Home › Power Source / Network › 3ZR-FAE (BATTERY / CHARGING) › GENERATOR › from 2020.08
RM32H0E _57 Power Source / Network _060210 3ZR-FAE BATTERY / CHARGING _0295253 GENERATOR A

3ZR-FAE BATTERY / CHARGING  GENERATOR  INSTALLATION  


PROCEDURE

Hide 27020 1.INSTALL GENERATOR ASSEMBLY

a.

Install the wire harness clamp bracket to the generator assembly with the bolt.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


b.
A392506N01
0.781,0.281 0.938,0.479 0.156,0.198 10 true A 0.927,1.927 1.083,2.125 0.156,0.198 10 true B

Install the generator assembly with the 2 bolts.

Torque:
Bolt A : 25 N*m (255 kgf*cm, 18 ft.*lbf)
Bolt B : 43 N*m (438 kgf*cm, 32 ft.*lbf)


c.

Engage the clamp to connect the engine wire to the wire harness clamp bracket.


d.

Connect the generator assembly connector.


e.

Connect the engine wire to terminal B with the nut.

Torque:
9.8 N*m (100 kgf*cm, 87 in.*lbf)


f.

Install the terminal cap to the generator assembly.


Hide 2.INSTALL FAN AND GENERATOR V BELT

Hide 3.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

Hide 4. INITIALIZATION AFTER RECONNECTING BATTERY TERMINAL

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART