Home › Power Source / Network › NETWORKING › CAN COMMUNICATION SYSTEM › 2012.02–2014.05
RM2040EQ _57 Power Source / Network _014721 NETWORKING _0075042 CAN COMMUNICATION SYSTEM C

NETWORKING  CAN COMMUNICATION SYSTEM  U1002  Lost Communication with Gateway Module  


DESCRIPTION

·

The power management control ECU will store this DTC when no signals can be received from the ECUs that have been memorized as those that are connected to sub bus 11.

·

When the power management control ECU receives a response signal from the ECUs connected to sub bus 11, the power management control ECU recognizes and memorizes that the ECU is connected to sub bus 11. Based on this memorized data, the power management control ECU monitors for malfunctions in the ECUs connected to sub bus 11 when communicating with those ECUs. If the power management control ECU cannot receive response signals from the ECUs that have been memorized as those connected to sub bus 11, the power management control ECU determines that a malfunction exists.


DTC No. Detection Item DTC Detection Condition Trouble Area Note
U1002 Lost Communication with Gateway Module The power management control ECU cannot receive signals from all ECUs that have been memorized as those connected to sub bus 11.
·

Open or short in sub bus 11 main line or connector

·

Open or short in sub bus 11 branch line or connector

·

Power management control ECU

·

Blind spot monitor sensor LH

·

Blind spot monitor sensor RH

·

Open or short in CAN No. 2 junction connector

·

Open or short in CAN No. 3 junction connector

·

Open or short in CAN No. 4 junction connector


The power management control ECU stores DTCs when it detects a communication stop or network communication error for ECUs connected to sub bus 11.

HINT:

This diagnosis procedure is for when DTC U1002 is output by the power management control ECU (Intelligent tester display: PM1 Gateway).


WIRING DIAGRAM

C250836E03
5.302,0.521 6.51,0.708 1.208,0.188 10 false x: Suspected Area 1.26,0.51 2.552,0.917 1.292,0.406 10 false Power Management Control ECU 3.458,0.281 3.875,0.469 0.417,0.188 10 false 120 Ω 5.813,3.302 7.031,3.677 1.219,0.375 10 false Blind Spot Monitor Sensor RH 3.406,7.385 3.823,7.573 0.417,0.188 10 false 120 Ω 4.719,5.323 6.688,5.51 1.969,0.188 10 false CAN No. 3 Junction Connector 4.958,7.031 6.906,7.219 1.948,0.188 10 false CAN No. 4 Junction Connector 0.844,2.76 2.833,2.948 1.99,0.188 10 false CAN No. 2 Junction Connector 3.646,7.969 5.365,8.156 1.719,0.188 10 false : CAN Branch Line (CANH) 3.646,8.375 5.365,8.563 1.719,0.188 10 false : CAN Branch Line (CANL) 0.979,7.969 2.896,8.156 1.917,0.188 10 false : CAN Main Bus Line (CANH) 0.979,8.375 2.896,8.563 1.917,0.188 10 false : CAN Main Bus Line (CANL) 2.74,0.917 3.125,1.083 0.385,0.167 10 false CA2L 1.031,4.979 1.417,5.146 0.385,0.167 10 false CA1P 1.031,5.563 1.417,5.729 0.385,0.167 10 false CA1N 5.458,3.302 5.854,3.469 0.396,0.167 10 false O28 0.458,5.833 1.635,6.188 1.177,0.354 10 false Blind Spot Monitor Sensor LH 0.156,5.833 0.49,6 0.333,0.167 10 false T10 2.99,1.125 3.198,1.292 0.208,0.167 10 false 35 1.469,4.99 1.677,5.156 0.208,0.167 10 false 8 1.469,5.563 1.677,5.729 0.208,0.167 10 false 4 2.99,2.083 3.198,2.25 0.208,0.167 10 false 22 4,2.083 4.208,2.25 0.208,0.167 10 false 11 4.344,2.469 4.552,2.635 0.208,0.167 10 false 9 4.344,3.01 4.552,3.177 0.208,0.167 10 false 20 2.677,4.99 2.885,5.156 0.208,0.167 10 false 10 1.979,4.938 2.188,5.104 0.208,0.167 10 false R 1.979,5.594 2.188,5.76 0.208,0.167 10 false B 2.677,5.563 2.885,5.729 0.208,0.167 10 false 21 2.896,1.365 3.104,1.531 0.208,0.167 10 false LG 5.063,2.417 5.271,2.583 0.208,0.167 10 false R 5.063,3.063 5.271,3.229 0.208,0.167 10 false B 4.063,1.365 4.271,1.531 0.208,0.167 10 false G 2.99,1.844 3.104,2.01 0.115,0.167 10 false B 4.063,1.844 4.229,2.01 0.167,0.167 10 false V 4.01,1.125 4.219,1.292 0.208,0.167 10 false 34 5.583,2.469 5.792,2.635 0.208,0.167 10 false 8 5.583,3.01 5.792,3.177 0.208,0.167 10 false 4 1.073,0.51 1.219,0.677 0.146,0.167 10 false I3 4.021,0.917 4.406,1.083 0.385,0.167 10 false CA2H 5.76,2.427 6.198,2.594 0.438,0.167 10 false CA1P 5.76,3.042 6.198,3.208 0.438,0.167 10 false CA1N 4.01,6.531 4.219,6.698 0.208,0.167 10 false 3 3.052,6.531 3.26,6.698 0.208,0.167 10 false 2 3.01,6.323 3.219,6.49 0.208,0.167 10 false B 4.042,6.323 4.25,6.49 0.208,0.167 10 false L 2.99,5.979 3.198,6.146 0.208,0.167 10 false 20 4.01,5.979 4.219,6.146 0.208,0.167 10 false 9 2.99,4.531 3.198,4.698 0.208,0.167 10 false 22 4.01,4.531 4.229,4.698 0.219,0.167 10 false 11 4.01,3.531 4.219,3.698 0.208,0.167 10 false 10 2.979,3.531 3.188,3.698 0.208,0.167 10 false 21 3,4.042 3.208,4.208 0.208,0.167 10 false B 4.042,4.042 4.25,4.208 0.208,0.167 10 false G 2.729,6.729 3.167,6.896 0.438,0.167 10 false CANL 4.031,6.74 4.469,6.906 0.438,0.167 10 false CANH 0.521,2.76 0.833,2.927 0.313,0.167 10 false O30 4.406,5.323 4.708,5.49 0.302,0.167 10 false T15 4.646,7.031 4.927,7.198 0.281,0.167 10 false T16 0.135,0.063 1.385,0.406 1.25,0.344 12 false Sub Bus 11:

CAUTION / NOTICE / HINT

NOTICE:
·

Before measuring the resistance of the CAN bus, turn the power switch off and leave the vehicle for 1 minute or more without operating the key, switches or opening or closing the doors. After that, disconnect the cable from the negative (-) auxiliary battery terminal and leave the vehicle for 1 minute or more before measuring the resistance.

·

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notice before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION

·

Because the order of diagnosis is important to allow correct diagnosis, make sure to begin troubleshooting using How to Proceed with Troubleshooting when CAN communication system related DTCs are output.

Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING

·

After performing repairs, perform the DTC check procedure and confirm that the DTCs are not output again.

·

DTC check procedure: Turn the power switch on (IG), turn the blind spot monitor main switch on, wait at least 11.68 seconds and then drive the vehicle at a speed of 5 km/h (3 mph) or more for at least 11.84 seconds.

·

After the repair, perform CAN Bus Check and check that all the ECUs and sensors connected to the CAN communication system are displayed.

Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>DIAGNOSIS SYSTEM



HINT:
·

Operating the power switch, any other switches or a door triggers related ECU and sensor communication on the CAN. This communication will cause the resistance value to change.

·

Even after DTCs are cleared, if a DTC is stored again after driving the vehicle for a while, the malfunction may be occurring due to vibration of the vehicle. In such a case, wiggling the ECUs or wire harness while performing the inspection below may help determine the cause of the malfunction.



PROCEDURE

1.CHECK SUB BUS 11
a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.
A261175C13
1.813,0.583 2.313,0.875 0.5,0.292 1.604,1.083 1.698,1.083 1.698,1.083 1.823,1.688 false 2.552,1.083 2.448,1.083 2.448,1.083 2.229,1.688 false 1.531,2.917 1.625,2.917 1.625,2.917 1.813,1.906 false 2.167,2.906 2.083,2.906 2.083,2.906 1.865,1.906 false 0.063,0.021 0.271,0.24 0.208,0.219 10 false *a 2.573,1 2.99,1.156 0.417,0.156 10 false AM22 1.375,1 1.573,1.156 0.198,0.156 10 false E1 1.99,0.635 2.167,0.802 0.177,0.167 10 false I3 1.083,2.833 1.5,2.99 0.417,0.156 10 false CA2L 2.208,2.813 2.625,2.969 0.417,0.156 10 false CA2H
*a Component with harness connector
(Power Management Control ECU)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition Result
I3-34 (CA2H) - I3-35 (CA2L) Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω Below 54 Ω: Short circuit between bus lines
70 Ω or higher: Open circuit in a main bus line
I3-34 (CA2H) - I3-6 (E1) Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher Below 200 Ω: CANH ground short
I3-35 (CA2L) - I3-6 (E1) Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher Below 200 Ω: CANL ground short



c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition Result
I3-34 (CA2H) - I3-1 (AM22) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher Below 6 kΩ: CANH +B short
I3-35 (CA2L) - I3-1 (AM22) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher Below 6 kΩ: CANL +B short



Result:
Result Proceed to
OK A
Open circuit in CAN main bus line B
Short circuit between bus lines C
·

Ground short

·

+B short


D



A

2.RECONFIRM DTC OUTPUT

B

3.CHECK FOR OPEN IN SUB BUS 11 MAIN LINES (POWER MANAGEMENT CONTROL ECU)

C

7.CHECK FOR SHORT IN SUB BUS 11 LINES (POWER MANAGEMENT CONTROL ECU)

D

12.CHECK FOR SHORT IN SUB BUS 11 LINE (CAN NO. 2 J/C)
2.RECONFIRM DTC OUTPUT
a.

Reconnect the cable to the negative (-) auxiliary battery terminal.


b.

Connect the intelligent tester to the DLC3.


c.

Turn the power switch on (IG).


d.

Turn the intelligent tester on.


e.

Clear the DTCs.


f.

Turn the power switch off.


g.

Turn the power switch on (IG) and recheck for DTCs.

Body Electrical > PM1 Gateway > Trouble Codes
50001 217

Result:
Result Proceed to
U1002 is output from power management control ECU.
(Intelligent tester display: PM1 Gateway)
A
Other DTC is output. B



A

B

GO TO DIAGNOSIS PROCEDURE INDICATED BY OUTPUT DTC

3.CHECK FOR OPEN IN SUB BUS 11 MAIN LINES (POWER MANAGEMENT CONTROL ECU)
a.

Disconnect the power management control ECU connector.


b.
A204445C86
1.885,0.5 2.375,0.792 0.49,0.292 1.823,2.573 1.458,2.635 false 1.865,2.573 1.573,3.031 false 2.052,0.563 2.26,0.74 0.208,0.177 10 false I3 1.104,2.563 1.469,2.74 0.365,0.177 10 false CA2L 1.156,2.99 1.542,3.167 0.385,0.177 10 false CA2H 0.146,0.083 0.719,0.448 0.573,0.365 10 false *a
*a Rear view of wire harness connector
(to Power Management Control ECU)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
I3-34 (CA2H) - I3-35 (CA2L) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω



Result:
Result
OK
NG



OK

NG

4.CHECK FOR OPEN IN SUB BUS 11 MAIN LINES (CAN NO. 2 J/C - POWER MANAGEMENT CONTROL ECU)
4.CHECK FOR OPEN IN SUB BUS 11 MAIN LINES (CAN NO. 2 J/C - POWER MANAGEMENT CONTROL ECU)
a.

Reconnect the power management control ECU connector.


b.

Disconnect the wire harness connector from the CAN No. 2 junction connector.


c.
C238890C16
0.181,0.161 0.331,0.313 0.149,0.153 10 *a 2.569,0.431 3.118,0.584 0.549,0.153 10 CANH*b 2.677,0.689 3.226,0.841 0.549,0.153 10 CANH*c 2.534,0.514 2.209,0.514 2.209,0.514 2.209,1.356 false 2.648,0.771 2.323,0.771 2.323,0.771 2.323,1.356 false 2.648,1.886 2.323,1.886 2.323,1.886 2.323,1.572 false 1.398,1.963 1.946,2.115 0.549,0.153 10 CANL*b 2.676,1.8 3.225,1.952 0.549,0.153 10 CANL*c 2.057,2.058 2.209,2.058 2.209,2.058 2.209,1.572 false 0.552,1.283 0.836,1.484 0.283,0.201 10 O30 0.473,1.236 0.963,1.497 0.49,0.261
*a Front view of wire harness connector
(to CAN No. 2 Junction Connector)
*b to CAN No. 3 Junction Connector
*c to Power Management Control ECU


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
O30-10 (CANH) - O30-21 (CANL) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω
O30-11 (CANH) - O30-22 (CANL) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω



Result:
Result Proceed to
OK A
NG (to Power management control ECU main bus line) B
NG (to CAN No. 3 junction connector main bus line) C



A

REPLACE CAN NO. 2 JUNCTION CONNECTOR

B

REPAIR OR REPLACE CAN MAIN BUS LINE OR CONNECTOR (CAN NO. 2 J/C - POWER MANAGEMENT CONTROL ECU)

C

5.CHECK FOR OPEN IN SUB BUS 11 MAIN LINES (CAN NO. 2 J/C - CAN NO. 3 J/C)
5.CHECK FOR OPEN IN SUB BUS 11 MAIN LINES (CAN NO. 2 J/C - CAN NO. 3 J/C)
a.

Reconnect the wire harness connector to the CAN No. 2 junction connector.


b.

Disconnect the wire harness connector from the CAN No. 3 junction connector.


c.
C238890C17
0.181,0.161 0.331,0.313 0.149,0.153 10 *a 2.449,0.431 2.997,0.584 0.549,0.153 10 CANH*b 2.677,0.689 3.226,0.841 0.549,0.153 10 CANH*c 2.414,0.514 2.089,0.514 2.089,0.514 2.089,1.356 false 2.648,0.771 2.323,0.771 2.323,0.771 2.323,1.356 false 2.648,1.886 2.323,1.886 2.323,1.886 2.323,1.572 false 1.278,1.963 1.826,2.115 0.549,0.153 10 CANL*b 2.676,1.8 3.225,1.952 0.549,0.153 10 CANL*c 1.937,2.058 2.089,2.058 2.089,2.058 2.089,1.572 false 0.572,1.227 0.858,1.434 0.286,0.208 10 T15 0.475,1.187 0.953,1.432 0.477,0.245
*a Front view of wire harness connector
(to CAN No. 3 Junction Connector)
*b to CAN No. 4 Junction Connector
*c to CAN No. 2 Junction Connector


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
T15-9 (CANH) - T15-20 (CANL) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω
T15-11 (CANH) - T15-22 (CANL) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω



Result:
Result Proceed to
OK A
NG (to CAN No. 2 junction connector main bus line) B
NG (to CAN No. 4 junction connector main bus line) C



A

REPLACE CAN NO. 3 JUNCTION CONNECTOR

B

REPAIR OR REPLACE CAN MAIN BUS LINE OR CONNECTOR (CAN NO. 2 J/C - CAN NO. 3 J/C)

C

6.CHECK FOR OPEN IN SUB BUS 11 MAIN LINES (CAN NO. 3 J/C - CAN NO. 4 J/C)
6.CHECK FOR OPEN IN SUB BUS 11 MAIN LINES (CAN NO. 3 J/C - CAN NO. 4 J/C)
a.

Reconnect the wire harness connector to the CAN No. 3 junction connector.


b.

Disconnect the instrument panel wire from the CAN No. 4 junction connector.


c.
C183982C03
1.781,2.063 2.198,2.302 0.417,0.24 0.948,0.792 0.646,0.792 0.646,0.792 0.646,2.177 false 1.24,1.135 0.938,1.135 0.938,1.135 0.938,2.188 false 0.177,0.115 0.333,0.292 0.156,0.177 10 false *a 1,0.698 1.573,0.854 0.573,0.156 10 false CANH*b 1.292,1.042 1.854,1.198 0.563,0.156 10 false CANL*b 1.844,2.094 2.115,2.26 0.271,0.167 10 false T16
*a Rear view of wire harness connector
(to CAN No. 4 Junction Connector)
*b to CAN No. 3 Junction Connector


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
T16-3 (CANH) - T16-2 (CANL) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω



Result:
Result
OK
NG



OK

REPLACE CAN NO. 4 JUNCTION CONNECTOR

NG

REPAIR OR REPLACE CAN MAIN BUS LINE OR CONNECTOR (CAN NO. 3 J/C - CAN NO. 4 J/C)

7.CHECK FOR SHORT IN SUB BUS 11 LINES (POWER MANAGEMENT CONTROL ECU)
a.

Disconnect the power management control ECU connector.


b.
A204445C86
1.885,0.5 2.375,0.792 0.49,0.292 1.823,2.573 1.458,2.635 false 1.865,2.573 1.573,3.031 false 2.052,0.563 2.26,0.74 0.208,0.177 10 false I3 1.104,2.563 1.469,2.74 0.365,0.177 10 false CA2L 1.156,2.99 1.542,3.167 0.385,0.177 10 false CA2H 0.146,0.083 0.719,0.448 0.573,0.365 10 false *a
*a Rear view of wire harness connector
(to Power Management Control ECU)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
I3-34 (CA2H) - I3-35 (CA2L) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω



Result:
Result
OK
NG



OK

NG

8.CHECK FOR SHORT IN SUB BUS 11 LINES (CAN NO. 2 J/C - POWER MANAGEMENT CONTROL ECU)
8.CHECK FOR SHORT IN SUB BUS 11 LINES (CAN NO. 2 J/C - POWER MANAGEMENT CONTROL ECU)
a.

Reconnect the power management control ECU connector.


b.

Disconnect the wire harness connector from the CAN No. 2 junction connector.


c.
C238890C18
0.181,0.161 0.331,0.313 0.149,0.153 10 *a 2.45,0.161 2.999,0.313 0.549,0.153 10 CANH*b 2.562,0.418 3.11,0.571 0.549,0.153 10 CANH*c 2.678,0.676 3.226,0.829 0.549,0.153 10 CANH*d 2.42,0.256 2.096,0.256 2.096,0.256 2.096,1.356 false 2.534,0.514 2.209,0.514 2.209,0.514 2.209,1.356 false 2.648,0.771 2.323,0.771 2.323,0.771 2.323,1.356 false 2.678,1.793 3.226,1.946 0.549,0.153 10 CANL*d 2.648,1.886 2.323,1.886 2.323,1.886 2.323,1.572 false 0.587,1.793 1.136,1.946 0.549,0.153 10 CANL*b 1.258,1.886 2.098,1.886 2.098,1.886 2.098,1.572 false 1.387,1.965 1.935,2.118 0.549,0.153 10 CANL*c 2.057,2.058 2.209,2.058 2.209,2.058 2.209,1.572 false 0.405,1.148 0.819,1.392 0.414,0.244 0.447,1.18 0.739,1.343 0.292,0.163 10 O30
*a Front view of wire harness connector
(to CAN No. 2 Junction Connector)
*b to Blind Spot Monitor Sensor RH
*c to CAN No. 3 Junction Connector
*d to Power Management Control ECU


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
O30-9 (CANH) - O30-20 (CANL) Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
O30-10 (CANH) - O30-21 (CANL) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω
O30-11 (CANH) - O30-22 (CANL) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω



Result:
Result Proceed to
OK A
NG (to Power management control ECU main bus line) B
NG (to CAN No. 3 junction connector main bus line) C
NG (to Blind spot monitor sensor RH) D



A

REPLACE CAN NO. 2 JUNCTION CONNECTOR

B

REPAIR OR REPLACE CAN MAIN BUS LINE OR CONNECTOR (CAN NO. 2 J/C - POWER MANAGEMENT CONTROL ECU)

C

9.CHECK FOR SHORT IN SUB BUS 11 LINES (CAN NO. 2 J/C - CAN NO. 3 J/C)

D

11.CHECK FOR SHORT IN SUB BUS 11 LINES (ECUS)
9.CHECK FOR SHORT IN SUB BUS 11 LINES (CAN NO. 2 J/C - CAN NO. 3 J/C)
a.

Reconnect the wire harness connector to the CAN No. 2 junction connector.


b.

Disconnect the wire harness connector from the CAN No. 3 junction connector.


c.
C238890C19
0.479,1.135 0.896,1.375 0.417,0.24 2.427,0.271 2.104,0.271 2.104,0.271 2.104,1.365 false 2.542,0.521 2.219,0.521 2.219,0.521 2.219,1.365 false 2.656,0.781 2.333,0.781 2.333,0.781 2.333,1.365 false 2.646,1.896 2.323,1.896 2.323,1.896 2.323,1.583 false 1.26,1.896 2.094,1.896 2.094,1.896 2.094,1.583 false 2.052,2.073 2.208,2.073 2.208,2.073 2.208,1.583 false 0.177,0.156 0.323,0.313 0.146,0.156 10 false *a 2.5,0.198 3.052,0.354 0.552,0.156 10 false CANH*b 2.604,0.448 3.156,0.604 0.552,0.156 10 false CANH*c 2.719,0.708 3.271,0.865 0.552,0.156 10 false CANH*d 2.677,1.813 3.229,1.969 0.552,0.156 10 false CANL*d 0.74,1.823 1.292,1.979 0.552,0.156 10 false CANL*b 1.531,2.01 2.083,2.167 0.552,0.156 10 false CANL*c 0.573,1.188 0.969,1.521 0.396,0.333 10 false T15
*a Front view of wire harness connector
(to CAN No. 3 Junction Connector)
*b to CAN No. 4 Junction Connector
*c to Blind Spot Monitor Sensor LH
*d to CAN No. 2 Junction Connector


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
T15-9 (CANH) - T15-20 (CANL) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω
T15-10 (CANH) - T15-21 (CANL) Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
T15-11 (CANH) - T15-22 (CANL) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω



Result:
Result Proceed to
OK A
NG (to CAN No. 2 junction connector main bus line) B
NG (to CAN No. 4 junction connector main bus line) C
NG (to Blind spot monitor sensor LH) D



A

REPLACE CAN NO. 3 JUNCTION CONNECTOR

B

REPAIR OR REPLACE CAN MAIN BUS LINE OR CONNECTOR (CAN NO. 2 J/C - CAN NO. 3 J/C)

C

10.CHECK FOR SHORT IN SUB BUS 11 LINES (CAN NO. 3 J/C - CAN NO. 4 J/C)

D

11.CHECK FOR SHORT IN SUB BUS 11 LINES (ECUS)
10.CHECK FOR SHORT IN SUB BUS 11 LINES (CAN NO. 3 J/C - CAN NO. 4 J/C)
a.

Reconnect the wire harness connector to the CAN No. 3 junction connector.


b.

Disconnect the wire harness connector from the CAN No. 4 junction connector.


c.
C183982C03
1.781,2.063 2.198,2.302 0.417,0.24 0.948,0.792 0.646,0.792 0.646,0.792 0.646,2.177 false 1.24,1.135 0.938,1.135 0.938,1.135 0.938,2.188 false 0.177,0.115 0.333,0.292 0.156,0.177 10 false *a 1,0.698 1.573,0.854 0.573,0.156 10 false CANH*b 1.292,1.042 1.854,1.198 0.563,0.156 10 false CANL*b 1.844,2.094 2.115,2.26 0.271,0.167 10 false T16
*a Rear view of wire harness connector
(to CAN No. 4 Junction Connector)
*b to CAN No. 3 Junction Connector


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
T16-3 (CANH) - T16-2 (CANL) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω



Result:
Result
OK
NG



OK

REPLACE CAN NO. 4 JUNCTION CONNECTOR

NG

REPAIR OR REPLACE CAN MAIN BUS LINE OR CONNECTOR (CAN NO. 3 J/C - CAN NO. 4 J/C)

11.CHECK FOR SHORT IN SUB BUS 11 LINES (ECUS)
a.

Reconnect all wire harness connectors (CAN No. 2 junction connector and CAN No. 3 junction connector).


b.

Disconnect the connector that includes terminals CANH and CANL from the ECU (or sensor) to which the short-circuited branch line is connected.

Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>TERMINALS OF ECU


c.
A261175C13
1.813,0.583 2.313,0.875 0.5,0.292 1.604,1.083 1.698,1.083 1.698,1.083 1.823,1.688 false 2.552,1.083 2.448,1.083 2.448,1.083 2.229,1.688 false 1.531,2.917 1.625,2.917 1.625,2.917 1.813,1.906 false 2.167,2.906 2.083,2.906 2.083,2.906 1.865,1.906 false 0.063,0.021 0.271,0.24 0.208,0.219 10 false *a 2.573,1 2.99,1.156 0.417,0.156 10 false AM22 1.375,1 1.573,1.156 0.198,0.156 10 false E1 1.99,0.635 2.167,0.802 0.177,0.167 10 false I3 1.083,2.833 1.5,2.99 0.417,0.156 10 false CA2L 2.208,2.813 2.625,2.969 0.417,0.156 10 false CA2H
*a Component with harness connector
(Power Management Control ECU)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
I3-34 (CA2H) - I3-35 (CA2L) Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω


HINT:
·

If the resistance becomes normal (between 54 and 69 Ω) when the connector is disconnected from the ECU (or sensor), there may be a short in the ECU (or sensor).

·

If the resistance does not become normal (between 54 and 69 Ω) when the connector is disconnected from the ECU (or sensor), repair or replace the short-circuited branch line or connector.




Result:
Result
OK
NG



OK

REPLACE CORRESPONDING ECU

NG

REPAIR OR REPLACE CORRESPONDING ECU WIRE

12.CHECK FOR SHORT IN SUB BUS 11 LINE (CAN NO. 2 J/C)
a.

Disconnect the wire harness connector from the CAN No. 2 junction connector.


b.

Measure the resistance according to the value(s) in the table below.

C240196C06
2.052,3.771 2.417,3.979 0.365,0.208 2.552,1.469 2.917,1.677 0.365,0.208 3.438,3.615 3.333,3.031 3.333,3.031 3.115,3.031 false 4.188,4.198 4.406,4.448 4.406,4.448 4.688,4.448 false 3.99,1.698 4.24,1.552 4.24,1.552 4.396,1.552 false 4,1.854 4.25,1.958 4.25,1.958 4.406,1.958 false 3.896,1.865 4.344,2.302 4.344,2.302 4.573,2.302 false 3.896,1.698 4.354,1.188 4.354,1.188 4.552,1.188 false 3.802,1.698 4.125,0.875 4.125,0.875 4.74,0.875 false 3.802,1.865 4.177,2.635 4.177,2.635 4.771,2.635 false 2.24,0.604 2.531,0.896 0.292,0.292 10 false *a 2.24,2.854 2.531,3.146 0.292,0.292 10 false *1 4.771,0.76 5.479,1 0.708,0.24 10 false CANH*b 4.604,1.083 5.313,1.323 0.708,0.24 10 false CANH*c 4.469,1.448 5.177,1.688 0.708,0.24 10 false CANH*d 4.844,2.552 5.552,2.792 0.708,0.24 10 false CANL*b 4.615,2.219 5.323,2.458 0.708,0.24 10 false CANL*c 4.469,1.875 5.177,2.115 0.708,0.24 10 false CANL*d 2.604,1.479 2.927,1.698 0.323,0.219 10 false O30 2.146,3.781 2.5,4 0.354,0.219 10 false I39 2.865,2.958 3.156,3.177 0.292,0.219 10 false CG 4.74,4.354 5.115,4.563 0.375,0.208 10 false BAT
*1 DLC3 - -
*a Front view of wire harness connector
(to CAN No. 2 Junction Connector)
*b to Blind Spot Monitor Sensor RH
*c to CAN No. 3 Junction Connector *d to Power Management Control ECU


Standard Resistance:
Tester Connection Condition Specified Condition Purpose Connected to
O30-9 (CANH) - I39-4 (CG) Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher Inspection for CANH ground short Blind spot monitor sensor RH
O30-20 (CANL) - I39-4 (CG) Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher Inspection for CANL ground short
O30-10 (CANH) - I39-4 (CG) Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher Inspection for CANH ground short CAN No. 3 junction connector
O30-21 (CANL) - I39-4 (CG) Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher Inspection for CANL ground short
O30-11 (CANH) - I39-4 (CG) Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher Inspection for CANH ground short Power management control ECU
O30-22 (CANL) - I39-4 (CG) Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher Inspection for CANL ground short
O30-9 (CANH) - I39-16 (BAT) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher Inspection for CANH +B short Blind spot monitor sensor RH
O30-20 (CANL) - I39-16 (BAT) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher Inspection for CANL +B short
O30-10 (CANH) - I39-16 (BAT) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher Inspection for CANH +B short CAN No. 3 junction connector
O30-21 (CANL) - I39-16 (BAT) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher Inspection for CANL +B short
O30-11 (CANH) - I39-16 (BAT) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher Inspection for CANH +B short Power management control ECU
O30-22 (CANL) - I39-16 (BAT) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher Inspection for CANL +B short



Result:
Result Proceed to
OK A
NG (to Power management control ECU main bus line) B
NG (to CAN No. 3 junction connector main bus line) C
NG (to Blind spot monitor sensor RH) D


HINT:
·

It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 11 inspection.

·

Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check Sub Bus 11 inspection.




A

REPLACE CAN NO. 2 JUNCTION CONNECTOR

B

13.CHECK FOR SHORT IN SUB BUS 11 LINE (CAN NO. 2 J/C - POWER MANAGEMENT CONTROL ECU)

C

14.CHECK FOR SHORT IN SUB BUS 11 LINE (CAN NO. 2 J/C - CAN NO. 3 J/C)

D

16.CHECK FOR SHORT IN SUB BUS 11 LINE (ECUS)
13.CHECK FOR SHORT IN SUB BUS 11 LINE (CAN NO. 2 J/C - POWER MANAGEMENT CONTROL ECU)
a.

Disconnect the power management control ECU connector.


b.
A204445C85
1.917,2.969 2.406,3.26 0.49,0.292 1.833,2.354 1.625,2.198 false 2.229,2.365 2.458,2.24 false 1.823,2.573 1.594,2.604 false 1.865,2.573 1.646,2.896 false 2.094,3.021 2.344,3.25 0.25,0.229 10 false I3 0.115,0.115 0.625,0.365 0.51,0.25 10 false *a 1.417,2.104 1.833,2.365 0.417,0.26 10 false E1 2.5,2.146 2.979,2.417 0.479,0.271 10 false AM22 1.229,2.521 1.76,2.729 0.531,0.208 10 false CA2L 1.229,2.844 1.76,3.104 0.531,0.26 10 false CA2H
*a Rear view of wire harness connector
(to Power Management Control ECU)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition Purpose
I3-34 (CA2H) - I3-6 (E1) Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher Below 200 Ω: CANH ground short
I3-35 (CA2L) - I3-6 (E1) Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher Below 200 Ω: CANL ground short
I3-34 (CA2H) - I3-1 (AM22) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher Below 6 kΩ: CANH +B short
I3-35 (CA2L) - I3-1 (AM22) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher Below 6 kΩ: CANL +B short



Result:
Result
OK
NG


HINT:
·

It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 11 inspection.

·

Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check Sub Bus 11 inspection.




OK

NG

REPAIR OR REPLACE CAN MAIN BUS LINE OR CONNECTOR (CAN NO. 2 J/C - POWER MANAGEMENT CONTROL ECU)

14.CHECK FOR SHORT IN SUB BUS 11 LINE (CAN NO. 2 J/C - CAN NO. 3 J/C)
a.

Disconnect the wire harness connector from the CAN No. 3 junction connector.


b.

Measure the resistance according to the value(s) in the table below.

C240196C03
2.052,3.771 2.417,3.979 0.365,0.208 2.552,1.469 2.917,1.677 0.365,0.208 3.438,3.604 3.26,3.063 3.26,3.063 3.042,3.063 false 4.188,4.219 4.5,4.375 4.5,4.375 4.781,4.375 false 4.01,1.698 4.375,1.51 4.375,1.51 4.531,1.51 false 4.021,1.844 4.521,1.875 4.521,1.875 4.531,1.875 false 3.885,1.865 4.458,2.229 4.458,2.229 4.688,2.229 false 3.896,1.698 4.458,1.125 4.458,1.125 4.656,1.125 false 3.792,1.688 4.229,0.802 4.229,0.802 4.844,0.802 false 3.802,1.865 4.281,2.563 4.281,2.563 4.875,2.563 false 2.24,0.604 2.531,0.896 0.292,0.292 10 false *a 2.24,2.854 2.531,3.146 0.292,0.292 10 false *1 4.875,0.719 5.583,0.958 0.708,0.24 10 false CANH*b 4.677,1.031 5.385,1.271 0.708,0.24 10 false CANH*c 4.563,1.448 5.271,1.688 0.708,0.24 10 false CANH*d 4.906,2.51 5.615,2.75 0.708,0.24 10 false CANL*b 4.708,2.177 5.417,2.417 0.708,0.24 10 false CANL*c 4.563,1.802 5.271,2.042 0.708,0.24 10 false CANL*d 2.615,1.5 2.938,1.719 0.323,0.219 10 false T15 2.146,3.802 2.5,4.021 0.354,0.219 10 false I39 2.813,2.99 3.104,3.208 0.292,0.219 10 false CG 4.802,4.292 5.177,4.5 0.375,0.208 10 false BAT
*1 DLC3 - -
*a Front view of wire harness connector
(to CAN No. 3 Junction Connector)
*b to CAN No. 4 Junction Connector
*c to Blind Spot Monitor Sensor LH *d to CAN No. 2 Junction Connector


Standard Resistance:
Tester Connection Condition Specified Condition Purpose Connected to
T15-9 (CANH) - I39-4 (CG) Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher Inspection for CANH ground short CAN No. 4 junction connector
T15-20 (CANL) - I39-4 (CG) Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher Inspection for CANL ground short
T15-10 (CANH) - I39-4 (CG) Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher Inspection for CANH ground short Blind spot monitor sensor LH
T15-21 (CANL) - I39-4 (CG) Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher Inspection for CANL ground short
T15-11 (CANH) - I39-4 (CG) Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher Inspection for CANH ground short CAN No. 2 junction connector
T15-22 (CANL) - I39-4 (CG) Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher Inspection for CANL ground short
T15-9 (CANH) - I39-16 (BAT) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher Inspection for CANH +B short CAN No. 4 junction connector
T15-20 (CANL) - I39-16 (BAT) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher Inspection for CANL +B short
T15-10 (CANH) - I39-16 (BAT) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher Inspection for CANH +B short Blind spot monitor sensor LH
T15-21 (CANL) - I39-16 (BAT) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher Inspection for CANL +B short
T15-11 (CANH) - I39-16 (BAT) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher Inspection for CANH +B short CAN No. 2 junction connector
T15-22 (CANL) - I39-16 (BAT) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher Inspection for CANL +B short



Result:
Result Proceed to
OK A
NG (to CAN No. 2 junction connector main bus line) B
NG (to CAN No. 4 junction connector main bus line) C
NG (to Blind spot monitor sensor LH) D


HINT:
·

It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 11 inspection.

