Home › Power Source / Network › POWER DISTRIBUTION › INTEGRATION RELAY › from 2020.08
RM32H0E _57 Power Source / Network _060596 POWER DISTRIBUTION _0297232 INTEGRATION RELAY A

POWER DISTRIBUTION  INTEGRATION RELAY  INSTALLATION  


PROCEDURE

Hide 82641 1.INSTALL NO. 1 INTEGRATION RELAY

a.

Connect the 2 connectors.


b.
E353737C01
0,0 0,0 false
V113147

Install in this Direction


Engage the claws to install the No. 1 integration relay as shown in the illustration.


Hide 82662A 2.INSTALL NO. 1 RELAY BLOCK COVER

a.
E353735C01
0,0 0,0 false
V113147

Install in this Direction


Engage the claws to install the No. 1 relay block cover as shown in the illustration.


Hide 3.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

Hide 4. INITIALIZATION AFTER RECONNECTING BATTERY TERMINAL

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART