Home › Engine / Hybrid System › M20A-FXS (HYBRID / BATTERY CONTROL) › INVERTER WITH CONVERTER › from 2020.08
RM32K0E _51 Engine / Hybrid System _083959 M20A-FXS HYBRID / BATTERY CONTROL _0404415 INVERTER WITH CONVERTER A

M20A-FXS HYBRID / BATTERY CONTROL  INVERTER WITH CONVERTER  INSTALLATION  


PROCEDURE

Hide G921E 1.INSTALL INVERTER PROTECTOR

a.
A406200C02
1.198,1.5 0.948,1.5 0.948,1.5 0.677,0.917 true 1.24,1.427 1.552,1.583 0.313,0.156 10 false *a
*a Pin


Install the inverter protector to the inverter with converter assembly with the bolt.

Torque:
9.5 N*m (97 kgf*cm, 84 in.*lbf)

NOTICE:

Make sure to align the hole of the inverter protector with the pin.



Hide 2.INSTALL WIRE HARNESS CLAMP BRACKET

a.

Install the wire harness clamp bracket to the inverter with converter assembly with the 2 bolts.

Torque:
10 N*m (102 kgf*cm, 7 ft.*lbf)


b.

Install the wire harness clamp bracket to the inverter with converter assembly with the bolt.

Torque:
10 N*m (102 kgf*cm, 7 ft.*lbf)


c.
A443766C01
1.375,1.74 1.531,1.938 0.156,0.198 10 true 1 1.885,1.458 2.042,1.656 0.156,0.198 10 true 2

Install the wire harness clamp bracket to the inverter with converter assembly with the 2 bolts.

Torque:
9.5 N*m (97 kgf*cm, 84 in.*lbf)


Hide 33829E 3.INSTALL TRANSMISSION CONTROL CABLE SUPPORT

a.

Install the transmission control cable support to the inverter with converter assembly with the bolt.

Torque:
9.5 N*m (97 kgf*cm, 84 in.*lbf)


Hide G9215 4.INSTALL NO. 2 INVERTER BRACKET

NOTICE:
A443762C01
0.875,1.094 1.75,1.958 1.75,1.958 2.396,1.135 true 0.135,0.125 0.448,0.281 0.313,0.156 10 false *a 1.698,1.99 2.01,2.146 0.313,0.156 10 false *b
*a Bottom of Inverter with Converter Assembly
*b Support


Make sure to support the inverter with converter assembly at the positions shown in the illustration, otherwise it may be damaged.


a.
A443764C02
2.271,1.969 2.927,1.802 2.927,1.802 2.635,1.76 false 2.948,1.698 3.26,1.896 0.313,0.198 10 false *a 0.448,1.188 0.656,1.396 0.208,0.208 10 false 1 1.438,1.458 1.615,1.646 0.177,0.188 10 true 2
*a Wooden Block


Set the inverter with converter assembly on wooden blocks.


b.

Temporarily install the No. 2 inverter bracket to the inverter with converter assembly with the 2 bolts.


c.

Fully tighten the 2 bolts in the order shown in the illustration.

Torque:
15 N*m (153 kgf*cm, 11 ft.*lbf)


Hide G9214 5.INSTALL NO. 1 INVERTER BRACKET

a.
A443763C02
2.146,2 2.865,1.958 2.865,1.958 2.573,1.802 false 2.875,1.844 3.188,2.042 0.313,0.198 10 false *a 0.51,1.021 0.719,1.229 0.208,0.208 10 false 1 1.427,1.448 1.604,1.635 0.177,0.188 10 true 2
*a Wooden Block


Temporarily install the No. 1 inverter bracket to the inverter with converter assembly with the 2 bolts.


b.

Fully tighten the 2 bolts in the order shown in the illustration.

Torque:
15 N*m (153 kgf*cm, 11 ft.*lbf)


Hide G9200 6.INSTALL INVERTER WITH CONVERTER ASSEMBLY

CAUTION:

Be sure to wear insulated gloves.


a.

Temporarily install the inverter with converter assembly with the 5 bolts and 2 nuts.

NOTICE:
·

When installing the inverter with converter assembly, be careful not to damage the parts around it.

·

To prevent damage, do not hold the inverter with converter assembly by the connectors, brackets or cooling pipes.

·

To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.

·
A443770C01
0.469,2.208 0.667,2.417 0.198,0.208 10 true *a 0.479,3.406 0.677,3.615 0.198,0.208 10 true *b
*a Correct
*b Incorrect


Make sure that the inverter with converter assembly is positioned so that the stud bolts are in contact with the base of the U-shaped portions of the No. 1 inverter bracket.



HINT:

If the bolts and nuts are not tightened appropriately, the inverter with converter assembly may make an abnormal noise.



b.

Fully tighten the bolt (A).

A443761N01
1.396,1.323 1.552,1.521 0.156,0.198 10 true A 2.177,1.354 2.333,1.552 0.156,0.198 10 true B 2.427,1.24 2.583,1.438 0.156,0.198 10 true B 2.625,0.896 2.781,1.094 0.156,0.198 10 true B 5.385,2.5 5.542,2.698 0.156,0.198 10 true C 4.094,2.479 4.25,2.677 0.156,0.198 10 true D 4.688,2.521 4.823,2.729 0.135,0.208 10 true D

Torque:
55 N*m (561 kgf*cm, 41 ft.*lbf)


c.

Fully tighten the 3 bolts (B).

Torque:
55 N*m (561 kgf*cm, 41 ft.*lbf)


d.

Fully tighten the bolt (C).

Torque:
55 N*m (561 kgf*cm, 41 ft.*lbf)


e.

Fully tighten the 2 nuts (D).

Torque:
55 N*m (561 kgf*cm, 41 ft.*lbf)


Hide G1148 7.CONNECT MOTOR CABLE

CAUTION:

Be sure to wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


a.

Temporarily connect the motor cable to the inverter with converter assembly with the 4 bolts.

NOTICE:
·

Do not touch the waterproof seal or terminals of the connector.

·

Do not damage the terminals, connector housing or inverter with converter assembly during connection.




b.
A443759C02
0.896,0.188 1.208,0.188 1.208,0.188 1.594,0.542 true 0.729,0.094 1.042,0.292 0.313,0.198 10 false *a 3.177,1.677 3.333,1.875 0.156,0.198 10 true A 0.302,1.813 0.479,2 0.177,0.188 10 true 2 0.604,2.719 0.792,2.917 0.188,0.198 10 true 1 2.865,2.469 3.031,2.656 0.167,0.188 10 true 3
*a Waterproof Seal


Fully tighten the bolt (A).

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


c.

Fully tighten the 3 bolts in the order shown in the illustration to connect the motor cable to the inverter with converter assembly.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


d.
A443758

Temporarily install the 6 bolts.

NOTICE:
·

To prevent the threads from being damaged, temporarily tighten the 6 bolts by hand.

·

Do not damage the terminals, connector housing or inverter with converter assembly during connection.




e.

Using an insulated tool, fully tighten the 6 bolts.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)

NOTICE:
·

Do not touch the waterproof seal or terminals of the connector.

·

Do not damage the terminals, connector housing or inverter with converter assembly during connection.

·

Be sure to use a torque wrench to tighten the bolts.




Hide G9221 8.INSTALL INVERTER COVER

CAUTION:

Wear insulated gloves.


a.

Install the inverter cover to the inverter with converter assembly with the 2 bolts.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)

NOTICE:
·

Visually confirm that the inverter cover waterproof seal is securely installed before installing the inverter cover.

·

Do not touch the waterproof seal of the inverter cover.

·

Make sure that the interlock is fully engaged.

·

Do not damage the terminals, interlock connector or inverter with converter assembly during installation.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·
A376320C03
2.167,2.115 2.656,1.635 2.656,1.635 2.031,1.24 false 1.031,0.313 1.302,0.313 1.302,0.313 1.823,0.781 true 0.865,0.188 1.177,0.385 0.313,0.198 10 false *a 2.698,1.521 3.01,1.719 0.313,0.198 10 false *1
*1 Inverter Cover
*a Screw


Do not remove or excessively tighten the screw of the inverter cover.

·

Although the inverter cover may feel loose, this is not due to a malfunction.

·
A434991C02
1.458,1.688 1.688,1.875 0.229,0.188 10 true *a
*a No Gap


Push in the inverter cover until it contacts the inverter with converter assembly.




Hide 17771A 9.INSTALL AIR CLEANER BRACKET

a.

Install the air cleaner bracket with the bolt.

Torque:
7.0 N*m (71 kgf*cm, 62 in.*lbf)


b.

Engage the clamp.


Hide G922AA 10.CONNECT INLET NO. 1 INVERTER COOLING HOSE

a.
A443771C01
0.385,0.542 0.625,0.542 0.625,0.542 0.76,0.948 true 0.885,0.365 1.125,0.365 1.125,0.365 1.292,0.948 true 0.229,0.427 0.542,0.625 0.313,0.198 10 false *a 0.719,0.26 1.031,0.458 0.313,0.198 10 false *b 1.083,1.5 1.396,1.698 0.313,0.198 10 false *c 2.396,0.104 2.708,0.302 0.313,0.198 10 false *d 3.115,0.854 3.427,1.052 0.313,0.198 10 false *e 2.813,0.375 3.198,0.615 0.385,0.24 10 false 270°
*a Alignment Mark (Yellow)
*b Alignment Mark of Pipe
*c 2 to 6 mm (0.0787 to 0.236 in.)
*d Up
*e LH Side


Connect the inlet No. 1 inverter cooling hose to the inverter with converter assembly and slide the clip to secure it.

