Home › Vehicle Interior › THEFT DETERRENT / KEYLESS ENTRY › THEFT DETERRENT SYSTEM

THEFT DETERRENT SYSTEM > Security Horn Circuit

for Preparation Click here


DESCRIPTION

When the theft deterrent system is in the alarm sounding state, the main body ECU outputs a signal repeatedly at 0.4 second intervals, causing the security horn assembly to sound

WIRING DIAGRAM


B184350E04


INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

1.PERFORM ACTIVE TEST USING TECHSTREAM (SECURITY HORN)
  1. Operate the Techstream according to the steps on the display and select Active Test (Click here).

    Main Body 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Security Horn
    Security horn
    ON/OFF
    -

    OK:
    Security horn operates normally.



NG
Go to step 2
OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)  

2.INSPECT S-HORN RELAY


    E145692E01
  1. Remove the S-HORN relay from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    Battery voltage is not applied to terminals 1 and 2
    10 kΩ or higher
    3 - 5
    Battery voltage is applied to terminals 1 and 2
    Below 1 Ω



NG
REPLACE S-HORN RELAY
OK


3.INSPECT SECURITY HORN ASSEMBLY
  1. Remove the security horn (Click here).

  1. Apply battery voltage to the horn connector and check the operation of the horn.

    OK:
    Measurement Condition
    Specified Condition
    Battery positive (+) → Terminal 1
    Battery negative (-) → Horn bracket
    Horn sounds



NG
REPLACE SECURITY HORN ASSEMBLY (Click here)
OK


4.CHECK HARNESS AND CONNECTOR (ENGINE ROOM RELAY BLOCK - MAIN BODY ECU, SECURITY HORN AND BATTERY)
  1. Remove the S-HORN relay from the engine room relay block.

  1. Remove the main body ECU (Click here).

  1. Disconnect the A32 horn connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Relay block S-HORN relay terminal 1 - A-17 (SH)
    Always
    Below 1 Ω
    Relay block S-HORN relay terminal 3 - A32-1
    Always
    Below 1 Ω
    A-17 (SH) - Body ground
    Always
    10 kΩ or higher
    A32-1 - Body ground
    Always
    10 kΩ or higher

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    Relay block S-HORN relay terminal 2 - Body ground
    Always
    11 to 14 V
    Relay block S-HORN relay terminal 5 - Body ground
    Always
    11 to 14 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) (Click here)