The door lock control receives a door lock / unlock signal from the driver side door lock assembly.
Connect the GTS or Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the GTS or Techstream on.
Enter the following menus: Body Electrical / Body / Data List.
Read the display on the GTS or Techstream.
| Tester Display | Measurement Item | Range | Normal Condition | Tester Display |
|---|---|---|---|---|
| Lock SW | Front door lock assembly RH*1 or LH*2 lock signal | ON or OFF | ON: Driver side door locked
OFF: Driver side door unlocked |
- |
| Unlock SW | Front door lock assembly RH*1 or LH*2 unlock signal | ON or OFF | ON: Driver side door unlocked
OFF: Driver side door locked |
- |
*1:for RHD
*2:for LHD
Normal conditions listed above are displayed.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the front door lock assembly RH*1 or LH*2.
Click hereVehicle Interior>DOOR LOCK>FRONT DOOR LOCK>REMOVAL
Inspect the front door lock assembly RH*1 or LH*2.
Click hereVehicle Interior>DOOR LOCK>FRONT DOOR LOCK>INSPECTION
*1: for RHD
*2: for LHD
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the 3G main body ECU (fuse block assembly) connector.
Disconnect the F5*1 or G10*2 front door lock assembly RH*1 or LH*2 connector.
*1: for RHD
*2: for LHD
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3G-14 - F5-2 (UKS) | Always | Below 1 Ω |
| 3G-13 - F5-6 (LKS) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3G-14 - G10-3 (UKS) | Always | Below 1 Ω |
| 3G-13 - G10-1 (LKS) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3G-14 or F5-2 (UKS) - Body ground | Always | 10 kΩ or higher |
| 3G-13 or F5-6 (LKS) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3G-14 or G10-3 (UKS) - Body ground | Always | 10 kΩ or higher |
| 3G-13 or G10-1 (LKS) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F5*1 or G10*2 front door lock assembly RH*1 or LH*2 connector.
*1: for RHD
*2: for LHD
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F5-1 (E) - Body ground | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G10-2 (E) - Body ground | Always | Below 1 Ω |
| Result | Proceed to |
|---|---|
| OK (for RHD) | A |
| OK (for LHD) | B |
| NG | C |
A
B
C