Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › from 2016.05
RM2040EQ _51 Engine / Hybrid System _014692 HYBRID / BATTERY CONTROL _0074885 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P3004-132  High Voltage Power Resource  


DESCRIPTION

Refer to the description for DTC P0AE6-225 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AE6-225).

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P3004-132 High Voltage Power Resource The inverter is not precharged.
·

Hybrid battery junction block assembly

·

No. 4 floor wire

·

Inverter with converter assembly

·

Power management control ECU

·

HV battery

·

Wire harness or connector


Does not come on Master Warning Light:
Comes on

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0AA6-526 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AA6-526).

Refer to the wiring diagram for DTC P0AE6-225 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AE6-225).

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.


·

When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.



NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.


d.

Check if DTCs are output.

Powertrain > Hybrid Control > Trouble Codes
50001 236
Result:
Result Proceed to
P3004-132 only is output. A
DTCs shown in Table 1 are output simultaneously. B
DTCs shown in Table 2 are output simultaneously. C


Table 1
DTC No. Relevant Diagnosis
P06E6-164 Sensor Power Supply "C" Circuit / Open
P0A1A-151, 658 Generator Control Module
P0A1B-786 Drive Motor "A" Control Module
P0A1D (all INF codes)*1 Hybrid Powertrain Control Module
P0ADB-227 Hybrid Battery Positive Contactor Control Circuit Low
P0ADC-226 Hybrid Battery Positive Contactor Control Circuit High
P0ADF-229 Hybrid Battery Negative Contactor Control Circuit Low
P0AE0-228 Hybrid Battery Negative Contactor Control Circuit High
P0AE6-225 Hybrid Battery Precharge Contactor Control Circuit Low
P0AE7-224 Hybrid Battery Precharge Contactor Control Circuit High
P0C76-523 Hybrid Battery System Discharge Time Too Long
P0CA3-442 DC/DC Converter Step Up Voltage Performance
P0D2E-586 Drive Motor "A" Inverter Voltage Sensor Circuit Range / Performance
P0D2F-266 Drive Motor "A" Inverter Voltage Sensor Circuit Low
P0D30-267 Drive Motor "A" Inverter Voltage Sensor Circuit High
P1C2A-155 Generator A/D Converter Circuit
P1C73-512 Sensor Standard Voltage "F" Circuit / Open
P1CA6-156 Generator Control Module Malfunction
P1CA7-193 Drive Motor Control Module Malfunction
P2511-149 ECM/PCM Power Relay Sense Circuit Intermittent
P3004-131, 800, 801 High Voltage Power Resource
P3133-659 Communication Error from Generator to Drive Motor "A"
P3134-661 Communication Error from Drive Motor "A" to Generator
P324E-788 MG-ECU Power Relay Intermittent Circuit
U0110 (all INF codes)*1 Lost Communication with Drive Motor Control Module "A"

Table 2
DTC No. Relevant Diagnosis
P0A95-123 High Voltage Fuse
P0ABF-123 Hybrid Battery Pack Current Sensor Circuit
P0AC0-123 Hybrid Battery Pack Current Sensor Circuit Range / Performance
P0AC1-123 Hybrid Battery Pack Current Sensor "A" Circuit Low
P0AC2-123 Hybrid Battery Pack Current Sensor "A" Circuit High
P0AFC-123 Hybrid Battery Pack Sensor Module
P0B3D-123 Hybrid Battery Voltage Sensor "A" Circuit Low
P0B42-123 Hybrid Battery Voltage Sensor "B" Circuit Low
P0B47-123 Hybrid Battery Voltage Sensor "C" Circuit Low
P0B4C-123 Hybrid Battery Voltage Sensor "D" Circuit Low
P0B51-123 Hybrid Battery Voltage Sensor "E" Circuit Low
P0B56-123 Hybrid Battery Voltage Sensor "F" Circuit Low
P0B5B-123 Hybrid Battery Voltage Sensor "G" Circuit Low
P0B60-123 Hybrid Battery Voltage Sensor "H" Circuit Low
P0B65-123 Hybrid Battery Voltage Sensor "I" Circuit Low
P0B6A-123 Hybrid Battery Voltage Sensor "J" Circuit Low
P0B6F-123 Hybrid Battery Voltage Sensor "K" Circuit Low
P0B74-123 Hybrid Battery Voltage Sensor "L" Circuit Low
P0B79-123 Hybrid Battery Voltage Sensor "M" Circuit Low
P0B7E-123 Hybrid Battery Voltage Sensor "N" Circuit Low
P0B83-123 Hybrid Battery Voltage Sensor "O" Circuit Low
P0B88-123 Hybrid Battery Voltage Sensor "P" Circuit Low
P0B8D-123 Hybrid Battery Voltage Sensor "Q" Circuit Low
P0B92-123 Hybrid Battery Voltage Sensor "R" Circuit Low
P308A-123 Hybrid Battery Voltage Sensor All Circuits Low
U029A-123 Lost Communication with Hybrid Battery Pack Sensor Module

HINT:
·

*1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.

