The evaporator temperature sensor (No. 1 cooler thermistor) is installed on the No. 1 cooler evaporator sub-assembly in the air conditioner unit to detect the temperature of the air that has passed through the No. 1 cooler evaporator sub-assembly and is used to control the air conditioning. It sends signals to the air conditioning control assembly. The resistance of the evaporator temperature sensor (No. 1 cooler thermistor) changes in accordance with the cooled air temperature that has passed through the No. 1 cooler evaporator sub-assembly. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning control assembly applies voltage (5 V) to the evaporator temperature sensor (No. 1 cooler thermistor) and reads voltage changes as the resistance of the evaporator temperature sensor (No. 1 cooler thermistor) changes. This sensor is used for frost prevention.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1434/23 | Open in evaporator sensor circuit | ·
Evaporator temperature sensor (No. 1 cooler thermistor) ·
Harness or connector between evaporator temperature sensor (No. 1 cooler thermistor) and air conditioning control assembly ·
Air conditioning control assembly |
| B1435/-23 | Short in evaporator sensor circuit | ·
Evaporator temperature sensor (No. 1 cooler thermistor) ·
Harness or connector between evaporator temperature sensor (No. 1 cooler thermistor) and air conditioning control assembly ·
Air conditioning control assembly |
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Evaporator Temp Sensor
(Evap Temp) |
Evaporator temperature sensor (No. 1 cooler thermistor) /
Min.: -82.48°C (-116.46°F) Max.: 153.55°C (308.39°F) |
Actual evaporator temperature displayed | - |
The display is as specified in the normal condition column.
| Result | Proceed to |
|---|---|
| OK (When troubleshooting according to the DTC) | A |
| OK (When troubleshooting according to Problem Symptoms Table) | B |
| NG | C |
A
B
C
Check the DTCs (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)>DTC CHECK / CLEAR)
DTC is not output.
OK
NG
Remove the evaporator temperature sensor (No. 1 cooler thermistor) (See page Vehicle Interior>HEATING / AIR CONDITIONING>FRONT EVAPORATOR TEMPERATURE SENSOR>REMOVAL).
Inspect the evaporator temperature sensor (No. 1 cooler thermistor) (See page Vehicle Interior>HEATING / AIR CONDITIONING>FRONT EVAPORATOR TEMPERATURE SENSOR>INSPECTION)
OK
NG
Disconnect the D20 air conditioning control assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A25-1 - D20-17(TE) | Always | Below 1 Ω |
| A25-2 - D20-6(SG) | Always | Below 1 Ω |
| A25-1 - Body ground | Always | 10 kΩ or higher |
| A25-2 - Body ground | Always | 10 kΩ or higher |
OK
NG