DTC P0037 Oxygen Sensor Heater Control Circuit Low (Bank 1 Sensor 2) |
DTC P0038 Oxygen Sensor Heater Control Circuit High (Bank 1 Sensor 2) |
DTC P0141 Oxygen Sensor Heater Circuit Malfunction (Bank 1 Sensor 2) |
DTC P102D O2 Sensor Heater Circuit Performance Bank 1 Sensor 2 Stuck ON |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0037 | Heated oxygen sensor heater current is the specified value or less while the heater is operating (1 trip detection logic). |
|
| P0038 | Heated oxygen sensor heater current reaches high limit (Hybrid IC high current limiter monitor input "Fail") (1 trip detection logic). |
|
| P0141 | The cumulative heater resistance correction value exceeds the threshold (2 trip detection logic). |
|
| P102D | Heated oxygen sensor heater current is higher than the specified value while the heater is not operating (1 trip detection logic). | ECM |
| Related DTCs | P0037: Heated oxygen sensor heater (sensor 2) range check (low current) P0038: Heated oxygen sensor heater (sensor 2) range check (high current) P0141: Heated oxygen sensor heater performance (sensor 2) P102D: Heated oxygen sensor heater performance (sensor 2) |
| Required Sensors/Components (Main) | Heated oxygen sensor heater (sensor 2) |
| Required Sensors/Components (Related) | - |
| Frequency of Operation | Continuous: P0037, P0038, P102D Once per driving cycle: P0141 |
| Duration | 0.5 seconds: P0037 Within 3 seconds: P0038 10 seconds: P0141 0.5 seconds: P102D |
| MIL Operation | Immediate: P0037, P0038, P102D 2 driving cycles: P0141 |
| Sequence of Operation | None |
| Monitor runs whenever the following DTCs are not stored | None |
| All of the following conditions are met | - |
| Battery voltage | 10.5 V or higher |
| Engine | Running |
| Starter | Off |
| Catalyst active A/F control | Not operating |
| Time after heater on | 10 seconds or more |
| Learned heater off current operation | Completed |
| Learned heater off current operation | Succeeded |
| Oxygen sensor heater high current fail (P0038) | Not detected |
| Heater on current - Learned heater off current | 0.15 A or less |
| Heater output | On |
| All of the following conditions are met | - |
| Battery voltage | 10.5 V or higher |
| Engine | Running |
| Starter | Off |
| Catalyst active A/F control | Not operating |
| Time after heater on | 10 seconds or more |
| Learned heater off current operation | Completed |
| Oxygen sensor heater high current fail (P0038) | Not detected |
| Heater off current | Higher than 3.5 A |
| Hybrid IC high current limiter monitor input | Fail |
| All of the following conditions are met | - |
| Battery voltage | 10.5 V or higher |
| Engine | Running |
| Starter | Off |
| Catalyst active A/F control | Not operating |
| Time after heater on | 10 seconds or more |
| Learned heater off current operation | Completed |
| Hybrid IC high current limiter monitor input | Fail |
| Heater output | On |
| All of the following conditions are met | - |
| Heated oxygen sensor heater circuit fail (P0037, P0038 and P102D) | Not detected |
| Battery voltage | 10.5 V or higher |
| Fuel cut | Off |
| Time after fuel cut on to off | 30 seconds or more |
| Accumulated heater on time | 100 seconds or more |
| Learned heater off current operation | Completed |
| Duration that heated oxygen sensor impedance is less than 15 kΩ | 2 seconds or more |
| All of the following conditions are met | - |
| Battery voltage | 10.5 V or higher |
| Engine | Running |
| Starter | Off |
| Catalyst active A/F control | Not operating |
| Time after heater on | 10 seconds or more |
| Learned heater off current operation | Completed |
| Oxygen sensor heater low current fail (P0037) | Not detected |
| Oxygen sensor heater high current fail (P0038) | Not detected |
| Heater output | Off |
| Heater off current | Higher than 3.5 A |
| Hybrid IC high current limiter monitor input | Fail |
| Heater on current - Learned heater off current | 0.15 A or less |
| Heater on current | 1 A or less |
| Both of the following conditions are met | - |
| Hybrid IC high current limiter monitor input | Fail |
| Heater output | On |
| Heater resistance | Varies with sensor element temperature (Example: Higher than 23 Ω) |
| Heater on current | Higher than 1 A |
| Monitor ID | Test ID | Scaling | Unit | Description |
| $42 | $91 | Multiply by 0.001 | Ohm | Oxygen sensor heater resistance bank 1 sensor 2 |

| Techstream Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|

| 1.INSPECT HEATED OXYGEN SENSOR (HEATER RESISTANCE) |
Inspect the heated oxygen sensor (Click here).
|
| ||||
| OK | |
| 2.CHECK TERMINAL VOLTAGE (POWER SOURCE OF HEATED OXYGEN SENSOR) |
![]() |
Disconnect the heated oxygen sensor connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E21-2 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| *a | Front view of wire harness connector (to Heated Oxygen Sensor) |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - ECM) |
Disconnect the heated oxygen sensor connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E21-1 (HT1B) - E26-24 (HT1B) | Always | Below 1 Ω |
| E21-1 (HT1B) or E26-24 (HT1B) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 4.CHECK WHETHER DTC OUTPUT RECURS (DTC P0037, P0038, P0141 OR P102D) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Clear the DTCs (Click here).
Turn the ignition switch off and wait for at least 30 seconds.
Turn the ignition switch to ON.
Turn the Techstream on.
Drive the vehicle in accordance with the driving pattern described in Confirmation Driving Pattern.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Read the pending DTCs.
| Result | Proceed to |
| DTC is not output | A |
| DTC P0037, P0038, P0141 or P102D is output | B |
|
| ||||
| A | ||
| ||
| 5.CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - NO. 1 INTEGRATION RELAY) |
Disconnect the heated oxygen sensor connector.
Remove the No. 1 integration relay from the engine room relay block and junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E21-2 (+B) - 1A-6 | Always | Below 1 Ω |
| E21-2 (+B) or 1A-6 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 6.CHECK TERMINAL VOLTAGE (POWER SOURCE OF NO. 1 INTEGRATION RELAY) |
![]() |
Remove the No. 1 integration relay from the engine room relay block and junction block assembly.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1D-1 - Body ground | Always | 11 to 14 V |
| *a | Front view of wire harness connector (to No. 1 Integration Relay) |
|
| ||||
| OK | ||
| ||