·

P3004-132 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.




e.

Turn the power switch off.



A

2.CHECK FREEZE FRAME DATA (HYBRID CONTROL)

B

C

2.CHECK FREEZE FRAME DATA (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.


d.

Read the freeze frame data of DTC P3004-132.

Result:
Result Proceed to
All of the following conditions are met:
·

Difference between HV battery voltage (Power Resource VB) and pre-boost voltage (VL-Voltage before Boosting) is 40 V or less.

·

Difference between HV battery voltage (Power Resource VB) and post-boost voltage (VH-Voltage after Boosting) is more than 40 V.

·

Difference between pre-boost voltage (VL-Voltage before Boosting) and post-boost voltage (VH-Voltage after Boosting) is more than 50 V.


A
In addition to the above conditions, HV battery current (Batt Pack Current Val) is 3 A or more. B
Other than above C



e.

Turn the power switch off.



A

B

C

3.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)
3.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)

OK

4.CHECK INVERTER WITH CONVERTER ASSEMBLY (NO. 4 FLOOR WIRE CONNECTOR CONNECTION CONDITION)

NG

CONNECT SECURELY

4.CHECK INVERTER WITH CONVERTER ASSEMBLY (NO. 4 FLOOR WIRE CONNECTOR CONNECTION CONDITION)

A

5.CHECK HV BATTERY JUNCTION BLOCK ASSEMBLY (NO. 4 FLOOR WIRE CONNECTOR CONNECTION CONDITION)

B

REPLACE MALFUNCTIONING PARTS

C

CONNECT SECURELY

5.CHECK HV BATTERY JUNCTION BLOCK ASSEMBLY (NO. 4 FLOOR WIRE CONNECTOR CONNECTION CONDITION)

A

6.CHECK NO. 4 FLOOR WIRE (INVERTER WITH CONVERTER ASSEMBLY - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY)

B

REPLACE MALFUNCTIONING PARTS

C

CONNECT SECURELY

6.CHECK NO. 4 FLOOR WIRE (INVERTER WITH CONVERTER ASSEMBLY - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY)

OK

7.CHECK HV BATTERY JUNCTION BLOCK ASSEMBLY (HV BATTERY HIGH VOLTAGE TERMINAL CONNECTION CONDITION)

NG

7.CHECK HV BATTERY JUNCTION BLOCK ASSEMBLY (HV BATTERY HIGH VOLTAGE TERMINAL CONNECTION CONDITION)

A

8.CHECK HV BATTERY

B

REPLACE MALFUNCTIONING PARTS

C

CONNECT SECURELY

8.CHECK HV BATTERY

OK

9.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY)

NG

9.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY)

OK

10.INSPECT HV BATTERY JUNCTION BLOCK ASSEMBLY (SMRB)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

10.INSPECT HV BATTERY JUNCTION BLOCK ASSEMBLY (SMRB)

OK

11.INSPECT HV BATTERY JUNCTION BLOCK ASSEMBLY (SMRP)

NG

REPLACE HV BATTERY JUNCTION BLOCK ASSEMBLY

11.INSPECT HV BATTERY JUNCTION BLOCK ASSEMBLY (SMRP)

OK

12.CHECK FOR INTERMITTENT PROBLEMS

NG

REPLACE HV BATTERY JUNCTION BLOCK ASSEMBLY

12.CHECK FOR INTERMITTENT PROBLEMS

NEXT

13.CLEAR DTC
13.CLEAR DTC
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.


d.

Read and record the DTCs and freeze frame data.


e.

Clear DTCs and freeze frame data.

Powertrain > Hybrid Control > Clear DTCs
50002 236

f.

Turn the power switch off.


Result:
Proceed to
NEXT



NEXT

14.CHECK DTC OUTPUT (HYBRID CONTROL)
14.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (READY).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.


d.

Check for DTCs.

Powertrain > Hybrid Control > Trouble Codes
50001 236
Result:
Result Proceed to
No DTCs are output. A
DTC P3004-131 is output. B
DTC P3004-132 is output. C


HINT:

Because P3004-131 uses 2-trip detection logic, the DTC detection conditions need to be met 2 times.



e.

Turn the power switch off.



A

B

C