Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM › from 2019.09
RM32K0E _58 Vehicle Interior _061609 HEATING / AIR CONDITIONING _0300711 AIR CONDITIONING SYSTEM C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  B1442  Air Inlet Damper Control Servo Motor Circuit  


DESCRIPTION

The No. 1 blower damper servo sub-assembly sends pulse signals to inform the air conditioning amplifier assembly of the damper position. The air conditioning amplifier assembly activates the motor (normal or reverse) based on these signals to move the air inlet damper to the appropriate position to change the air inlet mode (fresh, recirculation/fresh, and recirculation).

The air conditioning amplifier assembly communicates with the servo through a communication/driver IC and wiring assembly called the air conditioning harness assembly.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory
B1442 Air Inlet Damper Control Servo Motor Circuit Air inlet damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 blower damper servo sub-assembly
·

No. 1 blower damper servo sub-assembly

·

No. 1 air conditioning radiator damper servo sub-assembly

·

Air conditioning harness assembly

·

Air conditioning amplifier assembly

·

Blower assembly


Memorized
(30 seconds or more)*

*: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.


CAUTION / NOTICE / HINT

HINT:
·

Confirm that no mechanical problem is present because this DTC can be output when either a damper link or damper is mechanically locked.

·

When installing the damper servo motor, make sure to install it correctly.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>BLOWER UNIT>REASSEMBLY



PROCEDURE

1.CHECK FOR DTC
a.

Check for DTCs.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM>DTC CHECK / CLEAR

Body Electrical > Air Conditioner > Trouble Codes
50001 121

Result:
Result Proceed to
DTC B1497 is output A
DTC B1441, B1442, B1443 and B1446 are output B
DTC B1442 is output C



A

B

REPLACE NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY

C

2.INSPECT BLOWER ASSEMBLY
2.INSPECT BLOWER ASSEMBLY
a.

Remove the No. 1 blower damper servo sub-assembly.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>BLOWER UNIT>DISASSEMBLY


b.

Operate the air inlet control dampers by hand.

OK:

The air inlet control dampers are easily operated by hand.



Result:
Proceed to
OK
NG



OK

3.INSPECT AIR CONDITIONING HARNESS ASSEMBLY

NG

3.INSPECT AIR CONDITIONING HARNESS ASSEMBLY
a.

Disconnect the f2 No. 1 air conditioning radiator damper servo sub-assembly connector.


b.

Disconnect the f4 No. 1 blower damper servo sub-assembly connector.


c.

Measure the resistance according to the value (s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
f2-1 - f4-5 Always Below 1 Ω
f2-2 - f4-4 Always Below 1 Ω
f2-3 - f4-3 Always Below 1 Ω
f2-4 - f4-2 Always Below 1 Ω
f2-5 - f4-1 Always Below 1 Ω
f2-1 or f4-5 - Body ground Always 10 kΩ or higher
f2-2 or f4-4 - Body ground Always 10 kΩ or higher
f2-3 or f4-3 - Body ground Always 10 kΩ or higher
f2-4 or f4-2 - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

4.PERFORM ACTIVE TEST USING GTS (AIR INLET DAMPER TARG PULSE)

NG

REPLACE AIR CONDITIONING HARNESS ASSEMBLY

4.PERFORM ACTIVE TEST USING GTS (AIR INLET DAMPER TARG PULSE)
a.

Reconnect the f2 No. 1 air conditioning radiator damper servo sub-assembly connector.


b.

Reconnect the f4 No. 1 blower damper servo sub-assembly connector.


c.

Connect the GTS to the DLC3.


d.

Turn the ignition switch to ON.


e.

Turn the GTS on.


f.

Enter the following menus: Body Electrical / Air Conditioner / Active test.


g.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 220 to 256 pulses
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Inlet Damper Targ Pulse
50004 121 27
OK:

No. 1 blower damper servo sub-assembly pulse operates smoothly.



Result:
Result Proceed to
No. 1 blower damper servo sub-assembly pulse are malfunctioning A
No. 1 blower damper servo sub-assembly pulse is normal B



A

5.CHECK HARNESS AND CONNECTOR (NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY - BODY GROUND)

B

7.INSPECT NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY
5.CHECK HARNESS AND CONNECTOR (NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY - BODY GROUND)
a.

Disconnect the f4 No. 1 blower damper servo sub-assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
f4-1 - Body ground Always Below 1 Ω



Result:
Proceed to
OK
NG



OK

6.INSPECT NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY

NG

REPLACE NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY

6.INSPECT NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY
a.
E361470C13
1.625,0.635 2.125,0.885 0.5,0.25 0.208,0.25 0.521,0.448 0.313,0.198 10 false *a 1.823,0.667 2.135,0.865 0.313,0.198 10 false f4
*a Component with harness connected
(No. 1 Blower Damper Servo Sub-assembly)


Measure the voltage according to the value(s) in the table below.

Tester Connection Condition Specified Condition
f4-4 - Body ground
·

Ignition switch ON

·

No. 1 blower damper servo sub-assembly operating (fresh)


11 to 14 V ←→ Below 1 V
f4-5 - Body ground
·

Ignition switch ON

·

No. 1 blower damper servo sub-assembly operating (recirculation)


11 to 14 V ←→ Below 1 V


Result:
Proceed to
OK
NG



OK

REPLACE NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY

NG

REPLACE NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY

7.INSPECT NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY
a.
E361470C13
1.625,0.635 2.125,0.885 0.5,0.25 0.208,0.25 0.521,0.448 0.313,0.198 10 false *a 1.823,0.667 2.135,0.865 0.313,0.198 10 false f4
*a Component with harness connected
(No. 1 Blower Damper Servo Sub-assembly)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
f4-2 - Body ground Ignition switch ON 4.75 V to 5.25 V
f4-3 - Body ground Ignition switch ON 4.75 V to 5.25 V



Result:
Proceed to
OK
NG



OK

8.INSPECT NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY

NG

REPLACE NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY

8.INSPECT NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY
a.

Turn the ignition switch ON.


b.
E361467C09
2.885,0.313 3.385,0.563 0.5,0.25 0.073,0.146 0.385,0.344 0.313,0.198 10 false *a 0.313,2.031 0.625,2.229 0.313,0.198 10 false *b 0.333,3.396 0.646,3.594 0.313,0.198 10 false *c 0.51,4.167 0.823,4.365 0.313,0.198 10 false GND 0.521,2.844 0.833,3.042 0.313,0.198 10 false GND 3.073,0.344 3.292,0.542 0.219,0.198 10 false f4
*a Component with harness connected
(No. 1 blower damper servo sub-assembly)
*b Fresh waveform
*c Recirculation waveform


Connect an oscilloscope to terminals f4-2 and f4-3 of the air conditioning amplifier assembly and check the waveform.

OK:

Waveform is similar to that shown in the illustration.


Item Content
Tool Setting 2.5 V/DIV., 200 ms./DIV.
Vehicle Condition
·

Ignition switch ON

·

No. 1 blower damper servo sub-assembly operating




Result:
Proceed to
OK
NG



OK

REPLACE NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY

NG

REPLACE NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY