The air cleaner is equipped with 2 inlets, one of which is opened or closed by the air intake control valve. This system reduces intake noise and increases engine power at low-to-high engine speed ranges.
When the engine is operating in the low-to-mid speed range, this control operates the air intake control valve to close one of the air cleaner inlets. When the engine speed is higher than 3600 rpm and the opening angle of the throttle valve is more than 60°, the ECM activates the vacuum switching valve (for air intake control valve) and opens the air intake control valve.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory |
|---|---|---|---|---|---|
| P1660 | VSV for AICVS Circuit | The following conditions are met simultaneously for 0.5 seconds or more (2 trip detection logic):
1.
Voltage of terminal air intake control valve of the ECM is low when the VSV is off 2.
The engine has been started |
·
Open or short in air intake control valve circuit ·
Air intake control valve ·
ECM |
Comes on | DTC stored |
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Read freeze frame data using the intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.
| *1 | Air |
| *2 | Port E |
| *3 | Port F |
| *4 | Air Filter |
| *a | Vacuum Switching Valve is On |
| *b | Vacuum Switching Valve is Off |
Disconnect the vacuum hose (Port F) from the vacuum switching valve (for air intake control valve).
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Enter the following menus: Powertrain / Engine / Active Test / Activate the VSV for AICS.
| Tester Display |
|---|
| Activate the VSV for AICS |
Check the operation of the vacuum switching valve (for air intake control valve) when the vacuum switching valve (for air intake control valve) is operated using the tester.
| Tester Operation | Specified Condition |
|---|---|
| ON | Air from port E flows out through port F |
| OFF | Air from port E flows out through the air filter |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the vacuum switching valve (for air intake control valve).
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Vacuum Switching Valve (for Air Intake Control Valve)) |
Disconnect the vacuum switching valve (for air intake control valve) connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A9-1 - Body ground | ignition switch ON | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the vacuum switching valve (for air intake control valve) connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A9-2 - E26-46 (AICV) | Always | Below 1 Ω |
| A9-2 or E26-46 (AICV) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the No. 1 integration relay from the engine room relay block and junction block assembly.
Disconnect the vacuum switching valve (for air intake control valve) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1C-3 - A9-1 | Always | Below 1 Ω |
| 1C-3 or A9-1 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG