Home › Engine / Hybrid System › N04C-WA (EMISSION CONTROL) › UREA TUBE › from 2019.08
RM2850E _51 Engine / Hybrid System _082614 N04C-WA EMISSION CONTROL _0403725 UREA TUBE A

N04C-WA EMISSION CONTROL  UREA TUBE  INSTALLATION  


PROCEDURE

Hide 77840A 1.INSTALL UREA TUBE WITH HEATER ASSEMBLY (FRONT)

a.
A450175

Attach the 2 clamps.


b.
A450174

Install the No. 1 fuel tank heat insulator with the 3 bolts.

Torque:
14 N*m (143 kgf*cm, 10 ft.*lbf)


c.

Attach the 4 clamps.


d.
A450173

Attach the clamp.


e.
A450176

Attach the 8 clamps and install the urea tube with heater assembly.


f.

Connect the urea tube with heater assembly to the urea injector assembly.

HINT:

If there is any solidified urea solution (white solids) on the connection areas of the urea tube with heater assembly and urea injector assembly, clean the solids off with water. Otherwise, they may prevent the O-ring from sealing properly.


i.

Wash the connection area of the urea tube with heater connector with water to remove all solidified urea solution (white solids).


ii.

Wipe off the connection area of the urea injector assembly with water to remove all solidified urea solution (white solids).


iii.
A447461C01
0,0 0,0 false
V100135

Push
V100136

Push Down


Align the axis of the connector with the axis of the urea injector assembly. Push the urea tube with heater connector into the urea injector assembly until the urea tube with heater connector makes a "click" sound.


iv.

After connecting the urea injector assembly and the urea tube with heater connector, check that the urea injector assembly and urea tube with heater connector are securely connected by trying to pull them apart.


v.

Attach the lock claws to the urea tube connector by pushing down on the cover.



Hide 77840A 2.INSTALL UREA TUBE WITH HEATER ASSEMBLY (REAR)

a.
A450169

Attach the 6 clamps and install the urea tube with heater assembly.


b.
A450167

Attach the 3 clamps.


c.

Connect the connector.


d.

Install the urea tube with heater assembly to the urea pump.

HINT:

If there is any solidified urea solution (white solids) on the connection areas of the urea tube with heater assembly and urea pump, clean the solids off with water. Otherwise, they may prevent the O-ring from sealing properly.


i.

Wash the connection area of the urea tube connector with water to remove all solidified urea solution (white solids).


ii.

Wipe off the connection area of the urea pump with water to remove all solidified urea solution (white solids).


iii.
A451144C01
0,0 0,0 false
V100135

Push
V100136

Push Down


Align the axis of the urea tube connector with the axis of the urea pump. Push the urea tube connector into the urea pump until the urea tube connector makes a "click" sound.


iv.

After connecting the urea pump and the urea tube connector, check that the urea pump and urea tube connector are securely connected by trying to pull them apart.


v.

Attach the lock claws to the urea tube connector by pushing down on the cover.



e.

Connect the urea tube with heater assembly.

HINT:

If there is any solidified urea solution (white solids) on the connection areas of the urea tube with heater assembly and urea pump, clean the solids off with water. Otherwise, they may prevent the O-ring from sealing properly.


i.

Wash the connection area of the urea tube connector with water to remove all solidified urea solution (white solids).


ii.
A451143C01
0,0 0,0 false
V100135

Push
V100136

Push Down


Align the axis of the urea tube connector with the axis of the pipe. Push the urea tube connector into the pipe until the urea tube connector makes a "click" sound.


iii.

After connecting the urea tube connector, check that the urea tube connector are securely connected by trying to pull them apart.


iv.

Attach the lock claws to the urea tube connector by pushing down on the cover.



Hide 77851A 3.INSTALL UREA TANK PROTECTOR

Hide 18040A 4.INSTALL NO. 2 EXHAUST PIPE CONVERTER ASSEMBLY

Hide 77100 5.INSTALL FUEL TANK ASSEMBLY