To reduce hydrocarbon (HC) emissions, evaporated fuel from the fuel tank is routed through a canister to the intake air surge tank assembly for combustion in the cylinders.
The ECM changes the duty signals to the purge VSV so that the intake amount of hydrocarbon (HC) emissions is appropriate for the driving conditions (engine load, engine speed, vehicle speed, etc.) after the engine is warmed up.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P0443 | Terminal voltage of ECM output circuit does not correspond with drive signals from ECM to purge VSV
(1 trip detection logic) |
·
Open or short in purge VSV circuit ·
Purge VSV ·
ECM |
Read freeze frame data using the intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air-fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.
Connect the intelligent tester to the DLC3.
Remove the vacuum hose of the purge VSV from the charcoal canister.
Start the engine and turn the tester ON.
Enter the following menus: Powertrain / Engine / Active Test / Activate the VSV for Evap Control.
When the purge VSV is operated using the intelligent tester, check whether the disconnected hose applies suction to your finger.
| Tester Operation | Specified Condition |
|---|---|
| VSV is ON | Disconnected hose applies suction to finger |
| VSV is OFF | Disconnected hose applies no suction to finger |
OK
NG
Inspect the purge VSV (See page Engine / Hybrid System>2GR-FE EMISSION CONTROL>VACUUM SWITCHING VALVE>INSPECTION).
OK
NG
Disconnect the purge VSV connector.
Turn the engine switch on (IG).
Measure the voltage between the terminal of the wire harness side connector and body ground.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D50-2 - Body ground | Engine switch on (IG) | 11 to 14 V |
OK
NG
Disconnect the purge VSV connector.
Disconnect the ECM connector.
Measure the resistance between the wire harness side connectors.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D50-2 - D1-108 (PRG) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D50-2 or D1-108 (PRG) - Body ground | Always | 10 kΩ or higher |
OK
NG