Home › Power Source / Network › FA20 (BATTERY / CHARGING) › CHARGING SYSTEM (for 150 A Type) › from 2019.03
RM2090E _57 Power Source / Network _060693 FA20 BATTERY / CHARGING _0396238 CHARGING SYSTEM(for 150 A Type) C

FA20 BATTERY / CHARGING  CHARGING SYSTEM(for 150 A Type)  U1712  LIN Communication Error with Battery Monitor Module  


DESCRIPTION

The ECM outputs DTC U1712 when the following conditions are met.

DTC No. DTC Detection Condition Trouble Area
U1712 Both of the following conditions are met for 2 seconds:
·

The battery voltage is 10.9 V or more.

·

The information that the ECM receives via LIN communication is not updated or the checksum error is detected.


·

Battery state sensor (battery negative terminal)

·

Wire harness or connector



CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following inspection procedure.


PROCEDURE

1.CHECK FOR DTC
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch ON.


c.

Turn the GTS on.



e.

Turn the ignition switch off and wait at least 30 seconds.


f.

Enter the following menus: Powertrain / Engine / Trouble Codes.



Result:
Result Proceed to
DTC U1712 is output A
DTC is not output B


A

2.CHECK HARNESS AND CONNECTOR

B

2.CHECK HARNESS AND CONNECTOR
a.

Turn the ignition switch off.


b.

Connect the ECM connector properly.

OK:

The connector is securely connected.




OK

3.CHECK HARNESS AND CONNECTOR (BATTERY - BATTERY STATE SENSOR (BATTERY NEGATIVE TERMINAL))

NG

CONNECT THE ENGINE CONTROL COMPUTER CONNECTOR PROPERLY

3.CHECK HARNESS AND CONNECTOR (BATTERY - BATTERY STATE SENSOR (BATTERY NEGATIVE TERMINAL))
a.

Turn the ignition switch off.


b.

Disconnect the ground terminal from the battery state sensor (battery negative terminal).


c.

Disconnect the connector from the battery state sensor (battery negative terminal).


d.

Disconnect the battery positive terminal.


e.

Measure the resistance of the harness between the positive terminal of the battery cable and the battery state sensor (battery negative terminal) connector.

Standard Resistance:
Tester Connection Condition Specified Condition
Battery positive (+) terminal - A78-1 (+B) Always Below 1 Ω




OK

4.CHECK HARNESS AND CONNECTOR (ECM - BATTERY STATE SENSOR (BATTERY NEGATIVE TERMINAL))

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.CHECK HARNESS AND CONNECTOR (ECM - BATTERY STATE SENSOR (BATTERY NEGATIVE TERMINAL))
a.

Turn the ignition switch off.


b.

Disconnect the ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A78-2 (LIN) - A33-21 (LIN) Always Below 1 Ω




OK

REPLACE BATTERY STATE SENSOR (BATTERY NAGATIVE TERMINAL)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR