The tank heater prevents urea solution in the tank freezing.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate | Memory |
|---|---|---|---|---|---|---|
| P20BE92 | Reductant Heater "B" Control Circuit Performance Performance or Incorrect Operation | Diagnosis Condition:
·
The tank heater is activated. ·
The urea tank is frozen. Malfunction Status: ·
The urea solution temperature change is less than specified value. Malfunction Duration: ·
- |
·
Open or short in tank heater (urea pump) circuit ·
Tank heater (urea pump) ·
DCU (emission control ECU assembly) |
Class A | AdBlue consumption warning light:
Comes on |
DTC stored |
Heater malfunction of urea pump is detected. (Even if heated, urea solution temperature does not increase.)
After having restored to the normal conditions.
Refer to DTC P20BD14.
Click hereEngine / Hybrid System>N04C-WA (EMISSION CONTROL)>UREA SELECTIVE CATALYTIC REDUCTION SYSTEM>P20BD14
Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.
Check the connector connection and contact pressure of the tank heater (urea pump) connector.
The connector is connected securely and there are no contact pressure problems.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check the connector connection and contact pressure of the DCU (emission control ECU assembly) connector.
The connector is connected securely and there are no contact pressure problems.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component without harness connected
(Tank Heater (Urea Pump)) |
Disconnect the tank heater (urea pump) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 9 (HTT) - 11 (EHTT) | 25°C | 1.36 to 1.52 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Signal Check Harness No. 2 Lead Connector |
Connect the tank heater (urea pump) connector.
Connect the signal check harness No. 2 to the DCU (emission control ECU assembly) vehicle side harness. (Do not connect the harness to the DCU (emission control ECU assembly).)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E-2 (HTT) - E-21 (EHTT) | 25°C | 1.36 to 1.52 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Securely connect the DCU (emission control ECU assembly) connector.
Repair parts as necessary.
| Proceed to |
|---|
| NEXT |
NEXT
Securely connect the tank heater (urea pump) connector.
Repair parts as necessary.
| Proceed to |
|---|
| NEXT |
NEXT