NOTICE:
·

To prevent foreign matter from entering the inverter with converter assembly and inverter cooling system, do not remove the pieces of cloth from the pipe and disconnected hose until installation.

·

Make sure to align the alignment mark of the hose with the alignment mark of the pipe of the inverter with converter assembly.



HINT:

Make sure that the clip is positioned as shown in the illustration.



Hide G922C 11.CONNECT OUTLET NO. 1 INVERTER COOLING HOSE

a.
A443772C01
0.719,0.594 0.635,0.229 0.635,0.229 0.448,0.229 true 1.302,0.594 1.219,0.229 1.219,0.229 1.031,0.229 true 0.292,0.125 0.604,0.323 0.313,0.198 10 false *a 0.865,0.135 1.177,0.333 0.313,0.198 10 false *b 1.083,1.156 1.396,1.354 0.313,0.198 10 false *c
*a Alignment Mark (Yellow)
*b Rib
*c 2 to 6 mm (0.0787 to 0.236 in.)


Connect the outlet No. 1 inverter cooling hose assembly to the inverter with converter assembly and slide the clip to secure it.

NOTICE:
·

To prevent foreign matter from entering the inverter with converter assembly and inverter cooling system, do not remove the pieces of cloth from the pipe and disconnected hose until installation.

·

Make sure to align the alignment mark of the hose with the rib of the inverter with converter assembly.




Hide 82121 12.CONNECT ENGINE WIRE

CAUTION:

Be sure to wear insulated gloves.


a.

Engage the clamp and connect the engine wire to the inverter with converter assembly.

A443752


b.

Install the 2 nuts.

Torque:
10 N*m (102 kgf*cm, 7 ft.*lbf)


c.
A443751

Engage the 2 clamps.


d.

Temporarily install the nut.

NOTICE:

To prevent the threads from being damaged, temporarily tighten the nut by hand.



e.

Fully tighten the nut.

Torque:
10 N*m (102 kgf*cm, 7 ft.*lbf)


f.

Engage the 2 claws to close the engine wire terminal cover.


g.
A443749

Connect the engine wire to the inverter with converter assembly with the bolt.

Torque:
10 N*m (102 kgf*cm, 7 ft.*lbf)


h.
A443748

Connect the engine wire to the inverter with converter assembly with the bolt.

Torque:
10 N*m (102 kgf*cm, 7 ft.*lbf)


i.
A443747

Engage the 2 claws to connect the engine wire to the No. 1 engine room relay block.


j.

Connect the 3 No. 1 engine room relay block connectors.


k.
A443746

Install the No. 1 relay block cover to the No. 1 engine room relay block.


Hide 13.INSTALL WIRE HARNESS CLAMP BRACKET

CAUTION:

Be sure to wear insulated gloves.


a.

Install the wire harness clamp bracket to the inverter with converter assembly with the nut.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


Hide 821H2 14.CONNECT HV AIR CONDITIONING WIRE

CAUTION:

Be sure to wear insulated gloves.


a.

Engage the clamp.


b.
A443773

Connect the HV air conditioning wire to the inverter with converter assembly and install the 2 bolts.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)

NOTICE:
·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

Do not touch the waterproof seal or terminals of the connector.

·

Do not damage the terminals, connector housing or inverter with converter assembly when connecting the connector.




Hide 821H1 15.CONNECT FLOOR UNDER WIRE

CAUTION:

Be sure to wear insulated gloves.


a.

Engage the 2 clamps.


b.
A443774

Connect the HV floor under wire to the inverter with converter assembly and install the 2 bolts.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)

NOTICE:
·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

Do not touch the waterproof seal or terminals of the connector.

·

Do not damage the terminals, connector housing or inverter with converter assembly when connecting the connector.




Hide 82121 16.CONNECT ENGINE WIRE

CAUTION:

Be sure to wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


a.
A443775

Connect the 2 inverter with converter assembly connectors move the lock lever as shown in the illustration.

NOTICE:
·

To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.

·

Do not damage the terminals, connector housing or inverter with converter assembly when connecting the connectors.

·

Do not touch the waterproof seal or terminals of the connectors.




Hide 33820B 17.CONNECT TRANSMISSION CONTROL CABLE ASSEMBLY

a.

Engage the 2 clamps.


b.

Install the bolt to connect the transmission control cable assembly.

Torque:
12 N*m (122 kgf*cm, 9 ft.*lbf)


Hide 17701 18.INSTALL AIR CLEANER CASE SUB-ASSEMBLY

a.

Install the air cleaner case sub-assembly with the 3 bolts.

Torque:
4.0 N*m (41 kgf*cm, 35 in.*lbf)


Hide 17801 19.INSTALL AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY

Hide 20.INSTALL AIR CLEANER CAP WITH AIR CLEANER HOSE

Hide 23.ADD COOLANT (for Inverter)

Hide 51444A 25.INSTALL REAR ENGINE UNDER COVER LH