2ZR-FXE HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM(for NICKEL METAL HYDRIDE BATTERY)  P312387  Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message  


DESCRIPTION

For a description of the inverter.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>MOTOR GENERATOR CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY)>P0D2D16

The MG ECU, which is built into in the inverter with converter assembly, controls motor (MG2) based on commands from the hybrid vehicle control ECU. The MG ECU monitors communication data and detects malfunctions.

The hybrid vehicle control ECU monitors communication data and detects malfunctions.

A communication error between the MG ECU and the hybrid vehicle control ECU.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P312387 Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message Error in reception from inverter with converter assembly (MG ECU) via serial communication (out of communication standard)
(1 trip detection logic)
·

Wire harness or connector

·

Inverter with converter assembly

·

Hybrid vehicle control ECU

·

PCU FR fuse


Does not come on Master Warning:
Comes on

CONFIRMATION DRIVING PATTERN

HINT:

After repairs have been completed, clear the DTCs and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY)>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for 2 minutes or more.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

With power switch on (IG) and wait for 2 minutes or more.

7.

Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.

8.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.




CAUTION / NOTICE / HINT

CAUTION:
·
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the HV battery



·
A371653

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.


·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.


·
A371654C01
1.563,1.229 1.333,0.813 true 1.156,0.677 1.469,0.875 0.313,0.198 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>MOTOR GENERATOR CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY)>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


PROCEDURE

1.INSPECT FUSE (PCU FR)
a.

Remove the PCU FR fuse from the No. 1 engine room relay block.


b.
A389522C01
2.667,1.917 1.75,1.531 true 0.354,0.094 0.667,0.25 0.313,0.156 10 false *1 2.74,1.896 3.052,2.052 0.313,0.156 10 false *2
*1 No. 1 Engine Room Relay Block
*2 PCU FR Fuse


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
PCU FR fuse terminals Always Below 1 Ω



c.

Install the PCU FR fuse.


Result:
Proceed to
OK
NG



OK

2.CLEAR DTC

NG

9.REPLACE FUSE (PCU FR)
2.CLEAR DTC

NEXT

3.CHECK DIAGNOSIS RELATED INFORMATION AND DTC OUTPUT (HYBRID CONTROL)
3.CHECK DIAGNOSIS RELATED INFORMATION AND DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG) and wait for 2 minutes or more.


c.

Enter the following menus: Powertrain / Hybrid Control / Utility / Diagnosis Related Information.

Powertrain > Hybrid Control > Utility
Tester Display
Diagnosis Related Information
50005 397 56

d.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

Powertrain > Hybrid Control > Trouble Codes
50001 397

e.

Check for DTCs.

Result:
Result Proceed to
P312387 is listed in Diagnosis Related Information or DTC P312387 is output. A
P312387 is not listed in Diagnosis Information and DTC P312387 is not output. B



f.

Turn the power switch off.



A

4.CHECK CONNECTOR CONNECTION CONDITION (HYBRID VEHICLE CONTROL ECU CONNECTOR)

B

4.CHECK CONNECTOR CONNECTION CONDITION (HYBRID VEHICLE CONTROL ECU CONNECTOR)
a.

Check the connector connections and contact pressure of the relevant terminals for the hybrid vehicle control ECU connectors.

HINT:

Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>ELECTRONIC CIRCUIT INSPECTION PROCEDURE


A394800C02
0.042,0.125 0.271,0.313 0.229,0.188 12 true *A 3.594,0.135 3.875,0.406 0.281,0.271 12 false *B
*A for LHD *B for RHD


OK:

The connectors are connected securely and there are no contact pressure problems.



Result:
Proceed to
OK
NG



OK

5.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

NG

CONNECT SECURELY

5.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
A376627

Check the connection condition of the low voltage connectors of the inverter with converter assembly and the contact pressure of each terminal. Check the terminals for deformation, and the connector for water and foreign matter.

HINT:

Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>ELECTRONIC CIRCUIT INSPECTION PROCEDURE


NOTICE:

Before disconnecting the connector, confirm that it is properly connected by checking that the claws of the lock levers are engaged and that the connector cannot be pulled off.


OK:

- The connector is connected securely.

- The terminals are not deformed and are connected securely.

- No water or foreign matter in the connector.


HINT:

When connecting the connector, connect it with the lock levers raised. Rotate each lock lever downward and make sure that the connector is securely connected. When a lock lever is fully lowered, a click will be heard as its claw engages. After the click is heard, pull up on the connector to confirm that it is securely connected.


Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C




A

6.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY POWER SOURCE CIRCUIT)

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

6.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY POWER SOURCE CIRCUIT)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the inverter with converter assembly connector.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>INVERTER WITH CONVERTER>REMOVAL


c.
A365593C07
0.292,0.906 0.667,1.167 0.375,0.26 2.042,0.917 2.604,0.302 true 1.906,0.906 1.906,0.292 true 2.031,1.25 2.719,1.833 true 1.906,1.25 1.917,1.833 true 0.115,0.125 0.427,0.323 0.313,0.198 10 false *a 0.365,0.948 0.823,1.146 0.458,0.198 10 false C65 2.51,0.094 2.823,0.292 0.313,0.198 10 false +B 1.76,0.104 2.219,0.302 0.458,0.198 10 false +B2 2.563,1.865 3.021,2.063 0.458,0.198 10 false GND1 1.823,1.865 2.438,2.063 0.615,0.198 10 false GND2
*a Front view of wire harness connector
(to Inverter with Converter Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C65-24 (GND1) - Body ground Power switch off Below 1 Ω
C65-23 (GND2) - Body ground Power switch off Below 1 Ω



d.

Connect the cable to the negative (-) auxiliary battery terminal and wait for 2 minutes or more.


e.

Turn the power switch on (IG).


f.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
C65-6 (+B) - Body ground Power switch on (IG) 11 to 14 V
C65-5 (+B2) - Body ground Power switch on (IG) 11 to 14 V


NOTICE:

Turning the power switch on (IG) with the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.



g.

Turn the power switch off.


h.

Disconnect the cable from the negative (-) auxiliary battery terminal.


i.

Reconnect the inverter with converter assembly connector.


Result:
Proceed to
OK
NG



OK

7.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - HYBRID VEHICLE CONTROL ECU)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

7.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - HYBRID VEHICLE CONTROL ECU)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the inverter with converter assembly connector.


c.

Disconnect the hybrid vehicle control ECU connector.


d.

Connect the cable to the negative (-) auxiliary battery terminal.


e.

Turn the power switch on (IG).


f.
A389523C01
0.333,0.833 0.833,1.083 0.5,0.25 1.177,2.271 1.677,2.521 0.5,0.25 0.833,1.667 1.375,1.396 true 2,4.417 1.604,4.198 true 1.531,4.208 1.083,4.417 true 2,2 1.542,1.396 true 0.167,0.177 0.479,0.333 0.313,0.156 10 false *a 0.188,2.167 0.5,2.323 0.313,0.156 10 false *b 0.531,1.688 1.094,1.844 0.563,0.156 10 false HMCL 1.844,2.031 2.406,2.188 0.563,0.156 10 false HMCH 0.792,4.448 1.354,4.604 0.563,0.156 10 false HMCH 1.906,4.438 2.469,4.594 0.563,0.156 10 false HMCL 0.458,0.865 0.76,1.052 0.302,0.188 10 false C65 1.302,2.302 1.604,2.49 0.302,0.188 10 false A48
*a Front view of wire harness connector
(to Inverter with Converter Assembly)
*b Rear view of wire harness connector
(to Hybrid Vehicle Control ECU)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A48-30 (HMCL) - Body ground Power switch on (IG) Below 1 V
A48-31 (HMCH) - Body ground Power switch on (IG) Below 1 V


NOTICE:

Turning the power switch on (IG) with the hybrid vehicle control ECU connector and the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.



g.

Turn the power switch off.


h.

Disconnect the cable from the negative (-) auxiliary battery terminal and wait for 2 minutes or more.


i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance (Check for Open):
Tester Connection Condition Specified Condition
C65-19 (HMCL) - A48-30 (HMCL) Power switch off Below 1 Ω
C65-20 (HMCH) - A48-31 (HMCH) Power switch off Below 1 Ω


Standard Resistance (Check for Short):
Tester Connection Condition Specified Condition
C65-19 (HMCL) or A48-30 (HMCL) - Body ground and other terminals Power switch off 10 kΩ or higher
C65-20 (HMCH) or A48-31 (HMCH) - Body ground and other terminals Power switch off 10 kΩ or higher


HINT:

As there might be an intermittent malfunction, inspect the following items even if the measured resistance is as specified.

Check that each connector between the inverter with converter assembly and hybrid vehicle control ECU is not loose or disconnected.



j.

Reconnect the hybrid vehicle control ECU connector.


k.

Reconnect the inverter with converter assembly connector.


Result:
Proceed to
OK
NG



OK

8.CHECK INVERTER WITH CONVERTER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

8.CHECK INVERTER WITH CONVERTER ASSEMBLY
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the C65 inverter with converter assembly connector.


c.
A389500C13
1.156,0.969 1.667,1.219 0.51,0.25 1.25,2.417 1.521,1.917 true 1.833,2.417 1.583,1.917 true 0.167,0.177 0.479,0.333 0.313,0.156 10 false *a 1.052,2.448 1.635,2.615 0.583,0.167 10 false HMCH 1.74,2.448 2.302,2.615 0.563,0.167 10 false HMCL 1.281,1 1.615,1.219 0.333,0.219 10 false A48
*a Component with harness connected
(Hybrid Vehicle Control ECU)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A48-30 (HMCL) -A48-31 (HMCH) Power switch off 110 to 130 Ω



d.

Reconnect the C65 inverter with converter assembly connector.


Result:
Proceed to
OK
NG



OK

NG

9.REPLACE FUSE (PCU FR)
a.
A389522C01
2.667,1.917 1.75,1.531 true 0.354,0.094 0.667,0.25 0.313,0.156 10 false *1 2.74,1.896 3.052,2.052 0.313,0.156 10 false *2
*1 No. 1 Engine Room Relay Block
*2 PCU FR Fuse


Replace the PCU FR fuse.


b.

Turn the power switch on (READY).


c.

Check if there is an open circuit in the PCU FR fuse in the No. 1 engine room relay block.

OK:

There is no open circuit in the PCU FR fuse.


HINT:

If the fuse does not become open again after turning the power switch on (READY), it can be assumed that the previous fuse failed due to age.



d.

Turn the power switch off.


Result:
Proceed to
OK
NG



OK

COMPLETED

NG

10.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - PCU FR FUSE)
10.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - PCU FR FUSE)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the PCU FR fuse from the No. 1 engine room relay block.


c.

Disconnect the inverter with converter assembly connector.


d.

Measure the resistance according to the value(s) in the table below.

A389524C02
4.385,1.25 4.885,1.5 0.5,0.25 5.646,1.25 5.167,0.417 true 5.781,1.229 6.25,0.417 true 0.438,0.073 0.75,0.229 0.313,0.156 10 false *1 4.865,0.323 5.354,0.49 0.49,0.167 10 false +B2 4.521,0.083 4.833,0.24 0.313,0.156 10 false *a 2.323,0.906 2.635,1.063 0.313,0.156 10 false *b 6.333,0.313 6.823,0.479 0.49,0.167 10 false +B 4.5,1.281 4.813,1.479 0.313,0.198 10 false C65
*1 No. 1 Engine Room Relay Block - -
*a Front view of wire harness connector
(to Inverter with Converter Assembly)
*b PCU FR Fuse Holder


Standard Resistance (Check for Short):
Tester Connection Condition Specified Condition
C65-6 (+B), C65-5 (+B2) or 2 (PCU FR fuse holder) - Body ground and other terminals Power switch off 10 kΩ or higher



e.

Reconnect the inverter with converter assembly connector.


f.

Install the PCU FR fuse.


Result:
Proceed to
OK
NG



OK

11.REPLACE INVERTER WITH CONVERTER ASSEMBLY

NG

12.REPAIR OR REPLACE HARNESS OR CONNECTOR
11.REPLACE INVERTER WITH CONVERTER ASSEMBLY

NEXT

REPLACE FUSE (PCU FR)

12.REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
Proceed to
NEXT



NEXT