The ECM constantly generates 5 V power source voltage from the battery voltages supplied to the +B (BATT) terminal to operate the microprocessor. The ECM also provides this power to the sensors through the VC output circuit.
When the VC circuit is short-circuited, the microprocessor in the ECM and sensors that are supplied with power through the VC circuit are deactivated because the power is not supplied from the VC circuit. Under this condition, the system does not start up and the MIL does not illuminate even if the system malfunctions.
Under normal conditions, the MIL is illuminated when the ignition switch is turned to ON. The MIL goes off when the engine is started.
Check that the Malfunction Indicator Lamp (MIL) lights up when the ignition switch is turned to ON.
MIL lights up.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Check the communication between the tester and ECM.
| Result | Proceed to |
|---|---|
| Communication is not possible | A |
| Communication is possible | B |
A
B
Disconnect the throttle with motor body assembly connector.
Turn the ignition switch to ON.
Check the MIL.
| Result | Proceed to |
|---|---|
| MIL does not illuminate | A |
| MIL illuminates | B |
Perform "Inspection After Repair" after replacing the throttle with motor body assembly.
Click hereEngine / Hybrid System>2GR-FE ENGINE CONTROL>SFI SYSTEM>INITIALIZATION
A
B
Disconnect the accelerator pedal sensor assembly connector.
Turn the ignition switch to ON.
Check the MIL.
| Result | Proceed to |
|---|---|
| MIL does not illuminate | A |
| MIL illuminates | B |
A
B
Disconnect the VVT sensor (for intake camshaft of bank 1) connector.
Turn the ignition switch to ON.
Check the MIL.
| Result | Proceed to |
|---|---|
| MIL does not illuminate | A |
| MIL illuminates | B |
A
B
Disconnect the VVT sensor (for intake camshaft of bank 2) connector.
Turn the ignition switch to ON.
Check the MIL.
| Result | Proceed to |
|---|---|
| MIL does not illuminate | A |
| MIL illuminates | B |
A
B
Disconnect the VVT sensor (for exhaust camshaft of bank 1) connector.
Turn the ignition switch to ON.
Check the MIL.
| Result | Proceed to |
|---|---|
| MIL does not illuminate | A |
| MIL illuminates | B |
A
B
Disconnect the VVT sensor (for exhaust camshaft of bank 2) connector.
Turn the ignition switch to ON.
Check the MIL.
| Result | Proceed to |
|---|---|
| MIL does not illuminate | A |
| MIL illuminates | B |
A
B
Disconnect the throttle with motor body assembly connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E16-5 (VC) or E26-126 (VCTA) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the accelerator pedal sensor assembly connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A36-4 (VCPA) or A25-56 (VCPA) - Body ground | Always | 10 kΩ or higher |
| A36-1 (VCP2) or A25-59 (VCP2) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the VVT sensor (for intake camshaft of bank 1) connector.
Disconnect the VVT sensor (for intake camshaft of bank 2) connector.
Disconnect the VVT sensor (for exhaust camshaft of bank 1) connector.
Disconnect the VVT sensor (for exhaust camshaft of bank 2) connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E26-111 (VCV1) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG