The intake air temperature sensor, mounted on the mass air flow meter sub-assembly, monitors the intake air temperature. The intake air temperature sensor has a built-in thermistor with a resistance that varies according to the temperature of the intake air. When the intake air temperature is low, the resistance of the thermistor increases. When the temperature is high, the resistance drops. These variations in resistance are transmitted to the ECM as voltage changes (see Fig. 1).
The intake air temperature sensor is powered by a 5 V supply from the THA terminal of the ECM, via resistor R.
Resistor R and the intake air temperature sensor are connected in series. When the resistance value of the intake air temperature sensor changes, the voltage at terminal THA varies accordingly. Based on this signal, the ECM increases the fuel injection volume when the engine is cold to improve driveability.
When DTC P0110, P0112 or P0113 is stored, the ECM enters fail-safe mode. During fail-safe mode, the intake air temperature is estimated to be 20°C (68°F) by the ECM. Fail-safe mode continues until a pass condition is detected.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P0110 | Open or short in intake air temperature sensor circuit for 0.5 seconds
(1 trip detection logic) |
·
Open or short in intake air temperature sensor circuit ·
Intake air temperature sensor (built into mass air flow meter sub-assembly) ·
ECM |
| P0112 | Short in intake air temperature sensor circuit for 0.5 seconds (1 trip detection logic) | ·
Short in intake air temperature sensor circuit ·
Intake air temperature sensor (built into mass air flow meter sub-assembly) ·
ECM |
| P0113 | Open in intake air temperature sensor circuit for 0.5 seconds (1 trip detection logic) | ·
Open in intake air temperature sensor circuit ·
Intake air temperature sensor (built into mass air flow meter sub-assembly) ·
ECM |
When any of these DTCs are output, check the intake air temperature using the intelligent tester. Enter the following menus: Powertrain / Engine / Data List / All Data / Intake Air.
| Temperature Displayed | Malfunction |
|---|---|
| -40°C (-40°F) | Open circuit |
| 140°C (284°F) | Short circuit |
Read freeze frame data using the intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air-fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG).
Turn the tester on.
Enter the following menus: Powertrain / Engine / Data List / All Data / Intake Air.
Read the value displayed on the tester.
Same as actual intake air temperature.
| Result | Proceed to |
|---|---|
| -40°C (-40°F) | A |
| 140°C (284°F) | B |
| Same as actual intake air temperature | C |
If there is an open circuit, the tester indicates -40°C (-40°F).
If there is a short circuit, the tester indicates 140°C (284°F).
A
B
C
Disconnect the mass air flow meter sub-assembly connector.
Connect terminals 1 (THA) and 2 (E2) of the mass air flow meter sub-assembly wire harness side connector.
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG).
Turn the tester on.
Enter the following menus: Powertrain / Engine / Data List / All Data / Intake Air.
Read the value displayed on the tester.
140°C (284°F)
OK
NG
Disconnect the mass air flow meter sub-assembly connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D1-71 (THA) - D3-1 (THA) | Always | Below 1 Ω |
| D1-74 (ETHA) - D3-2 (E2) | Always | Below 1 Ω |
OK
NG
Disconnect the mass air flow meter sub-assembly connector.
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG).
Turn the tester on.
Enter the following menus: Powertrain / Engine / Data List / All Data / Intake Air.
Read the value displayed on the tester.
-40°C (-40°F)
OK
NG
Disconnect the mass air flow meter sub-assembly connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D1-71 (THA) or D3-1 (THA) - Body ground | Always | 10 kΩ or higher |
OK
NG