DTC
P223711 O2 Sensor Positive Current Control Bank 1 Sensor 1 Circuit Short to Ground | |
DTC
P223712 O2 Sensor Positive Current Control Bank 1 Sensor 1 Circuit Short to Battery |
DTC
P223714 O2 Sensor Positive Current Control Bank 1 Sensor 1 Circuit Short to Ground or Open |
DTC
P223716 O2 Sensor Positive Current Control Bank 1 Sensor 1 Circuit Voltage Below Threshold |
DTC
P223717 O2 Sensor Positive Current Control Bank 1 Sensor 1 Circuit Voltage Above Threshold |
DTC
P22371A O2 Sensor Positive Current Control Bank 1 Sensor 1 Circuit Resistance Below Threshold |
DTC
P225111 O2 Sensor Negative Current Control Bank 1 Sensor 1 Circuit Short to Ground |
DTC
P225112 O2 Sensor Negative Current Control Bank 1 Sensor 1 Circuit Short to Battery |
DTC No.
| DTC Detection Condition
| Trouble Area
|
P223711
| The A1A+ voltage is 0.5 V or less for 5 seconds or more (2 trip detection logic).
| - Open or short in air fuel ratio sensor (sensor 1) circuit
- Air fuel ratio sensor (sensor 1)
- ECM
|
P223712
| The A1A+ voltage is higher than 4.5 V for 5 seconds or more (2 trip detection logic).
| - Short in air fuel ratio sensor (sensor 1) circuit
- Air fuel ratio sensor (sensor 1)
- ECM
|
P223714
| An open or ground short in the circuit between terminals A1A+ and A1A- of the air fuel ratio sensor while the engine is running (2 trip detection logic).
| - Open or short in air fuel ratio sensor (sensor 1) circuit
- Air fuel ratio sensor (sensor 1)
- ECM
|
P223716
| Difference between terminals A1A+ and A1A- is 0.1 V or less for 5 seconds or more (2 trip detection logic).
| - Open or short in air fuel ratio sensor (sensor 1) circuit
- Air fuel ratio sensor (sensor 1)
- ECM
|
P223717
| Difference between terminals A1A+ and A1A- is 0.8 V or higher for 5 seconds or more (2 trip detection logic).
| - Open or short in air fuel ratio sensor (sensor 1) circuit
- Air fuel ratio sensor (sensor 1)
- ECM
|
P22371A
| The air fuel ratio sensor admittance is less than 0.0074 1/Ω (2 trip detection logic).
| - Open or short in air fuel ratio sensor (sensor 1) circuit
- Air fuel ratio sensor (sensor 1)
- ECM
|
P225111
| The A1A- voltage is 0.5 V or less for 5 seconds or more (2 trip detection logic).
| - Open or short in air fuel ratio sensor (sensor 1) circuit
- Air fuel ratio sensor (sensor 1)
- ECM
|
P225112
| The A1A- voltage is higher than 4.5 V for 5 seconds or more (2 trip detection logic).
| - Short in air fuel ratio sensor (sensor 1) circuit
- Air fuel ratio sensor (sensor 1)
- ECM
|