POWER DOOR LOCK CONTROL SYSTEM > All Doors LOCK/UNLOCK Functions do not Operate Via Door Control Switch or Door Key Cylinder |


| 1.CHECK DOOR LOCK OPERATION |
Proceed to the next step according to the symptom listed in the table below.
| Result | Proceed to |
| Doors cannot be locked through power window regulator master switch assembly | A |
| Doors cannot be locked through power window regulator switch assembly*1 | B |
| Doors cannot be locked through driver side door key cylinder*2 | C |
|
| ||||
|
| ||||
| A | |
| 2.READ VALUE USING GTS (DOOR LOCK SW-LOCK AND DOOR LOCK SW-UNLOCK) |
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Main Body / Data List.
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Door Lock SW-Lock | Door control switch (power window regulator master switch assembly) lock signal / OFF or ON | OFF: Lock side of door control switch (power window regulator master switch assembly) not pushed ON: Lock side of door control switch (power window regulator master switch assembly) pushed | - |
| Door Lock SW-Unlock | Door control switch (power window regulator master switch assembly) unlock signal / OFF or ON | OFF: Unlock side of door control switch (power window regulator master switch assembly) not pushed ON: Unlock side of door control switch (power window regulator master switch assembly) pushed | - |
|
| ||||
| OK | ||
| ||
| 3.INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY |
![]() |
Remove the power window regulator master switch assembly (Click here).
Connect the E8*1 or F6*2 power window regulator master switch assembly connector.
Connect the cable to the negative(-) battery terminal.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E8-16 - E8-5 (GND) | Lock switch pushed | 9.15 V or higher |
| off | Below 1 V | |
| E8-15 - E8-5 (GND) | Unlock switch pushed | 9.15 V or higher |
| off | Below 1 V |
| Tester Connection | Switch Condition | Specified Condition |
| F6-16 - E8-5 (GND) | Lock switch pushed | 9.15 V or higher |
| off | Below 1 V | |
| F6-15 - E8-5 (GND) | Unlock switch pushed | 9.15 V or higher |
| off | Below 1 V |
| *A | for LHD |
| *B | for RHD |
| *a | Component with harness connected (Power Window Regulator Master Switch Assembly (Door Control Switch)) |
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (POWER WINDOW MASTER SWITCH - JUNCTION BLOCK AND BODY GROUND) |
for LHD:
Disconnect the 3A instrument panel junction block assembly connector.
Disconnect the E8 power window regulator master switch assembly (door control switch) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3A-51 - E8-16 | Always | Below 1 Ω |
| 3A-30 - E8-15 | Always | Below 1 Ω |
| E8-5 (GND) - Body ground | Always | Below 1 Ω |
| 3A-51 or E8-16 - Body ground | Always | 10 kΩ or higher |
| 3A-30 or E8-15 - Body ground | Always | 10 kΩ or higher |
for RHD:
Disconnect the 3A instrument panel junction block assembly connector.
Disconnect the F6 power window regulator master switch assembly (door control switch) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3A-51 - F6-16 | Always | Below 1 Ω |
| 3A-30 - F6-15 | Always | Below 1 Ω |
| F6-5 (GND) - Body ground | Always | Below 1 Ω |
| 3A-51 or F6-16 - Body ground | Always | 10 kΩ or higher |
| 3A-30 or F6-15 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 5.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY |
Remove the instrument panel junction block assembly (Click here).
Remove the main body ECU (network gateway ECU) from the instrument panel junction block assembly.

| *a | Component without harness connected (Instrument Panel Junction Block Assembly) | - | - |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| MB-17 (L) - 3A-51 | Always | Below 1 Ω |
| MB-19 (UL) - 3A-30 | Always | Below 1 Ω |
|
| ||||
| OK | ||
| ||
| 6.READ VALUE USING GTS (DOOR LOCK SW-LOCK AND DOOR LOCK SW-UNLOCK) |
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Main Body / Data List.
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Door Lock SW-Lock | Door control switch (power window regulator switch assembly) lock signal / OFF or ON | OFF: Lock side of door control switch (power window regulator switch assembly) not pushed ON: Lock side of door control switch (power window regulator switch assembly) pushed | - |
| Door Lock SW-Unlock | Door control switch (power window regulator switch assembly) unlock signal / OFF or ON | OFF: Unlock side of door control switch (power window regulator switch assembly) not pushed ON: Unlock side of door control switch (power window regulator switch assembly) pushed | - |
|
| ||||
| OK | ||
| ||
| 7.INSPECT POWER WINDOW REGULATOR SWITCH ASSEMBLY |
![]() |
Remove the power window regulator switch assembly (Click here).
Connect the F6 power window regulator switch assembly connector.
Connect the cable to the negative(-) battery terminal.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| F6-16 - F6-5 (GND) | Lock switch pushed | 9.15 V or higher |
| off | Below 1 V | |
| F6-15 - F6-5 (GND) | Unlock switch pushed | 9.15 V or higher |
| off | Below 1 V |
| *a | Component with harness connected (Power Window Regulator Switch Assembly (Door Control Switch)) |
|
| ||||
| OK | |
| 8.CHECK HARNESS AND CONNECTOR (POWER WINDOW SWITCH - JUNCTION BLOCK AND BODY GROUND) |
Disconnect the 3A and 3B instrument panel junction block assembly connectors.
Disconnect the F6 power window regulator switch assembly (door control switch) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3A-41 - F6-16 | Always | Below 1 Ω |
| 3B-20 - F6-15 | Always | Below 1 Ω |
| F6-5 (GND) - Body ground | Always | Below 1 Ω |
| 3A-41 or F6-16 - Body ground | Always | 10 kΩ or higher |
| 3B-20 or F6-15 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 9.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY |
Remove the instrument panel junction block assembly (Click here).
Remove the main body ECU (network gateway ECU) from the instrument panel junction block assembly.

| *a | Component without harness connected (Instrument Panel Junction Block Assembly) | - | - |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| MB-17 (L) - 3A-41 | Always | Below 1 Ω |
| MB-19 (UL) - 3B-20 | Always | Below 1 Ω |
|
| ||||
| OK | ||
| ||
| 10.READ VALUE USING GTS (DOOR KEY SW-LOCK AND DOOR KEY SW-UNLOCK) |
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Main Body / Data List.
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Door Key SW-Lock | Door key-linked lock switch signal/ ON or OFF | ON: Driver side door side key cylinder is turned to lock position OFF: Driver side door key cylinder is turned to unlock position | - |
| Door Key SW-ULock | Door key-linked unlock switch signal/ ON or OFF | ON: Driver side door key cylinder is turned to unlock position OFF: Driver side door key cylinder is turned to lock position | - |
|
| ||||
| OK | ||
| ||
| 11.INSPECT FRONT DOOR LOCK ASSEMBLY RH |
Remove the front door lock assembly RH (Click here).
Inspect the front door lock assembly RH (Click here).
|
| ||||
| OK | |
| 12.CHECK HARNESS AND CONNECTOR (MAIN BODY ECU - FRONT DOOR LOCK AND BODY GROUND) |
Disconnect the D5 main body ECU (network gateway ECU) connector.
Disconnect the F3 front door lock assembly RH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D5-12 (UL2) - F3-5 | Always | Below 1 Ω |
| D5-11 (L2) - F3-6 | Always | Below 1 Ω |
| F3-8 (E) - Body ground | Always | Below 1 Ω |
| D5-12 (UL2) or F3-5 - Body ground | Always | 10 kΩ or higher |
| D5-11 (L2) or F3-6 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||