ENGINE IMMOBILISER SYSTEM (w/ Entry and Start System) > Security Indicator Light Does not Blink |

| 1.CHECK FOR DTC |
Check for DTCs (Click here).
|
| ||||
| OK | |
| 2.READ VALUE USING GTS (IMMOBILISER) |
Using the GTS, read the Data List (Click here).
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Immobiliser | Engine immobiliser system status determined by certification ECU (smart key ECU assembly) / Set or Unset | Set: Engine immobiliser set (engine start prohibited) (engine switch off) Unset: Engine immobiliser unset (engine start permitted) [engine switch on (ACC) or on (IG)] | When the engine immobiliser system does not change to the unset state, this item can be used to determine if the cause is the certification ECU (smart key ECU assembly). |
|
| ||||
| OK | |
| 3.PERFORM ACTIVE TEST USING GTS (SECURITY INDICATOR) |
Check that the security indicator light illuminates when operating it with the Active Test (Click here).
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Security Indicator | Security indicator light | ON/OFF | - |
|
| ||||
| OK | ||
| ||
| 4.CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK - COMBINATION METER ASSEMBLY) |
Disconnect the 3B instrument panel junction block assembly connector.
Disconnect the D7 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3B-22 - D7-18 | Always | Below 1 Ω |
| D7-40 - Body ground | Always | Below 1 Ω |
| 3B-22 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 5.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY |
Remove the instrument panel junction block assembly (Click here).
Remove the main body ECU (network gateway ECU) from the instrument panel junction block assembly.
Measure the resistance according to the value(s) in the table below.

| *a | Component without harness connected (Instrument Panel Junction Block Assembly) | - | - |
| Tester Connection | Condition | Specified Condition |
| MB-27 (ILL) - 3B-22 | Always | Below 1 Ω |
|
| ||||
| OK | |
| 6.REPLACE COMBINATION METER ASSEMBLY |
Replace the combination meter assembly with a new one (Click here).
When the immobiliser is set, check that the security indicator light blinks.
|
| ||||
| OK | ||
| ||