·

Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check Sub Bus 11 inspection.




A

REPLACE CAN NO. 3 JUNCTION CONNECTOR

B

REPAIR OR REPLACE CAN MAIN BUS LINE OR CONNECTOR (CAN NO. 2 J/C - CAN NO. 3 J/C)

C

15.CHECK FOR SHORT IN SUB BUS 11 LINE (CAN NO. 3 J/C - CAN NO. 4 J/C)

D

16.CHECK FOR SHORT IN SUB BUS 11 LINE (ECUS)
15.CHECK FOR SHORT IN SUB BUS 11 LINE (CAN NO. 3 J/C - CAN NO. 4 J/C)
a.

Disconnect the wire harness connector from the CAN No. 4 junction connector.


b.
C274535C01
1.51,0.302 1.948,0.646 0.438,0.344 1.563,2.146 2,2.49 0.438,0.344 2.104,1.302 2.104,1.875 2.104,1.875 2.385,1.875 false 1.823,1.302 1.823,1.875 1.823,1.875 1.406,1.875 false 2.563,4.094 2.552,3.823 false 1.677,3.073 1.667,2.656 1.667,2.656 1.469,2.656 false 2.448,1.802 3.01,2.125 0.563,0.323 10 false CANH 1,1.802 1.625,2.135 0.625,0.333 10 false CANL 0.135,0.146 0.563,0.448 0.427,0.302 10 false *a 2.458,4.135 3.021,4.458 0.563,0.323 10 false BAT 1.177,2.573 1.708,2.896 0.531,0.323 10 false CG 1.604,0.396 2.063,0.708 0.458,0.313 10 false T16 1.688,2.24 2.146,2.552 0.458,0.313 10 false I39 0.188,2.479 0.615,2.781 0.427,0.302 10 false *1
*1 DLC3
*a Front view of wire harness connector
(to CAN No. 4 Junction Connector)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition Purpose
T16-3 (CANH) - I39-4 (CG) Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher Below 200 Ω: CANH ground short
T16-2 (CANL) - I39-4 (CG) Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher Below 200 Ω: CANL ground short
T16-3 (CANH) - I39-16 (BAT) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher Below 6 kΩ: CANH +B short
T16-2 (CANL) - I39-16 (BAT) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher Below 6 kΩ: CANL +B short


HINT:
·

It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 11 inspection.

·

Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check Sub Bus 11 inspection.




Result:
Result
OK
NG



OK

REPLACE CAN NO. 4 JUNCTION CONNECTOR

NG

REPAIR OR REPLACE CAN MAIN BUS LINE OR CONNECTOR (CAN NO. 3 J/C - CAN NO. 4 J/C)

16.CHECK FOR SHORT IN SUB BUS 11 LINE (ECUS)
a.

Reconnect all wire harness connectors (CAN No. 2 junction connector and CAN No. 3 junction connector).


b.

Disconnect the connector that includes terminals CANH and CANL from the ECU to which the bus line shorted to B+ or shorted to GND is connected.


c.
A261175C13
1.813,0.583 2.313,0.875 0.5,0.292 1.604,1.083 1.698,1.083 1.698,1.083 1.823,1.688 false 2.552,1.083 2.448,1.083 2.448,1.083 2.229,1.688 false 1.531,2.917 1.625,2.917 1.625,2.917 1.813,1.906 false 2.167,2.906 2.083,2.906 2.083,2.906 1.865,1.906 false 0.063,0.021 0.271,0.24 0.208,0.219 10 false *a 2.573,1 2.99,1.156 0.417,0.156 10 false AM22 1.375,1 1.573,1.156 0.198,0.156 10 false E1 1.99,0.635 2.167,0.802 0.177,0.167 10 false I3 1.083,2.833 1.5,2.99 0.417,0.156 10 false CA2L 2.208,2.813 2.625,2.969 0.417,0.156 10 false CA2H
*a Component with harness connected
(Power Management Control ECU)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition Purpose
I3-34 (CA2H) - I3-6 (E1) Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher Below 200 Ω: CANH ground short
I3-35 (CA2L) - I3-6 (E1) Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher Below 200 Ω: CANL ground short
I3-34 (CA2H) - I3-1 (AM22) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher Below 6 kΩ: CANH +B short
I3-35 (CA2L) - I3-1 (AM22) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher Below 6 kΩ: CANL +B short



Result:
Result
OK
NG


HINT:
·

It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 11 inspection.

·

If the resistance becomes abnormal when an ECU connector is reconnected, there may be a short in the ECU. Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check Sub Bus 11 inspection.




OK

REPLACE CORRESPONDING ECU

NG

REPAIR OR REPLACE CORRESPONDING ECU WIRE