| B1411
|
Room Temperature Sensor Circuit
|
Open or short in room temperature sensor circuit
|
|
| B1412
|
Ambient Temperature Sensor Circuit
|
Open or short in ambient temperature sensor circuit
|
|
| B1413
|
Evaporator Temperature Circuit or Evaporator Fin Thermistor
|
Open or short in evaporator temperature sensor circuit
|
|
| B1422
|
Compressor Lock
|
Open or short in A/C lock sensor circuit
|
|
| B1423
|
Open in Pressure Sensor Circuit / Abnormal Refrigerant Pressure
|
·
Open or short in air conditioner pressure sensor circuit
·
Refrigerant pressure on high pressure side is extremely low (0.176 MPaG (1.8 kgf/cm2, 26 psi) or less) or extremely high (3.025 MPaG (30.8 kgf/cm2, 439 psi) or more)
|
|
| B1441
|
Air Mix Damper Control Servo Motor Circuit (Passenger Side)
|
Air mix damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix)
|
|
| B1442
|
Air Inlet Damper Control Servo Motor Circuit
|
Air inlet damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 blower damper servo sub-assembly
|
|
| B1443
|
Air Outlet Damper Control Servo Motor Circuit
|
Air outlet damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 air conditioning radiator damper servo sub-assembly (mode)
|
|
| B1446
|
Air Mix Damper Control Servo Motor Circuit (Driver Side)
|
Air mix damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix)
|
|
| B1447
|
Air Mix Damper Control Servo Motor Circuit (Rear)
|
Air mix damper position sensor value does not change even if air conditioning amplifier assembly operates No. 3 air conditioning radiator damper servo sub-assembly
|
|
| B1449
|
Air Outlet Damper Control Servo Motor Circuit (Rear)
|
Air outlet damper position sensor value does not change even if air conditioning amplifier assembly operates No. 2 air conditioning radiator damper servo sub-assembly
|
|
| B1451
|
Compressor Solenoid Circuit
|
Open or short in compressor solenoid circuit
|
|
| B1497
|
Communication Malfunction (Bus Ic)
|
Error or open in communication line
|
|
| B14B2
|
Lost Communication with Front Panel LIN
|
Lost communication with air conditioning control assembly
|
|
| B14B3
|
Lost Communication with Rear Panel LIN
|
Lost communication with cooler control switch assembly
|
|
| B14B8
|
Refrigerant Shortage
|
The following condition is detected in the normal operation refrigerant shortage check:
Amount of refrigerant is insufficient
|
|
| B14B9
|
Open in Ion Generator Circuit
|
Open or short in ion generator circuit
|
|
| B14BD
|
Refrigerant Overabundance Filling Malfunction
|
All of the following conditions are met 2 times or more in the same trip:
·
The vehicle speed is 20 km/h or more
·
The amount of compressor oil is within the insufficient compressor oil range for 60 seconds or more
|
|
| U0100
|
Lost Communication With ECM/PCM "A"
|
No communication with ECM
|
|
| U0131
|
Lost Communication With Power Steering Control Module
|
No communication with power steering ECU (rack and pinion power steering gear assembly)
|
|
| U0142
|
Lost Communication With Body Control Module "B"
|
No communication with main body ECU (multiplex network body ECU)
|
|
| U0151
|
Lost Communication With Restraints Control Module
|
No communication with airbag sensor assembly
|
|
| U0155
|
Lost Communication With Instrument Panel Cluster (IPC) Control Module
|
No communication with combination meter assembly
|
|
| U0163
|
Lost Communication With Navigation Control Module
|
No communication with air conditioning control panel (radio and display receiver assembly)
|
|