77840A
1.INSTALL UREA TUBE WITH HEATER ASSEMBLY (FRONT)
Attach the 2 clamps.
Install the No. 1 fuel tank heat insulator with the 3 bolts.
Attach the 4 clamps.
Attach the clamp.
Attach the 8 clamps and install the urea tube with heater assembly.
Connect the urea tube with heater assembly to the urea injector assembly.
If there is any solidified urea solution (white solids) on the connection areas of the urea tube with heater assembly and urea injector assembly, clean the solids off with water. Otherwise, they may prevent the O-ring from sealing properly.
Wash the connection area of the urea tube with heater connector with water to remove all solidified urea solution (white solids).
Wipe off the connection area of the urea injector assembly with water to remove all solidified urea solution (white solids).
|
Push |
|
Push Down |
Align the axis of the connector with the axis of the urea injector assembly. Push the urea tube with heater connector into the urea injector assembly until the urea tube with heater connector makes a "click" sound.
After connecting the urea injector assembly and the urea tube with heater connector, check that the urea injector assembly and urea tube with heater connector are securely connected by trying to pull them apart.
Attach the lock claws to the urea tube connector by pushing down on the cover.
77840A
2.INSTALL UREA TUBE WITH HEATER ASSEMBLY (REAR)
Attach the 6 clamps and install the urea tube with heater assembly.
Attach the 3 clamps.
Connect the connector.
Install the urea tube with heater assembly to the urea pump.
If there is any solidified urea solution (white solids) on the connection areas of the urea tube with heater assembly and urea pump, clean the solids off with water. Otherwise, they may prevent the O-ring from sealing properly.
Wash the connection area of the urea tube connector with water to remove all solidified urea solution (white solids).
Wipe off the connection area of the urea pump with water to remove all solidified urea solution (white solids).
|
Push |
|
Push Down |
Align the axis of the urea tube connector with the axis of the urea pump. Push the urea tube connector into the urea pump until the urea tube connector makes a "click" sound.
After connecting the urea pump and the urea tube connector, check that the urea pump and urea tube connector are securely connected by trying to pull them apart.
Attach the lock claws to the urea tube connector by pushing down on the cover.
Connect the urea tube with heater assembly.
If there is any solidified urea solution (white solids) on the connection areas of the urea tube with heater assembly and urea pump, clean the solids off with water. Otherwise, they may prevent the O-ring from sealing properly.
Wash the connection area of the urea tube connector with water to remove all solidified urea solution (white solids).
|
Push |
|
Push Down |
Align the axis of the urea tube connector with the axis of the pipe. Push the urea tube connector into the pipe until the urea tube connector makes a "click" sound.
After connecting the urea tube connector, check that the urea tube connector are securely connected by trying to pull them apart.
Attach the lock claws to the urea tube connector by pushing down on the cover.
77851A
3.INSTALL UREA TANK PROTECTOR
18040A
4.INSTALL NO. 2 EXHAUST PIPE CONVERTER ASSEMBLY
77100
5.INSTALL FUEL TANK ASSEMBLY