)
  1. Disconnect the F26 sensor connector.

  1. Disconnect the F42 amplifier connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    F26-1 - F42-29 (TR)
    Always
    Below 1 Ω
    F26-2 - F42-34 (SG-1)
    F42-29 (TR) - Body ground
    Always
    10 kΩ or higher
    F42-34 (SG-1) - Body ground



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)