The battery temperature sensor installed on the battery current sensor assembly detects the battery temperature.
A thermistor is integrated into the battery temperature sensor, and the resistance in the battery temperature sensor changes according to the battery temperature.
The resistance of the thermistor in the battery temperature sensor decreases as the battery temperature increases. The resistance increases as the temperature decreases.
The battery temperature sensor is connected to the ECM. The ECM supplies 5 V from the THB terminal to the battery temperature sensor through resistor R.
The battery temperature sensor and resistor R are connected in series. This results in fluctuations in the voltage supplied from the THB terminal when the resistance changes according to the battery temperature.
The ECM determines the battery temperature according to fluctuations in voltage. When the battery temperature is high, the ECM determines to reduce the amount of current supplied from the generator in order to protect the battery.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P0516 | ·
Engine speed is 500 r/min or more, battery voltage is 10.9 V or more, and 1 second or more have elapsed after starting. ·
Battery temperature sensor output is less than 0.104 V, and duration of the malfunction is 0.5 seconds or more (1-trip detection logic). |
·
Battery current sensor assembly (battery temperature sensor) ·
Short to GND in battery temperature sensor circuit ·
ECM |
| P0517 | ·
Engine speed is 500 r/min or more, battery voltage is 10.9 V or more, and 1 second or more have elapsed after starting. ·
Battery temperature sensor output is more than 4.867 V, and duration of the malfunction is 0.5 seconds or more (1-trip detection logic). |
·
Battery current sensor assembly (battery temperature sensor) ·
Open in battery temperature sensor circuit ·
ECM |
Disconnect the cable from the negative (-) battery terminal.
Disconnect the A11 battery current sensor assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 (THB) - 3 (GND) | 20 to 30°C (68 to 86°F) | 1.5 to 2.6 kΩ |
| *a | Component without harness connected
(Battery Current Sensor Assembly) |
Reconnect the cable to the negative (-) battery terminal.
OK
NG
Disconnect the A33 and A35 ECM connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A33-24 (THB) - A11-2 (THB) | Always | Below 1 Ω |
| A35-30 (EPA2) - A11-3 (GND) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A33-24 (THB) or A11-2 (THB) - Body ground | Always | 10 kΩ or higher |
| A35-30 (EPA2) or A11-3 (GND) - Body ground | Always | 10 kΩ or higher |
OK
NG