Home › Engine / Hybrid System › N04C-UH (ENGINE CONTROL) › ECD SYSTEM
RM2850E _51 Engine / Hybrid System _073137 N04C-UH ENGINE CONTROL _0355844 ECD SYSTEM J

N04C-UH ENGINE CONTROL  ECD SYSTEM  Clogging by DPF Catalytic Converter  


DESCRIPTION

The differential pressure sensor is mounted on the exhaust pipe. It measures the pressure before and after the DPF catalytic converter (monolithic converter assembly), converts the difference in pressure into a voltage signal, and outputs it to the ECM. Based on this signal, the ECM determines whether the DPF catalytic converter is clogged. If the DPF catalytic converter is clogged, the ECM activates the forcible regeneration function of the DPF catalytic converter. In some cases, the forcible regeneration function may not be conducted depending on the driving conditions. In such cases, the indicator light in the combination meter and the DPF switch light blink to inform the driver that the converter is clogged. When the driver presses the DPF switch, the forcible regeneration function signal (RGSW) is transmitted to the ECM, and the forcible regeneration function starts. If the vehicle is driven continuously without performing the forcible regeneration function when the indicator lights are blinking, PM (Particulate Matter) accumulates and DTC P2002 is set. If the forcible regeneration function is activated when the amount of PM accumulation is too high, the temperature in the DPF catalytic converter rises beyond normal operating conditions, (it may reach 800 °C (1472 °F) or higher), and the DPF catalytic converter may melt down. Therefore, if the forcible regeneration function is activated with DTC P2002 set, the differential pressure when the engine is running at near the maximum no-load speed (3550 rpm) must be checked. If the pressure exceeds the threshold, the DPF catalytic converter must be cleaned.

A160134E05
3.292,2.948 3.958,2.625 false 5.573,1.625 4.781,0.958 false 0.896,3.385 1.042,3.563 0.146,0.177 10 false 0 0.823,3.063 1.031,3.24 0.208,0.177 10 false 10 0.823,2.698 1.031,2.875 0.208,0.177 10 false 20 0.823,2.365 1.031,2.542 0.208,0.177 10 false 30 0.833,2.031 1.042,2.208 0.208,0.177 10 false 40 0.833,1.698 1.042,1.875 0.208,0.177 10 false 50 0.844,1.365 1.052,1.542 0.208,0.177 10 false 60 1.01,3.51 1.156,3.688 0.146,0.177 10 false 0 1.99,3.531 2.198,3.708 0.208,0.177 10 false 50 2.99,3.521 3.271,3.698 0.281,0.177 10 false 100 4.01,3.531 4.292,3.708 0.281,0.177 10 false 150 5.042,3.521 5.323,3.698 0.281,0.177 10 false 200 6.094,3.521 6.375,3.698 0.281,0.177 10 false 250 0.167,1.104 1.885,1.281 1.719,0.177 10 false Differential Pressure (kPa) 5.917,3.823 6.74,4 0.823,0.177 10 false MAF (gm/s) 4.052,2.521 6.208,2.698 2.156,0.177 10 false Differential Pressure Limit Value 4.104,0.844 4.823,1.021 0.719,0.177 10 false Threshold

Engine Speed Standard Differential Pressure MAF
3500 to 3600 rpm 15 kPa or less 100 to 110 gm/s

CAUTION / NOTICE / HINT

NOTICE:
·

After replacing the ECM, the new ECM needs registration (Click here Engine / Hybrid System>N04C-UH (ENGINE CONTROL)>ECD SYSTEM>REGISTRATION) and initialization (Click here Engine / Hybrid System>N04C-UH (ENGINE CONTROL)>ECD SYSTEM>INITIALIZATION).

·

After replacing the supply pump, the ECM needs initialization (Click here Engine / Hybrid System>N04C-UH (ENGINE CONTROL)>ECD SYSTEM>INITIALIZATION).

·

After replacing the injector, the ECM needs registration (Click here Engine / Hybrid System>N04C-UH (ENGINE CONTROL)>ECD SYSTEM>REGISTRATION).



PROCEDURE

1.PERFORM ENGINE RPM ACCELERATION
a.

Warm up the engine.


b.

Disconnect the negative battery terminal and wait for at least 1 minute.


c.

Reconnect the negative battery terminal.


d.

Initialize the learning value of the supply pump (Click here Engine / Hybrid System>N04C-UH (ENGINE CONTROL)>ECD SYSTEM>INITIALIZATION).

HINT:

Perform initialization with the engine warmed up (engine coolant temperature is 60°C (140°F) or more and fuel temperature is 20°C (68°F) or more).



e.

Initialize the learning value of the diesel throttle body (Click here Engine / Hybrid System>N04C-UH (ENGINE CONTROL)>ECD SYSTEM>INITIALIZATION).


f.

Accelerate the engine speed to the maximum rpm with no load 20 times.


g.

Check the volume of black smoke in the exhaust gas.

HINT:
·

If DTC P2002 is stored, the engine speed cannot be raised to the high-speed range because the engine output limiting control is performed.

·

If DTC P2002 is stored, be sure to clear the DTCs.




Result:
Result Proceed to
Black smoke remains in the exhaust gas A
Black smoke is not present B



A

2.INSPECT AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY

B

8.CLEAR DTC
2.INSPECT AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY
a.

Inspect the air cleaner filter element sub-assembly.


Result:
Proceed to
OK
NG



OK

3.CHECK INTAKE SYSTEM

NG

REPAIR OR CLEAN AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY

3.CHECK INTAKE SYSTEM
a.

Check for air leak from the intake system and check that the intake system is installed properly.


Result:
Proceed to
OK
NG



OK

4.INSPECT FUEL FILTER ASSEMBLY

NG

REPAIR OR REPLACE MALFUNCTIONING PARTS, COMPONENT AND AREA

4.INSPECT FUEL FILTER ASSEMBLY
a.

Inspect the fuel filter assembly.


Result:
Proceed to
OK
NG



OK

5.READ VALUE USING INTELLIGENT TESTER (FUEL PRESS)

NG

REPLACE FUEL FILTER ASSEMBLY

5.READ VALUE USING INTELLIGENT TESTER (FUEL PRESS)
a.

Connect the intelligent tester to the DLC3.


b.

Start the engine.


c.

Turn the tester on.


d.

Enter the following menus: Powertrain / Engine and ECT / Data List / Fuel Press.


e.

Check that the internal fuel pressure of the common rail is within the specification below.

Standard:
Engine Speed Fuel Press
Idling Approximately 25000 to 35000 kPa



Result:
Proceed to
OK
NG



OK

6.CHECK FOR ENGINE OIL LEAK

NG

REPAIR OR REPLACE MALFUNCTIONING PARTS, COMPONENT AND AREA

6.CHECK FOR ENGINE OIL LEAK
a.

Check that the intake system pipes and hoses are not excessively contaminated with oil.


Result:
Proceed to
OK
NG



OK

7.CHECK CONNECTION OF VACUUM HOSE (DIFFERENTIAL PRESSURE SENSOR - CATALYTIC CONVERTER)

NG

REPAIR OR REPLACE MALFUNCTIONING PARTS, COMPONENT AND AREA

7.CHECK CONNECTION OF VACUUM HOSE (DIFFERENTIAL PRESSURE SENSOR - CATALYTIC CONVERTER)
a.

Check if the vacuum hose routing between the differential pressure sensor and the center exhaust pipe assembly (catalytic converter) is correct.


b.

Check that there is no exhaust gas leak between the differential pressure sensor and the center exhaust pipe assembly (catalytic converter).


Result:
Proceed to
OK
NG



OK

8.CLEAR DTC

NG

REPAIR OR REPLACE MALFUNCTIONING PARTS, COMPONENT AND AREA

8.CLEAR DTC
a.

Warm up the engine.


b.

Disconnect the negative battery terminal and wait for at least 1 minute.


c.

Reconnect the negative battery terminal.


d.

Initialize the learning value of the supply pump (Click here Engine / Hybrid System>N04C-UH (ENGINE CONTROL)>ECD SYSTEM>INITIALIZATION).

HINT:

Perform initialization with the engine warmed up (engine coolant temperature is 60°C (140°F) or more and fuel temperature is 20°C (68°F) or more).



e.

Initialize the learning value of the diesel throttle body (Click here Engine / Hybrid System>N04C-UH (ENGINE CONTROL)>ECD SYSTEM>INITIALIZATION).


Result:
Proceed to
NEXT



NEXT

9.READ VALUE USING INTELLIGENT TESTER (DIFFERENTIAL PRESSURE)
9.READ VALUE USING INTELLIGENT TESTER (DIFFERENTIAL PRESSURE)
a.

Allow the engine to idle for at least 5 minutes.


b.

Connect the intelligent tester to the DLC3.


c.

Turn the tester on.


d.

Enter the following menus: Powertrain / Engine and ECT / Data List / DPF Differential Pressure.

HINT:
·

If the exhaust gas temperature is high, the differential pressure cannot be measured correctly.

·

If the differential pressure is outside the normal range, the center exhaust pipe assembly (catalytic converter) may have deteriorated or the center exhaust pipe assembly (catalytic converter) may be clogged with PM.

·

Fully depress the accelerator pedal and when the engine speed becomes stable, promptly read the differential pressure.




Result:
Engine Speed (no engine load) Differential Pressure Proceed to
3500 to 3600 rpm (Exhaust gas temperature (up stream) is 200°C or less) 25 kPa or more A
Less than 25 kPa B



A

10.READ VALUE USING INTELLIGENT TESTER (EXHAUST TEMPERATURE DURING FORCIBLE REGENERATION FUNCTION)

B

16.CLEAN EXHAUST SYSTEM
10.READ VALUE USING INTELLIGENT TESTER (EXHAUST TEMPERATURE DURING FORCIBLE REGENERATION FUNCTION)
a.

Connect the intelligent tester to the DLC3.


b.

Start the engine.


c.

Turn the tester on.


d.

Perform the forcible regeneration function (Click here Engine / Hybrid System>N04C-UH (ENGINE CONTROL)>ECD SYSTEM>DPF Switch and Buzzer Circuit).


e.

Enter the following menus: Powertrain / Engine and ECT / Data List.


f.

Enter the following menus, and read the value every minute during the forcible regeneration function.

·

Exhaust Temperature B1S1

·

Exhaust Temperature B1S2

·

Engine Speed


Result:
Result Proceed to
Less than 800 °C (1472 °F) A
800 °C (1472 °F) or more B


NOTICE:

If Initial Exhaust Temp (OUT) exceeds 800°C (1472°F), cease the forcible regeneration function immediately.




A

11.READ VALUE USING INTELLIGENT TESTER (ENGINE SPEED DURING FORCIBLE REGENERATION FUNCTION)

B

16.CLEAN EXHAUST SYSTEM
11.READ VALUE USING INTELLIGENT TESTER (ENGINE SPEED DURING FORCIBLE REGENERATION FUNCTION)
a.

Read the engine speed during the forcible regeneration function.

Standard:
Condition Engine Speed
During forcible regeneration function 1200 rpm or more



Result:
Proceed to
OK
NG



OK

12.READ VALUE USING INTELLIGENT TESTER (EXHAUST TEMPERATURE DURING FORCIBLE REGENERATION FUNCTION)

NG

18.READ VALUE USING INTELLIGENT TESTER (INJECTION VOLUME)
12.READ VALUE USING INTELLIGENT TESTER (EXHAUST TEMPERATURE DURING FORCIBLE REGENERATION FUNCTION)
a.

Read the exhaust gas temperature after at least 5 minutes have elapsed since the forcible regeneration function was started.

Standard:
Condition Exhaust Temperature B1S1
During forcible regeneration function 220°C (428°F) or more



Result:
Proceed to
OK
NG



OK

13.READ VALUE USING INTELLIGENT TESTER (EXHAUST TEMPERATURE DURING FORCIBLE REGENERATION FUNCTION)

NG

20.READ VALUE USING INTELLIGENT TESTER (EXHAUST TEMPERATURE DURING FORCIBLE REGENERATION FUNCTION)
13.READ VALUE USING INTELLIGENT TESTER (EXHAUST TEMPERATURE DURING FORCIBLE REGENERATION FUNCTION)
a.

Read the exhaust gas temperature just before the forcible regeneration function is completed.

Standard:
Condition Exhaust Temperature B1S1
During forcible regeneration function 480°C (896°F) or more



Result:
Proceed to
OK
NG



OK

14.READ VALUE USING INTELLIGENT TESTER (DIFFERENTIAL PRESSURE)

NG

25.READ VALUE USING INTELLIGENT TESTER (INJECTION VOLUME DURING FORCIBLE REGENERATION FUNCTION)
14.READ VALUE USING INTELLIGENT TESTER (DIFFERENTIAL PRESSURE)
a.

After the forcible regeneration is completed, allow the engine to idle for at least 5 minutes.


b.

Connect the intelligent tester to the DLC3.


c.

Turn the ignition switch to ON.


d.

Turn the tester on.


e.

Enter the following menus: Powertrain / Engine and ECT / Data List / DPF Differential Pressure.


f.

Check the differential pressure when the exhaust gas temperature sensor indicates 200°C or less.

HINT:
·

If the exhaust gas temperature is high, the differential pressure cannot be measured correctly.

·

If the differential pressure is outside the normal range, the center exhaust pipe assembly (catalytic converter) may have deteriorated or the center exhaust pipe assembly (catalytic converter) may be clogged with PM.

·

Fully depress the accelerator pedal and when the engine speed becomes stable, promptly read the differential pressure.



Standard:
Engine Speed Differential Pressure
3500 to 3600 rpm (no engine load) Less than 15 kPa



Result:
Proceed to
OK
NG



OK

15.CHECK ENGINE OIL LEVEL

NG

REPLACE CENTER EXHAUST PIPE ASSEMBLY

15.CHECK ENGINE OIL LEVEL
a.

Check the engine oil level.


Result:
Proceed to
OK
NG



OK

END

NG

REPLACE ENGINE OIL

16.CLEAN EXHAUST SYSTEM
a.

Remove the catalytic converter and the monolithic converter.


b.

Blow air to clean the catalytic converter, or soak it in water and wash off the soot.

NOTICE:
·

Make sure to clean both oxidation catalyst and DPF catalyst.

·

After installing the catalytic converter, increase idling speed until steam is no longer emitted.




c.

Reinstall the catalytic converter and the monolithic converter.


Result:
Proceed to
NEXT



NEXT

17.READ VALUE USING INTELLIGENT TESTER (DIFFERENTIAL PRESSURE)
17.READ VALUE USING INTELLIGENT TESTER (DIFFERENTIAL PRESSURE)
a.

Allow the engine to idle for at least 5 minutes.


b.

Connect the intelligent tester to the DLC3.


c.

Turn the tester on.


d.

Enter the following menus: Powertrain / Engine and ECT / Data List / DPF Differential Pressure.


e.

Read the value.

HINT:
·

If the exhaust gas temperature is high, the differential pressure cannot be measured correctly.

·

If the differential pressure is outside the normal range, the center exhaust pipe assembly (catalytic converter) may have deteriorated or the center exhaust pipe assembly (catalytic converter) may be clogged with PM.

·

Fully depress the accelerator pedal and when the engine speed becomes stable, promptly read the differential pressure.




Result:
Engine Speed (no engine load) Differential Pressure Proceed to
3500 to 3600 rpm (Exhaust gas temperature (up stream) is 200°C or less) 25 kPa or more A
Less than 25 kPa B



A

REPLACE CENTER EXHAUST PIPE ASSEMBLY

B

10.READ VALUE USING INTELLIGENT TESTER (EXHAUST TEMPERATURE DURING FORCIBLE REGENERATION FUNCTION)
18.READ VALUE USING INTELLIGENT TESTER (INJECTION VOLUME)
a.

Cease the forcible regeneration function.


b.

Connect the intelligent tester to the DLC3.


c.

Start the engine.


d.

Turn the tester on.


e.

Enter the following menus: Powertrain / Engine and ECT / Data List / Injection Volume.


f.

Read the value.

Standard:
Condition Injection Volume
Idling 5.0 to 16.0 mm3/st



Result:
Result Proceed to
NG A
OK B



A

19.REPLACE INJECTOR ASSEMBLY

B

21.ADJUST EXHAUST RETARDER ASSEMBLY
19.REPLACE INJECTOR ASSEMBLY
a.

Replace the injector assembly (Click here Engine / Hybrid System>N04C-UH (FUEL)>FUEL INJECTOR>REMOVAL).


Result:
Proceed to
NEXT



NEXT

20.READ VALUE USING INTELLIGENT TESTER (EXHAUST TEMPERATURE DURING FORCIBLE REGENERATION FUNCTION)
a.

Read the exhaust gas temperature during the forcible regeneration function.

Standard:
Condition Exhaust Temperature B1S2
During forcible regeneration function 220°C (428°F) or more



Result:
Proceed to
OK
NG



OK

REPLACE EXHAUST TEMPERATURE SENSOR (DOWN STREAM)

NG

22.READ VALUE USING INTELLIGENT TESTER (INJECTION VOLUME DURING FORCIBLE REGENERATION FUNCTION)
21.ADJUST EXHAUST RETARDER ASSEMBLY
a.

Adjust the exhaust retarder gap (widen the gap).

A428644E01
1.667,2.094 1.979,0.927 1.979,0.927 1.823,0.927 true 2.99,1.052 3.083,1.979 true 1.125,0.281 2.958,0.615 1.833,0.333 10 false Cross section of valve (viewed from the lever side) 1.167,0.823 1.844,1 0.677,0.177 10 false Clearance 2.719,1.99 3.427,2.188 0.708,0.198 10 false Clearance 5.219,1.208 5.375,1.406 0.156,0.198 10 true A 5.438,2.115 5.594,2.313 0.156,0.198 10 false B

i.

While holding bolt A, loosen nut B.


ii.

Using SST, turn adjusting bolt A to adjust the valve body clearance.

Standard Clearance:

0.2 to 0.3 mm (0.0079 to 0.0118 in.)



iii.

While holding bolt A, tighten nut B.

Torque:

7.4 N*m (75 kgf*cm 65 in*lbf)




Result:
Proceed to
NEXT



NEXT

22.READ VALUE USING INTELLIGENT TESTER (INJECTION VOLUME DURING FORCIBLE REGENERATION FUNCTION)
a.

Read the injection volume during the forcible regeneration function.

Standard:
Condition Injection Volume
During forcible regeneration function 18 to 24 mm3/st



Result:
Proceed to
OK
NG



OK

23.CHECK FOR EXHAUST GAS LEAK

NG

24.ADJUST EXHAUST RETARDER ASSEMBLY
23.CHECK FOR EXHAUST GAS LEAK
a.

Check the exhaust gas leak.


Result:
Proceed to
NEXT



NEXT

24.ADJUST EXHAUST RETARDER ASSEMBLY
a.

Adjust the exhaust retarder gap (widen the gap).

A428644E01
1.667,2.094 1.979,0.927 1.979,0.927 1.823,0.927 true 2.99,1.052 3.083,1.979 true 1.125,0.281 2.958,0.615 1.833,0.333 10 false Cross section of valve (viewed from the lever side) 1.167,0.823 1.844,1 0.677,0.177 10 false Clearance 2.719,1.99 3.427,2.188 0.708,0.198 10 false Clearance 5.219,1.208 5.375,1.406 0.156,0.198 10 true A 5.438,2.115 5.594,2.313 0.156,0.198 10 false B

i.

While holding bolt A, loosen nut B.


ii.

Using SST, turn adjusting bolt A to adjust the valve body clearance.

Standard Clearance:

0.2 to 0.3 mm (0.0079 to 0.0118 in.)



iii.

While holding bolt A, tighten nut B.

Torque:

7.4 N*m (75 kgf*cm 65 in*lbf)




Result:
Proceed to
NEXT



NEXT

25.READ VALUE USING INTELLIGENT TESTER (INJECTION VOLUME DURING FORCIBLE REGENERATION FUNCTION)
a.

Read the injection volume during the forcible regeneration function.

Standard:
Condition Injection Volume
During forcible regeneration function 18 to 24 mm3/st



Result:
Proceed to
OK
NG



OK

26.READ VALUE USING INTELLIGENT TESTER (FUEL PRESS)

NG

28.ADJUST EXHAUST RETARDER ASSEMBLY
26.READ VALUE USING INTELLIGENT TESTER (FUEL PRESS)
a.

Cease the forcible regeneration function.


b.

Connect the intelligent tester to the DLC3.


c.

Start the engine.


d.

Turn the tester on.


e.

Enter the following menu items: Powertrain / Engine and ECT / Data List / Fuel Press.


f.

Check that the internal fuel pressure of the common rail is within the specification below.

Standard:
Engine Speed Fuel Pressure
Idling Approximately 25000 to 35000 kPa



Result:
Proceed to
OK
NG



OK

27.INSPECT INJECTION OR SUPPLY PUMP ASSEMBLY

NG

REPAIR OR REPLACE FUEL SYSTEM

27.INSPECT INJECTION OR SUPPLY PUMP ASSEMBLY
a.

Inspect the injection or supply pump assembly (Click here Engine / Hybrid System>N04C-UH (FUEL)>FUEL SUPPLY PUMP>INSPECTION).


Result:
Result Proceed to
NG A
OK B



A

REPLACE INJECTION OR SUPPLY PUMP ASSEMBLY

B

16.CLEAN EXHAUST SYSTEM
28.ADJUST EXHAUST RETARDER ASSEMBLY
a.

Adjust the exhaust retarder gap (widen the gap).

A428644E01
1.667,2.094 1.979,0.927 1.979,0.927 1.823,0.927 true 2.99,1.052 3.083,1.979 true 1.125,0.281 2.958,0.615 1.833,0.333 10 false Cross section of valve (viewed from the lever side) 1.167,0.823 1.844,1 0.677,0.177 10 false Clearance 2.719,1.99 3.427,2.188 0.708,0.198 10 false Clearance 5.219,1.208 5.375,1.406 0.156,0.198 10 true A 5.438,2.115 5.594,2.313 0.156,0.198 10 false B

i.

While holding bolt A, loosen nut B.


ii.

Using SST, turn adjusting bolt A to adjust the valve body clearance.

Standard Clearance:

0.2 to 0.3 mm (0.0079 to 0.0118 in.)



iii.

While holding bolt A, tighten nut B.

Torque:

7.4 N*m (75 kgf*cm 65 in*lbf)




Result:
Proceed to
NEXT



NEXT