The No. 1 blower damper servo sub-assembly sends pulse signals to inform the air conditioning amplifier assembly of the damper position. The air conditioning amplifier assembly activates the motor (normal or reverse) based on these signals to move the air inlet damper to the appropriate position to change the air inlet mode (fresh, recirculation/fresh, and recirculation).
The air conditioning amplifier assembly communicates with the servo through a communication/driver IC and wiring assembly called the air conditioning harness assembly.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1442 | Air Inlet Damper Control Servo Motor Circuit | Air inlet damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 blower damper servo sub-assembly | ·
No. 1 blower damper servo sub-assembly ·
No. 1 air conditioning radiator damper servo sub-assembly ·
Air conditioning harness assembly ·
Air conditioning amplifier assembly ·
Blower assembly |
Memorized
(30 seconds or more)* |
*: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.
Confirm that no mechanical problem is present because this DTC can be output when either a damper link or damper is mechanically locked.
When installing the damper servo motor, make sure to install it correctly.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>BLOWER UNIT (for DENSO Made)>REASSEMBLY
Check for DTCs.
| Result | Proceed to |
|---|---|
| DTC B1497 is output | A |
| DTC B1441, B1442, B1443 and B1446 are output | B |
| DTC B1442 is output | C |
A
B
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING UNIT (for DENSO Made)>DISASSEMBLY
C
Remove the No. 1 blower damper servo sub-assembly.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>BLOWER UNIT (for DENSO Made)>DISASSEMBLY
Operate the air inlet control dampers by hand.
The air inlet control dampers are easily operated by hand.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the No. 1 air conditioning radiator damper servo sub-assembly connector.
Disconnect the No. 1 blower damper servo sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 6 (STE2) - 3 (sigB) | Always | Below 1 Ω |
| 5 (STE1) - 2 (sigA) | Always | Below 1 Ω |
| 8 (M-) - 5 (M-) | Always | Below 1 Ω |
| 7 (M+) - 4 (M+) | Always | Below 1 Ω |
| 4 (GND) - 1 (GND) | Always | Below 1 Ω |
| 6 (STE2) or 3 (sigB) - Body ground | Always | 10 kΩ or higher |
| 5 (STE1) or 2 (sigA) - Body ground | Always | 10 kΩ or higher |
| 8 (M-) or 5 (M-) - Body ground | Always | 10 kΩ or higher |
| 7 (M+) or 4 (M+) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING UNIT (for DENSO Made)>DISASSEMBLY
Reconnect the No. 1 air conditioning radiator damper servo sub-assembly connector.
Reconnect the No. 1 blower damper servo sub-assembly connector.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
Operates between 220 to 256 pulses |
| Tester Display |
|---|
| Air Inlet Damper Targ Pulse |
No. 1 blower damper servo sub-assembly pulse operates smoothly.
| Result | Proceed to |
|---|---|
| No. 1 blower damper servo sub-assembly pulse are malfunctioning | A |
| No. 1 blower damper servo sub-assembly pulse is normal | B |
A
B
Disconnect the No. 1 blower damper servo sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (GND) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING UNIT (for DENSO Made)>DISASSEMBLY
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4 (M+) - Body ground | ·
Ignition switch ON ·
No. 1 blower damper servo sub-assembly operating (fresh) |
11 to 14 V ←→ Below 1 V |
| 5 (M-) - Body ground | ·
Ignition switch ON ·
No. 1 blower damper servo sub-assembly operating (recirculation) |
11 to 14 V ←→ Below 1 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING UNIT (for DENSO Made)>DISASSEMBLY
| *a | Component with harness connected
(No. 1 Blower Damper Servo Sub-assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 2 (sigA) - Body ground | Ignition switch ON | 4.75 V to 5.25 V |
| 3 (sigB) - Body ground | Ignition switch ON | 4.75 V to 5.25 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING UNIT (for DENSO Made)>DISASSEMBLY
Turn the ignition switch ON.
| *a | Component with harness connected
(No. 1 blower damper servo sub-assembly) |
| *b | Fresh wave form |
| *c | Recirculation wave form |
Connect an oscilloscope to terminals 2 (sig A) and 3 (sig B) of the air conditioning amplifier assembly and check the waveform.
Waveform is similar to that shown in the illustration.
| Item | Content |
|---|---|
| Tool Setting | 2.5 V/DIV., 200 ms./DIV. |
| Vehicle Condition | ·
Ignition switch ON ·
No. 1 blower damper servo sub-assembly operating |
| Proceed to |
|---|
| OK |
| NG |
OK
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING UNIT (for DENSO Made)>DISASSEMBLY
NG