Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Manual Air Conditioning System)
RM32H0E _58 Vehicle Interior _059841 HEATING / AIR CONDITIONING _0298709 AIR CONDITIONING SYSTEM(for Manual Air Conditioning System) C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)  B1423  Pressure Sensor Circuit  


DESCRIPTION

This DTC is stored if refrigerant pressure on the high pressure side is extremely low (176 kPa (1.8 kgf/cm2, 26 psi) or less)*1, (195 kPa (2.0 kgf/cm2, 28 psi) or less)*2 or extremely high (3025 kPa (30.8 kgf/cm2, 439 psi) or more)*1, (2812 kPa (28.7 kgf/cm2, 408 psi) or more)*2. The air conditioner pressure sensor, which is installed to the high pressure side pipe to detect refrigerant pressure, sends a refrigerant pressure signal to the air conditioning amplifier assembly. The air conditioning amplifier assembly converts this signal to a pressure value according to the sensor characteristics and uses it to control the compressor.

*1: for HFC-134a (R134a)

*2: for HFC-1234yf (R1234yf)


DTC No. Detection Item DTC Detection Condition Trouble Area Memory
B1423 Pressure Sensor Circuit Any of the following conditions is met:
·

Open in air conditioner pressure sensor circuit (Only when the outside temperature is 5 °C (41°F) or more)

·

Short in air conditioner pressure sensor circuit (Only when the outside temperature is 5 °C (41°F) or more)

·

for HFC-134a (R134a): Refrigerant pressure on high pressure side is extremely low (176 kPa (1.8 kgf/cm2, 26 psi) or less) or extremely high (3025 kPa (30.8 kgf/cm2, 439 psi) or more) (Only when the outside temperature is 5 °C (41°F) or more)

·

for HFC-1234yf (R1234yf): Refrigerant pressure on high pressure side is extremely low (195 kPa (2.0 kgf/cm2, 28 psi) or less) or extremely high (2812 kPa (28.7 kgf/cm2, 408 psi) or more) (Only when the outside temperature is 5 °C (41°F) or more)


·

Air conditioner pressure sensor

·

Harness or connector between air conditioner pressure sensor and air conditioning amplifier assembly

·

Air conditioning amplifier assembly

·

Cooler expansion valve (blocked, stuck)

·

Cooler condenser assembly (blocked, deterioration of cooling capacity due to dirt)

·

Cooler dryer (moisture in the refrigerant cycle cannot be absorbed)

·

Cooling fan system (cooler condenser assembly cannot be cooled down)

·

Air conditioning system (leaks, blocked)


-

DTC Detection Conditions
Vehicle Condition
Pattern 1 Pattern 2 Pattern 3 Pattern 4
Diagnosis Condition Ignition switch ON ○ ○ ○ ○
Only when the outside temperature is 5 °C (41°F) or more. ○ ○ ○ ○
Malfunction Status Open in air conditioner pressure sensor circuit ○ - - -
Short in air conditioner pressure sensor circuit - ○ - -
for HFC-134a (R134a): Refrigerant pressure on high pressure side is extremely low (176 kPa (1.8 kgf/cm2, 26 psi) - - ○ -
for HFC-1234yf (R1234yf): Refrigerant pressure on high pressure side is extremely low (195 kPa (2.0 kgf/cm2, 28 psi) or less) - - ○ -
for HFC-134a (R134a): Refrigerant pressure on high pressure side is extremely high (3025 kPa (30.8 kgf/cm2, 439 psi) or more) - - - ○
for HFC-1234yf (R1234yf): Refrigerant pressure on high pressure side is extremely high (2812 kPa (28.7 kgf/cm2, 408 psi) or more) - - - ○
Detection Time 4 seconds or more 4 seconds or more 4 seconds or more 4 seconds or more
Number of Trips 1 trip 1 trip 1 trip 1 trip

HINT:

DTC will be output when conditions for either of the patterns in the table above are met.


WIRING DIAGRAM

E357699E01
0.313,1.979 0.771,2.177 0.458,0.198 10 false A52 0.313,2.146 2.646,2.344 2.333,0.198 10 false Air Conditioner Pressure Sensor 1.938,0.396 2.167,0.594 0.229,0.198 10 false + 1.833,0.875 2.094,1.063 0.26,0.188 10 false PR 1.948,1.354 2.177,1.552 0.229,0.198 10 false - 2.146,0.406 2.375,0.604 0.229,0.198 10 false 1 2.167,0.875 2.396,1.073 0.229,0.198 10 false 2 2.167,1.354 2.396,1.552 0.229,0.198 10 false 3 4.75,0.385 4.979,0.583 0.229,0.198 10 false 34 5.031,0.396 5.396,0.594 0.365,0.198 10 false S5-3 4.74,0.875 4.969,1.073 0.229,0.198 10 false 33 4.74,1.344 4.969,1.542 0.229,0.198 10 false 32 5.021,0.875 5.385,1.073 0.365,0.198 10 false PRE 5.021,1.344 5.385,1.542 0.365,0.198 10 false SG-2 5.865,0.292 6.229,0.49 0.365,0.198 10 false 5 V 6.448,0.938 6.813,1.135 0.365,0.198 10 false AD 4.844,1.979 5.302,2.177 0.458,0.198 10 false F72 4.844,2.146 7.094,2.344 2.25,0.198 10 false Air Conditioning Amplifier Assembly

PROCEDURE

1.CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
a.

Disconnect the A52 air conditioner pressure sensor connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
A52-1 (+) - A52-3 (-) Ignition switch ON 4.75 to 5.25 V



Result:
Proceed to
OK
NG



OK

2.INSPECT AIR CONDITIONING PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)

NG

16.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONER PRESSURE SENSOR)
2.INSPECT AIR CONDITIONING PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)
a.

Reconnect the A52 air conditioner pressure sensor connector.


b.

Remove the air conditioning amplifier assembly with the connectors still connected.


c.

Measure the voltage according to the value(s) in the table below.

E357682C01
1.917,0.25 2.417,0.417 0.5,0.167 1.417,2.333 1.865,1.354 true 2.042,0.25 2.5,0.448 0.458,0.198 10 false F72 1.219,2.385 1.677,2.583 0.458,0.198 10 false PRE 0.156,0.094 0.469,0.292 0.313,0.198 10 false *a
*a Component with harness connected
(Air Conditioning Amplifier Assembly)
- -


Standard Voltage:
Tester Connection Switch Condition Specified Condition
F72-33 (PRE) - Body ground Ignition switch ON
(A/C switch: off)
0.74 to 4.61 V


HINT:

If the result is not as specified, there may be a malfunction in the air conditioning amplifier assembly, air conditioner pressure sensor, or wire harness. It is also possible that the amount of refrigerant may not be appropriate.



Result:
Proceed to
OK
NG



OK

3.INSPECT AIR CONDITIONING PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)

NG

10.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONER PRESSURE SENSOR)
3.INSPECT AIR CONDITIONING PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)
a.

Measure the voltage when the following conditions are met.

Measurement Condition:
Item Condition
Vehicle doors Fully open
Temperature setting MAX COLD
Blower speed HI
A/C switch On
Recirculation/fresh switch RECIRCULATION
Interior temperature 25 to 35°C (77 to 95°F)
Engine speed 2000 rpm

NOTICE:
·

If refrigerant pressure on the high pressure side becomes extremely high during the inspection (if the voltage exceeds 4.61 V), the fail-safe function stops compressor operation. Therefore, measure the voltage before the fail-safe operation.

·

It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the malfunction may recur after a while.



HINT:

When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the cooler (ambient temp. sensor) thermistor and the No. 1 cooler thermistor (evaporator temperature sensor) to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.


i.

Measure the voltage according to the value(s) in the table below.

E357682C03
1.917,0.25 2.417,0.417 0.5,0.167 1.417,2.333 1.865,1.354 true 2.042,0.25 2.5,0.448 0.458,0.198 10 false F72 1.219,2.385 1.677,2.583 0.458,0.198 10 false PRE 0.156,0.094 0.469,0.292 0.313,0.198 10 false *a
*a Component with harness connected
(Air Conditioning Amplifier Assembly)
- -


Standard Voltage:
Tester Connection Switch Condition Specified Condition
F72-33 (PRE) - Body ground Ignition switch ON
(A/C switch: On)
0.74 to 4.61 V


Result:
Result Proceed to
OK (When troubleshooting according to DTC) A
OK (When troubleshooting according to Problem Symptoms Table) B
NG C





A

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

B

C

4.INSPECT COOLING FAN SYSTEM
4.INSPECT COOLING FAN SYSTEM
a.

Check if the cooling fan operates normally.

Click hereEngine / Hybrid System>8NR-FTS (COOLING)>COOLING FAN SYSTEM>ON-VEHICLE INSPECTION


Result:
Proceed to
OK
NG



OK

5.CHARGE SYSTEM WITH REFRIGERANT

NG

5.CHARGE SYSTEM WITH REFRIGERANT
a.

Use a refrigerant recovery unit to recover refrigerant.


b.

Evacuate the air conditioning system.


c.

Add an appropriate amount of refrigerant.

for HFC-134a (R134a): Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT(for HFC-134a(R134a))>REPLACEMENT

for HFO-1234yf (R1234yf): Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT(for HFO-1234yf(R1234yf))>REPLACEMENT

HINT:

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the cooler expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for the DTC.



Result:
Proceed to
NEXT



NEXT

6.RECHECK FOR DTC
6.RECHECK FOR DTC
a.

Recheck for the DTC when the following conditions are met.

Measurement Condition:
Item Condition
Vehicle doors Fully open
Temperature setting MAX COLD
Blower speed HI
A/C switch On
Recirculation/fresh switch RECIRCULATION
Interior temperature 25 to 35°C (77 to 95°F)
Engine speed 2000 rpm

Body Electrical > Air Conditioner > Trouble Codes
50001 121
NOTICE:

If refrigerant pressure on the high pressure side becomes high, the DTC will be stored. It is necessary to operate the air conditioning system for a certain amount of time (approximately 10 minutes) because the DTC may be stored after the air conditioning operates for a while.


HINT:
·

When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the cooler (ambient temp. sensor) thermistor and the No. 1 cooler thermistor (evaporator temperature sensor) to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.

·

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the cooler expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for the DTC. If the DTC is not output after this work, it indicates that the cooler dryer in the cooler condenser assembly is not able to absorb moisture in the refrigerant cycle. It is necessary to replace the cooler dryer in order to complete the repair.




Result:
Result Proceed to
DTC B1423 is output A
DTC B1423 is not output B



A

7.REPLACE COOLER EXPANSION VALVE

B

REPLACE COOLER CONDENSER ASSEMBLY

7.REPLACE COOLER EXPANSION VALVE
a.

Replace the cooler expansion valve with a new one.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING UNIT (for VALEO Made)>DISASSEMBLY

HINT:

Replace the cooler expansion valve with a new one because the cooler expansion valve is either stuck or clogged.



Result:
Proceed to
NEXT



NEXT

8.CHARGE SYSTEM WITH REFRIGERANT
8.CHARGE SYSTEM WITH REFRIGERANT
a.

Use a refrigerant recovery unit to recover refrigerant.


b.

Evacuate the air conditioning system.


c.

Add an appropriate amount of refrigerant.

for HFC-134a (R134a): Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT(for HFC-134a(R134a))>REPLACEMENT

for HFO-1234yf (R1234yf): Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT(for HFO-1234yf(R1234yf))>REPLACEMENT

HINT:

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the cooler expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for the DTC.



Result:
Proceed to
NEXT



NEXT

9.RECHECK FOR DTC
9.RECHECK FOR DTC
a.

Recheck for the DTC when the following conditions are met.

Measurement Condition:
Item Condition
Vehicle doors Fully open
Temperature setting MAX COLD
Blower speed HI
A/C switch On
Recirculation/fresh switch RECIRCULATION
Interior temperature 25 to 35°C (77 to 95°F)
Engine speed 2000 rpm

Body Electrical > Air Conditioner > Trouble Codes
50001 121
NOTICE:

If refrigerant pressure on the high pressure side becomes high, the DTC will be stored. It is necessary to operate the air conditioning system for a certain amount of time (approximately 10 minutes) because the DTC may be stored after the air conditioning operates for a while.


HINT:
·

When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the cooler (ambient temp. sensor) thermistor and the No. 1 cooler thermistor (evaporator temperature sensor) to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.

·

If refrigerant pressure is not normal after replacing the cooler expansion valve with a new or known good one, the cooler condenser assembly or pipes may be clogged due to dirt, dust or other foreign matter. In this case, clean or replace the cooler condenser assembly or pipes.




Result:
Result Proceed to
DTC B1423 is not output A
DTC B1423 is output B



A

END

B

CLEAN OR REPLACE COOLER CONDENSER ASSEMBLY

10.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONER PRESSURE SENSOR)
a.

Disconnect the A52 air conditioner pressure sensor connector.


b.

Disconnect the F72 air conditioning amplifier assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A52-2 (PR) - F72-33 (PRE) Always Below 1 Ω
A52-2 (PR) or F72-33 (PRE) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

11.INSPECT FOR AIR CONDITIONING SYSTEM LEAK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

11.INSPECT FOR AIR CONDITIONING SYSTEM LEAK
a.

Install a manifold gauge set.


b.

Recover the refrigerant from the air conditioning system using a refrigerant recovery unit.


c.

Evacuate the air conditioning system and check that vacuum can be maintained.

OK:

Vacuum can be maintained in the air conditioning system.


HINT:

If vacuum cannot be maintained in the air conditioning system, refrigerant may be leaking from it. In this case, it is necessary to repair or replace the leaking part of the air conditioning system.



Result:
Proceed to
OK
NG



OK

12.CHARGE SYSTEM WITH REFRIGERANT

NG

15.REPAIR AIR CONDITIONING SYSTEM LEAK
12.CHARGE SYSTEM WITH REFRIGERANT
a.

Use a refrigerant recovery unit to recover refrigerant.


b.

Evacuate the air conditioning system.


c.

Add an appropriate amount of refrigerant.

for HFC-134a (R134a): Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT(for HFC-134a(R134a))>REPLACEMENT

for HFO-1234yf (R1234yf): Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT(for HFO-1234yf(R1234yf))>REPLACEMENT

HINT:

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the cooler expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for the DTC.



Result:
Proceed to
NEXT



NEXT

13.RECHECK FOR DTC
13.RECHECK FOR DTC
a.

Recheck for the DTC when the following conditions are met.

Measurement Condition:
Item Condition
Vehicle doors Fully open
Temperature setting MAX COLD
Blower speed HI
A/C switch On
Recirculation/fresh switch RECIRCULATION
Interior temperature 25 to 35°C (77 to 95°F)
Engine speed 2000 rpm

Body Electrical > Air Conditioner > Trouble Codes
50001 121
NOTICE:

If refrigerant pressure on the high pressure side becomes high, the DTC will be stored. It is necessary to operate the air conditioning system for a certain amount of time (approximately 10 minutes) because the DTC may be stored after the air conditioning operates for a while.


HINT:

When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the cooler (ambient temp. sensor) thermistor and the No. 1 cooler thermistor (evaporator temperature sensor) to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.



Result:
Result Proceed to
DTC B1423 is output A
DTC B1423 is not output B


NOTICE:

If the DTC was stored to an insufficient or excessive amount of refrigerant, the problem may have been solved after performing the previous step. However, the root cause of insufficient refrigerant may be refrigerant leaks. The root cause of excessive refrigerant may be adding too much refrigerant when the level was insufficient. Therefore, identify and repair the area where refrigerant leaks from as necessary.



A

14.INSPECT AIR CONDITIONING PRESSURE SENSOR

B

END

14.INSPECT AIR CONDITIONING PRESSURE SENSOR
a.

Install a manifold gauge set.


b.

Reconnect the A52 air conditioner pressure sensor connector.


c.

Remove the air conditioning amplifier assembly.


d.

Reconnect the F72 air conditioning amplifier assembly connector.


e.

Turn the ignition switch ON.


f.

Measure the voltage according to the value(s) in the table below.

E357682C04
1.917,0.25 2.417,0.417 0.5,0.167 1.417,2.333 1.865,1.354 true 2.802,2.375 2,1.333 true 2.042,0.25 2.5,0.448 0.458,0.198 10 false F72 1.219,2.385 1.677,2.583 0.458,0.198 10 false PRE 0.156,0.094 0.469,0.292 0.313,0.198 10 false *a 2.688,2.417 3.646,2.688 0.958,0.271 10 false SG-2
*a Component with harness connected
(Air Conditioning Amplifier Assembly)
- -


Standard Voltage (for HFC-134a (R134a)):
Tester Connection Condition Specified Condition
F72-33 (PRE) - F72-32 (SG-2) Refrigerant pressure: Normal pressure (less than 3025 kPa (30.8 kgf/cm2, 439 psi) and more than 176 kPa (1.8 kgf/cm2, 26 psi)) 0.74 to 4.61 V


Standard Voltage (for HFC-1234yf (R1234yf)):
Tester Connection Condition Specified Condition
F72-33 (PRE) -F72-32 (SG-2) Refrigerant pressure: Normal pressure (less than 2812 kPa (28.7 kgf/cm2, 408 psi) and more than 195 kPa (2.0 kgf/cm2, 28 psi)) 0.74 to 4.61 V



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

15.REPAIR AIR CONDITIONING SYSTEM LEAK
a.

b.

Repair the identified area of the air conditioning system.


c.

Evacuate the air conditioning system.


Result:
Result Proceed to
for HFC-134a (R134a) A
for HFO-1234yf (R1234yf) B



A

B

16.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONER PRESSURE SENSOR)
a.

Disconnect the F72 air conditioning amplifier assembly connector.


b.

Disconnect the A52 air conditioner pressure sensor connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A52-1 (+) - F72-34 (S5-3) Always Below 1 Ω
A52-3 (-) - F72-32 (SG-2) Always Below 1 Ω
A52-1 (+) or F72-34 (S5-3) - Body ground Always 10 kΩ or higher
A52-3 (-) or F72-32 (SG-2) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR