Home › Power Source / Network › NETWORKING › CAN COMMUNICATION SYSTEM

DTC    U0100    Lost Communication with ECM / PCM "A"

DTC    U0129    Lost Communication with Brake System Control Module

DTC    U0293    Lost Communication with HV ECU

for Preparation Click here


DESCRIPTION

  1. The power management control ECU communicates with the ECM and brake booster with master cylinder assembly (skid control ECU). When the power management control ECU does not receive data from the ECM or brake booster with master cylinder assembly (skid control ECU), the power management control ECU stores DTC U0100 or U0129.
  2. The ECM communicates with the power management control ECU. When the ECM does not receive data from the power management control ECU, the ECM stores DTC U0293.
  3. The brake booster with master cylinder assembly (skid control ECU) communicates with the power management control ECU. When the brake booster with master cylinder assembly (skid control ECU) does not receive data from the power management control ECU, the brake booster with master cylinder assembly (skid control ECU) stores DTC U0293.

DTC No.
DTC Detection Condition
Trouble Area
U0100
The power management control ECU does not receive data from the ECM.
  1. Open or short in sub bus 15 main line or connector
  2. Open or short in sub bus 15 branch line or connector
  3. Power source circuit of power management control ECU
  4. Power management control ECU
  5. Power source circuit of ECM
  6. ECM
  7. Open or short in CAN No. 1 junction connector
U0129
The power management control ECU does not receive data from the brake booster with master cylinder assembly (skid control ECU).
  1. Open or short in sub bus 15 main line or connector
  2. Open or short in sub bus 15 branch line or connector
  3. Power source circuit of power management control ECU
  4. Power management control ECU
  5. Power source circuit of brake booster with master cylinder assembly (skid control ECU)
  6. Brake booster with master cylinder assembly (skid control ECU)
  7. Open or short in CAN No. 1 junction connector
U0293
  1. The ECM does not receive data from the power management control ECU.
  2. The brake booster with master cylinder assembly (skid control ECU) does not receive data from the power management control ECU.
  1. Open or short in sub bus 15 main line or connector
  2. Open or short in sub bus 15 branch line or connector
  3. Power source circuit of ECM
  4. ECM
  5. Power source circuit of power management control ECU
  6. Power management control ECU
  7. Power source circuit of brake booster with master cylinder assembly (skid control ECU)
  8. Brake booster with master cylinder assembly (skid control ECU)
  9. Open or short in CAN No. 1 junction connector

HINT:
This diagnosis procedure is for when DTC U0100, U0129 and U0293 are output at the same time.


WIRING DIAGRAM


C244197E03


INSPECTION PROCEDURE

NOTICE:
  1. Before measuring the resistance of the CAN bus, turn the power switch off and leave the vehicle for 1 minute or more without operating the key, switches or opening or closing the doors. After that, disconnect the cable from the negative (-) auxiliary battery terminal and leave the vehicle for 1 minute or more before measuring the resistance.
  2. After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (Click here).
  3. Because the order of diagnosis is important to allow correct diagnosis, make sure to begin troubleshooting using How to Proceed with Troubleshooting when CAN communication system related DTCs are output (Click here).
  4. After performing repairs, perform the DTC check procedure and confirm that the DTCs are not output again.
  5. DTC check procedure: Turn the power switch on (IG) and wait at least 60 seconds.
  6. After the repair, perform Communication Bus Check and check that all the ECUs and sensors connected to the CAN communication system are displayed (Click here).

HINT:
  1. Operating the power switch, any other switches or a door triggers related ECU and sensor communication on the CAN. This communication will cause the resistance value to change.
  2. Even after DTCs are cleared, if a DTC is stored again after driving the vehicle for a while, the malfunction may be occurring due to vibration of the vehicle. In such a case, wiggling the ECUs or wire harness while performing the inspection below may help determine the cause of the malfunction.

1.RECONFIRM DTC OUTPUT
  1. Check if Hybrid Control of the power management control ECU outputs only DTC U0129.

    HINT:
    If the power management control ECU outputs only DTC U0129, troubleshoot DTC U0129 and check the branch circuit of sub bus 15.

    Result:
    Result
    Proceed to
    The power management control ECU outputs DTC U0129 and other DTCs.
    (Intelligent tester display: Hybrid Control)
    A
    The power management control ECU outputs only DTC U0129.
    (Intelligent tester display: Hybrid Control)
    B



B
GO TO DIAGNOSIS PROCEDURE INDICATED BY OUTPUT DTC
A


2.CHECK SUB BUS 15
  1. Disconnect the cable from the negative (-) auxiliary battery terminal.



    A261175E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Result
    I4-31 (CA3P) - I4-30 (CA3N)
    Cable disconnected from negative (-) auxiliary battery terminal
    54 to 69 Ω
    Below 54 Ω: Short circuit between bus lines
    70 Ω or higher: Open circuit in a main bus line
    I4-31 (CA3P) - I4-4 (E12)
    Cable disconnected from negative (-) auxiliary battery terminal
    200 Ω or higher
    Below 200 Ω: CANH ground short
    I4-30 (CA3N) - I4-4 (E12)
    Cable disconnected from negative (-) auxiliary battery terminal
    200 Ω or higher
    Below 200 Ω: CANL ground short

    Text in Illustration 
    *a
    Component with harness connected
    (Power Management Control ECU)

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Result
    I4-31 (CA3P) - I4-7 (AM21)
    Cable disconnected from negative (-) auxiliary battery terminal
    6 kΩ or higher
    Below 6 kΩ: CANH +B short
    I4-30 (CA3N) - I4-7 (AM21)
    Cable disconnected from negative (-) auxiliary battery terminal
    6 kΩ or higher
    Below 6 kΩ: CANL +B short

    HINT:
    1. When the values are as specified, clear and recheck for DTCs. When no DTCs are output, check for malfunctions such as damage or improper connection of the relevant connectors.
    2. If DTCs are output although the bus circuit is normal and DTCs were cleared, replace the power management control ECU.

    Result:
    Result
    Proceed to
    OK
    A
    NG (Open circuit in CAN main bus line)
    B
    NG (Short circuit between bus lines)
    C
    1. NG (Ground short)
    2. NG (+B short)
    D



B
Go to step 3

C
Go to step 6

D
Go to step 10
A

REPLACE POWER MANAGEMENT CONTROL ECU (Click here)  

3.CHECK FOR OPEN IN SUB BUS 15 MAIN LINES (POWER MANAGEMENT CONTROL ECU)


    A204446E37
  1. Disconnect the power management control ECU connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    I4-31 (CA3P) - I4-30 (CA3N)
    Cable disconnected from negative (-) auxiliary battery terminal
    108 to 132 Ω

    Text in Illustration  
    *a
    Rear view of wire harness connector
    (to Power Management Control ECU)



NG
Go to step 4
OK

REPLACE POWER MANAGEMENT CONTROL ECU (Click here)  

4.CHECK FOR OPEN IN SUB BUS 15 MAIN LINES (CAN NO. 1 J/C)
  1. Reconnect the power management control ECU connector.



    C234634E65
  1. Disconnect the CAN No. 1 junction connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Connected to
    A72-2 (CANH) - A72-8 (CANL)
    Cable disconnected from negative (-) auxiliary battery terminal
    108 to 132 Ω
    ECM
    A72-3 (CANH) - A72-9 (CANL)
    Cable disconnected from negative (-) auxiliary battery terminal
    108 to 132 Ω
    Power management control ECU

    Text in Illustration  
    *a
    Front view of wire harness connector
    (to CAN No. 1 Junction Connector)
    *b
    to ECM
    *c
    to Power Management Control ECU

Result:
Result
Proceed to
OK
A
NG (Open circuit in power management control ECU CAN main bus line)
B
NG (Open circuit in ECM CAN main bus line)
C



B
REPAIR OR REPLACE CAN MAIN BUS LINE OR CONNECTOR (POWER MANAGEMENT CONTROL ECU - CAN NO. 1 J/C)

C
Go to step 5
A

REPLACE CAN NO. 1 JUNCTION CONNECTOR 

5.CHECK FOR OPEN IN SUB BUS 15 MAIN LINES (ECM - CAN NO. 1 J/C)
  1. Reconnect the CAN No. 1 junction connector.



    C239823E07
  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A25-12 (CANP) - A25-25 (CANN)
    Cable disconnected from negative (-) auxiliary battery terminal
    108 to 132 Ω

    Text in Illustration  
    *a
    Front view of wire harness connector
    (to ECM)



NG
REPAIR OR REPLACE CAN MAIN BUS LINE OR CONNECTOR (ECM - CAN NO. 1 J/C)
OK

REPLACE ECM (Click here)  

6.CHECK FOR SHORT IN SUB BUS 15 LINES (POWER MANAGEMENT CONTROL ECU)


    A204446E37
  1. Disconnect the power management control ECU connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    I4-31 (CA3P) - I4-30 (CA3N)
    Cable disconnected from negative (-) auxiliary battery terminal
    108 to 132 Ω

    Text in Illustration  
    *a
    Rear view of wire harness connector
    (to Power Management Control ECU)



NG
Go to step 7
OK

REPLACE POWER MANAGEMENT CONTROL ECU (Click here)  

7.CHECK FOR SHORT IN SUB BUS 15 LINES (CAN NO. 1 J/C)
  1. Reconnect the power management control ECU connector.



    C234634E66
  1. Disconnect the CAN No. 1 junction connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Connected to
    A72-1 (CANH) - A72-7 (CANL)
    Cable disconnected from negative (-) auxiliary battery terminal
    200 Ω or higher
    Brake booster with master cylinder assembly (skid control ECU)
    A72-2 (CANH) - A72-8 (CANL)
    Cable disconnected from negative (-) auxiliary battery terminal
    108 to 132 Ω
    ECM
    A72-3 (CANH) - A72-9 (CANL)
    Cable disconnected from negative (-) auxiliary battery terminal
    108 to 132 Ω
    Power management control ECU

    Text in Illustration  
    *a
    Front view of wire harness connector
    (to CAN No. 1 Junction Connector)
    *b
    to ECM
    *c
    to Power Management Control ECU
    *d
    to Brake Booster with Master Cylinder Assembly (skid control ECU)

    Result:
    Result
    Proceed to
    OK
    A
    NG (Short circuit between bus lines in power management control ECU CAN main bus line)
    B
    NG (Short circuit between bus lines in ECM CAN main bus line)
    C
    NG (Short circuit between bus lines in brake booster with master cylinder assembly (skid control ECU) CAN branch line)
    D



B
REPAIR OR REPLACE CAN MAIN BUS LINE OR CONNECTOR (POWER MANAGEMENT CONTROL ECU - CAN NO. 1 J/C)

C
Go to step 8

D
Go to step 9
A

REPLACE CAN NO. 1 JUNCTION CONNECTOR 

8.CHECK FOR SHORT IN SUB BUS 15 LINES (ECM - CAN NO. 1 J/C)
  1. Reconnect the CAN No. 1 junction connector.



    C239823E07
  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A25-12 (CANP) - A25-25 (CANN)
    Cable disconnected from negative (-) auxiliary battery terminal
    108 to 132 Ω

    Text in Illustration  
    *a
    Front view of wire harness connector
    (to ECM)



NG
REPAIR OR REPLACE CAN MAIN BUS LINE OR CONNECTOR (ECM - CAN NO. 1 J/C)
OK

REPLACE ECM (Click here)  

9.CHECK FOR SHORT IN SUB BUS 15 LINES (BRAKE BOOSTER WITH MASTER CYLINDER - CAN NO. 1 J/C)
  1. Reconnect the CAN No. 1 junction connector.



    C209401E88
  1. Disconnect the brake booster with master cylinder assembly (skid control ECU) connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A28-35 (CA2H) - A28-34 (CA2L)
    Cable disconnected from negative (-) auxiliary battery terminal
    54 to 69 Ω

    Text in Illustration  
    *a
    Front view of wire harness connector
    (to Brake Booster with Master Cylinder Assembly (Skid Control ECU))

    Result:
    Result
    Proceed to
    OK (for LHD)
    A
    OK (for RHD)
    B
    NG
    C



B
REPLACE BRAKE BOOSTER WITH MASTER CYLINDER ASSEMBLY (for RHD) (Click here)

C
REPAIR OR REPLACE CAN BRANCH LINE OR CONNECTOR (BRAKE BOOSTER WITH MASTER CYLINDER ASSEMBLY)
A

REPLACE BRAKE BOOSTER WITH MASTER CYLINDER ASSEMBLY (for LHD) (Click here)  

10.CHECK FOR SHORT IN SUB BUS 15 LINES (CAN NO. 1 J/C)


    C234634E66
  1. Disconnect the CAN No. 1 junction connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Connected to
    A72-1 (CANH) - GND
    Cable disconnected from negative (-) auxiliary battery terminal
    200 Ω or higher
    Brake booster with master cylinder assembly (skid control ECU)
    A72-7 (CANL) - GND
    A72-2 (CANH) - GND
    Cable disconnected from negative (-) auxiliary battery terminal
    200 Ω or higher
    ECM
    A72-8 (CANL) - GND
    A72-3 (CANH) - GND
    Cable disconnected from negative (-) auxiliary battery terminal
    200 Ω or higher
    Power management control ECU
    A72-9 (CANL) - GND
    A72-1 (CANH) - +B
    Cable disconnected from negative (-) auxiliary battery terminal
    6 kΩ or higher
    Brake booster with master cylinder assembly (skid control ECU)
    A72-7 (CANL) - +B
    A72-2 (CANH) - +B
    Cable disconnected from negative (-) auxiliary battery terminal
    6 kΩ or higher
    ECM
    A72-8 (CANL) - +B
    A72-3 (CANH) - +B
    Cable disconnected from negative (-) auxiliary battery terminal
    6 kΩ or higher
    Power management control ECU
    A72-9 (CANL) - +B

    HINT:
    It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 15 inspection. Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check Sub Bus 15 inspection.

    Text in Illustration  
    *a
    Front view of wire harness connector
    (to CAN No. 1 Junction Connector)
    *b
    to ECM
    *c
    to Power Management Control ECU
    *d
    to Brake Booster with Master Cylinder Assembly (Skid Control ECU)

    Result:
    Result
    Proceed to
    OK
    A
    1. NG (Ground short in power management control ECU CAN main bus line)
    2. NG (+B short in power management control ECU CAN main bus line)
    B
    1. NG (Ground short in ECM CAN main bus line)
    2. NG (+B short in ECM CAN main bus line)
    C
    1. NG (Ground short in brake booster with master cylinder assembly (skid control ECU) CAN branch line)
    2. NG (+B short in brake booster with master cylinder assembly (skid control ECU) CAN branch line)
    D



B
Go to step 11

C
Go to step 12

D
Go to step 13
A

REPLACE CAN NO. 1 JUNCTION CONNECTOR 

11.CHECK FOR SHORT IN SUB BUS 15 LINES (POWER MANAGEMENT CONTROL ECU - CAN NO. 1 J/C)


    A204446E37
  1. Disconnect the power management control ECU connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    I4-31 (CA3P) - GND
    Cable disconnected from negative (-) auxiliary battery terminal
    200 Ω or higher
    I4-30 (CA3N) - GND
    I4-31 (CA3P) - +B
    Cable disconnected from negative (-) auxiliary battery terminal
    6 kΩ or higher
    I4-30 (CA3N) - +B

    HINT:
    It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 15 inspection. Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check Sub Bus 15 inspection.

    Text in Illustration  
    *a
    Rear view of wire harness connector
    (to Power Management Control ECU)



NG
REPAIR OR REPLACE CAN MAIN BUS LINE OR CONNECTOR (POWER MANAGEMENT CONTROL ECU - CAN NO. 1 J/C)
OK

REPLACE POWER MANAGEMENT CONTROL ECU (Click here)  

12.CHECK FOR SHORT IN SUB BUS 15 LINES (ECM - CAN NO. 1 J/C)


    C239823E07
  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A25-12 (CANP) - GND
    Cable disconnected from negative (-) auxiliary battery terminal
    200 Ω or higher
    A25-25 (CANN) - GND
    A25-12 (CANP) - +B
    Cable disconnected from negative (-) auxiliary battery terminal
    6 kΩ or higher
    A25-25 (CANN) - +B

    HINT:
    It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 15 inspection. Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check Sub Bus 15 inspection.

    Text in Illustration  
    *a
    Front view of wire harness connector
    (to ECM)



NG
REPAIR OR REPLACE CAN MAIN BUS LINE OR CONNECTOR (ECM - CAN NO. 1 J/C)
OK

REPLACE ECM (Click here)  

13.CHECK FOR SHORT IN SUB BUS 15 LINES (BRAKE BOOSTER WITH MASTER CYLINDER - CAN NO. 1 J/C)


    C209401E88
  1. Disconnect the brake booster with master cylinder assembly (skid control ECU) connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A28-35 (CA2H) - GND
    Cable disconnected from negative (-) auxiliary battery terminal
    200 Ω or higher
    A28-34 (CA2L) - GND
    A28-35 (CA2H) - +B
    Cable disconnected from negative (-) auxiliary battery terminal
    6 kΩ or higher
    A28-34 (CA2L) - +B

    HINT:
    It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 15 inspection. Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check Sub Bus 15 inspection.

    Text in Illustration  
    *a
    Front view of wire harness connector
    (to Brake Booster with Master Cylinder Assembly (Skid Control ECU))

    Result:
    Result
    Proceed to
    OK (for LHD)
    A
    OK (for RHD)
    B
    NG
    C



B
REPLACE BRAKE BOOSTER WITH MASTER CYLINDER ASSEMBLY (for RHD) (Click here)

C
REPAIR OR REPLACE CAN BRANCH LINE OR CONNECTOR (BRAKE BOOSTER WITH MASTER CYLINDER ASSEMBLY)
A

REPLACE BRAKE BOOSTER WITH MASTER CYLINDER ASSEMBLY (for LHD) (Click here)