The skid control ECU is connected to the combination meter assembly via CAN communication.
If any of the following is detected, the brake warning light remains on:
The skid control ECU connector is disconnected from the skid control ECU.
The brake fluid level is insufficient.
The parking brake is applied.
EBD operation is not possible.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Check if a CAN communication system DTC is output.
Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>DIAGNOSIS SYSTEM
| Result | Proceed to |
|---|---|
| DTC is not output. | A |
| DTC is output. | B |
A
B
Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING
Check if the skid control ECU connector is securely connected.
The connector is securely connected.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check the battery voltage.
11 to 14 V
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Skid Control ECU (Brake Actuator Assembly)) |
Disconnect the A49 skid control ECU connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A49-25 (+BS) - Body ground | Always | 11 to 14 V |
| A49-25 (+BS) - A49-38 (GND1) | Always | 11 to 14 V |
| A49-28 (IG1) - Body ground | Ignition switch ON | 11 to 14 V |
| A49-28 (IG1) - A49-38 (GND1) | Ignition switch ON | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Skid Control ECU (Brake Actuator Assembly)) |
Turn the ignition switch off.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A49-38 (GND1) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Reconnect the A49 skid control ECU connector.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Select the Data List using the intelligent tester.
Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>ANTI-LOCK BRAKE SYSTEM>DATA LIST / ACTIVE TEST
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Parking Brake SW | Parking brake switch | ON or OFF | ON: Parking brake applied
OFF: Parking brake released |
- |
| Tester Display |
|---|
| Parking Brake SW |
Using the intelligent tester, check the switch operation signal received when the parking brake is operated.
When the parking brake is operated, the display changes as shown above.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component without harness connected
(Brake Fluid Level Warning Switch (Brake Master Cylinder Reservoir Sub-assembly)) |
Turn the ignition switch off.
Remove the reservoir filler cap and the strainer.
Disconnect the A30 brake fluid level warning switch connector.
Measure the resistance according to the value(s) in the table below.
A float is located inside the reservoir. Its position changes according to the brake fluid level.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 1 (+) - 2 (E) | Switch OFF (Float up) | 1.9 to 2.1 kΩ |
| 1 (+) - 2 (E) | Switch ON (Float down) | Below 1 Ω |
If there is no problem after finishing the above check, adjust the brake fluid level to the MAX level.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the I18 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I18-19 (SW) - A30-1 (+) | Always | Below 1 Ω |
| I18-19 (SW) - Body ground | Always | 10 kΩ or higher |
| A30-2 (E) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Reconnect the I18 combination meter assembly connector and the A30 brake fluid level warning switch connector.
Perform an Active Test of the combination meter assembly (meter CPU) using the intelligent tester.
Click hereVehicle Interior>METER / GAUGE / DISPLAY>METER / GAUGE SYSTEM>DATA LIST / ACTIVE TEST
| Tester Display |
|---|
| Indicat. Lamp Brake |
Check the combination meter assembly.
The brake warning light turns on or off in accordance with the Active Test operation.
If troubleshooting has been carried out according to Problem Symptoms Table, refer back to the table and proceed to the next step before replacing parts.
Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>ANTI-LOCK BRAKE SYSTEM>PROBLEM SYMPTOMS TABLE
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component without harness connected
(Parking Brake Switch Assembly) |
Turn the ignition switch off.
Disconnect the A42 or I169 parking brake switch assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 1 (+) - Body ground | Parking brake switch ON
(Switch pin free) |
Below 1 Ω |
| 1 (+) - Body ground | Parking brake switch OFF
(Switch pin pushed in) |
10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
for Automatic Transaxle: Click hereBrake>PARKING BRAKE>PARKING BRAKE SWITCH(for Automatic Transaxle LHD)>REMOVAL
for Manual Transaxle: Click hereBrake>PARKING BRAKE>PARKING BRAKE SWITCH(for Manual Transaxle)>REMOVAL
Disconnect the 3D or 3A main body ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3D-20 (PKB) - A42-1 (+) | Always | Below 1 Ω |
| 3D-20 (PKB) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3A-36 (PKB) - I169-1 (+) | Always | Below 1 Ω |
| 3A-36 (PKB) - Body ground | Always | 10 kΩ or higher |
If troubleshooting has been carried out according to Problem Symptoms Table, refer back to the table and proceed to the next step before replacing parts.
Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>ANTI-LOCK BRAKE SYSTEM>PROBLEM SYMPTOMS TABLE
| Proceed to |
|---|
| OK |
| NG |
OK
NG