Home › Engine / Hybrid System › N04C-WA (EMISSION CONTROL) › UREA SELECTIVE CATALYTIC REDUCTION SYSTEM › from 2019.08
RM2850E _51 Engine / Hybrid System _082614 N04C-WA EMISSION CONTROL _0400651 UREA SELECTIVE CATALYTIC REDUCTION SYSTEM C

N04C-WA EMISSION CONTROL  UREA SELECTIVE CATALYTIC REDUCTION SYSTEM  P20BE92  Reductant Heater "B" Control Circuit Performance Performance or Incorrect Operation  


DESCRIPTION

The tank heater prevents urea solution in the tank freezing.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate Memory
P20BE92 Reductant Heater "B" Control Circuit Performance Performance or Incorrect Operation Diagnosis Condition:
·

The tank heater is activated.

·

The urea tank is frozen.


Malfunction Status:
·

The urea solution temperature change is less than specified value.


Malfunction Duration:
·

-


·

Open or short in tank heater (urea pump) circuit

·

Tank heater (urea pump)

·

DCU (emission control ECU assembly)


Class A AdBlue consumption warning light:
Comes on
DTC stored

MONITOR DESCRIPTION

Description of malfunction

Heater malfunction of urea pump is detected. (Even if heated, urea solution temperature does not increase.)


Reset condition

After having restored to the normal conditions.


CAUTION / NOTICE / HINT

HINT:

Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.


PROCEDURE

1.CHECK CONNECTOR CONNECTION CONDITION (TANK HEATER (UREA PUMP))
a.

Check the connector connection and contact pressure of the tank heater (urea pump) connector.

OK:

The connector is connected securely and there are no contact pressure problems.



Result:
Proceed to
OK
NG



OK

2.CHECK CONNECTOR CONNECTION CONDITION (DCU (EMISSION CONTROL ECU ASSEMBLY))

NG

6.CONNECT SECURELY
2.CHECK CONNECTOR CONNECTION CONDITION (DCU (EMISSION CONTROL ECU ASSEMBLY))
a.

Check the connector connection and contact pressure of the DCU (emission control ECU assembly) connector.

OK:

The connector is connected securely and there are no contact pressure problems.



Result:
Proceed to
OK
NG



OK

3.INSPECT TANK HEATER (UREA PUMP)

NG

5.CONNECT SECURELY
3.INSPECT TANK HEATER (UREA PUMP)
a.
A355506C09
0.479,1.615 0.896,1.198 false 1.906,1.625 1.458,1.188 false 0.135,0.135 0.448,0.333 0.313,0.198 10 false *a 0.24,1.635 0.615,1.802 0.375,0.167 10 false HTT 1.927,1.625 2.302,1.792 0.375,0.167 10 false EHTT
*a Component without harness connected
(Tank Heater (Urea Pump))


Disconnect the tank heater (urea pump) connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
9 (HTT) - 11 (EHTT) 25°C 1.36 to 1.52 Ω



Result:
Proceed to
OK
NG



OK

4.CHECK HARNESS AND CONNECTOR (TANK HEATER (UREA PUMP) - DCU (EMISSION CONTROL ECU ASSEMBLY))

NG

4.CHECK HARNESS AND CONNECTOR (TANK HEATER (UREA PUMP) - DCU (EMISSION CONTROL ECU ASSEMBLY))
a.
A405886C01
1.51,0.125 1.885,0.406 0.375,0.281 0.083,0.115 0.396,0.313 0.313,0.198 10 false *a 1.667,0.208 1.979,0.406 0.313,0.198 10 false E
*a Signal Check Harness No. 2 Lead Connector


Connect the tank heater (urea pump) connector.


b.

Connect the signal check harness No. 2 to the DCU (emission control ECU assembly) vehicle side harness. (Do not connect the harness to the DCU (emission control ECU assembly).)


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
E-2 (HTT) - E-21 (EHTT) 25°C 1.36 to 1.52 Ω



Result:
Proceed to
OK
NG



OK

REPLACE DCU (EMISSION CONTROL ECU ASSEMBLY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.CONNECT SECURELY
a.

Securely connect the DCU (emission control ECU assembly) connector.

HINT:

Repair parts as necessary.



Result:
Proceed to
NEXT



NEXT

3.INSPECT TANK HEATER (UREA PUMP)
6.CONNECT SECURELY
a.

Securely connect the tank heater (urea pump) connector.

HINT:

Repair parts as necessary.



Result:
Proceed to
NEXT



NEXT

2.CHECK CONNECTOR CONNECTION CONDITION (DCU (EMISSION CONTROL ECU ASSEMBLY))