In order to obtain a high purification rate of the carbon monoxide (CO), hydrocarbon (HC) and nitrogen oxide (NOx) components in the exhaust gas, a TWC (Three-Way Catalytic Converter) is used. For the most efficient use of the TWC, the air fuel ratio must be precisely controlled so that it is always close to the stoichiometric air fuel level. For the purpose of helping the ECM to deliver accurate air fuel ratio control, a heated oxygen sensor is used.
The heated oxygen sensor is located behind the TWC, and detects the oxygen concentration in the exhaust gas. Since the sensor is integrated with the heater that heats the sensing portion, it is possible to detect the oxygen concentration even when the intake air volume is low (the exhaust gas temperature is low).
When the air fuel ratio becomes lean, the oxygen concentration in the exhaust gas is high. The heated oxygen sensor informs the ECM that the post-TWC air fuel ratio is lean (low voltage, i.e. less than 0.45 V).
Conversely, when the air fuel ratio is richer than the stoichiometric air fuel level, the oxygen concentration in the exhaust gas is low. The heated oxygen sensor informs the ECM that the post-TWC air fuel ratio is rich (high voltage, i.e. more than 0.45 V). The heated oxygen sensor has the property of changing its output voltage drastically when the air fuel ratio is close to the stoichiometric level.
The ECM uses the supplementary information from the heated oxygen sensor to determine whether the air fuel ratio after the TWC is rich or lean, and adjusts the fuel injection duration accordingly. Thus, if the heated oxygen sensor is working improperly due to internal malfunctions, the ECM is unable to compensate for deviations in the primary air fuel ratio control.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P0136 | Abnormal voltage output:
During active air fuel ratio control, the following conditions (a) and (b) are met for a certain period of time (2 trip detection logic): (a) Heated oxygen sensor voltage does not increase to 0.69 V or higher. (b) Heated oxygen sensor voltage does not decrease to less than 0.21 V. |
·
Heated oxygen sensor (sensor 2) circuit ·
Heated oxygen sensor (sensor 2) ·
Air fuel ratio sensor (sensor 1) ·
Gas leak from exhaust system ·
Fuel injector ·
Fuel pressure ·
PCV valve and hose ·
Intake system |
| P0137 | Low voltage (open):
During active air fuel ratio control, the following conditions (a) and (b) are met for a certain period of time (2 trip detection logic): (a) Heated oxygen sensor voltage output is less than 0.21 V. (b) Target air fuel ratio is rich. |
·
Heated oxygen sensor (sensor 2) circuit ·
Heated oxygen sensor (sensor 2) ·
Air fuel ratio sensor (sensor 1) ·
Gas leak from exhaust system |
| P0138 | High voltage (short):
During active air fuel ratio control, the following conditions (a) and (b) are met for a certain period of time (2 trip detection logic): (a) Heated oxygen sensor voltage output is higher than 0.69 V. (b) Target air fuel ratio is lean. |
·
Heated oxygen sensor (sensor 2) circuit ·
Heated oxygen sensor (sensor 2) ·
Air fuel ratio sensor (sensor 1) ·
ECM |
Active Air Fuel Ratio Control
The ECM usually performs air fuel ratio feedback control so that the air fuel ratio sensor output indicates a near stoichiometric air fuel level. This vehicle includes active air fuel ratio control in addition to regular air fuel ratio control. The ECM performs active air fuel ratio control to detect any deterioration in the Three-Way Catalytic Converter (TWC) and heated oxygen sensor malfunctions (refer to the diagram below).
Active air fuel ratio control is performed for approximately 15 to 20 seconds while driving with a warm engine. During active air fuel ratio control, the air fuel ratio is forcibly regulated to become lean or rich by the ECM. If the ECM detects a malfunction, a DTC is stored.
Abnormal Voltage Output of Heated Oxygen Sensor (DTC P0136)
While the ECM is performing active air fuel ratio control, the air fuel ratio is forcibly regulated to become rich or lean. If the sensor is not functioning properly, the voltage output variation is small. For example, when the heated oxygen sensor voltage does not decrease to less than 0.21 V and does not increase to higher than 0.69 V during active air fuel ratio control, the ECM determines that the sensor voltage output is abnormal and stores DTC P0136.
Open or Short in Heated Oxygen Sensor Circuit (DTC P0137 or P0138)
During active air fuel ratio control, the ECM calculates the Oxygen Storage Capacity (OSC)* of the Three-Way Catalytic Converter (TWC) by forcibly regulating the air fuel ratio to become rich or lean. If the heated oxygen sensor has an open or short circuit, or the voltage output of the sensor noticeably decreases, the OSC indicated an extraordinarily high value. Even if the ECM attempts to continue regulating the air fuel ratio to become rich or lean, the heated oxygen sensor output does not change.
While performing active air fuel ratio control, when the target air fuel ratio is rich and the heated oxygen sensor voltage output is less than 0.21 V (lean), the ECM interprets this as an abnormally low sensor output voltage and stores DTC P0137. When the target air fuel ratio is lean and the voltage output is higher than 0.69 V (rich) during active air fuel ratio control, the ECM determines that the sensor voltage output is abnormally high and stores DTC P0138.
*: The TWC has the capability to store oxygen. The OSC and the emissions purification capacity of the TWC are mutually related. The ECM determines whether the catalyst has deteriorated based on the calculated OSC value (See page Engine / Hybrid System>2AZ-FE ENGINE CONTROL>SFI SYSTEM>P0420).
Connect the GTS to the DLC3.
Turn the engine switch on (IG) and turn the GTS on.
Clear DTCs (even if no DTCs are stored, perform the clear DTC operation).
Turn the engine switch off and wait for at least 30 seconds.
Turn the engine switch on (IG) and turn the GTS on [A].
Start the engine and warm it up until the ECT reaches 75°C (167°F) or higher [B].
Within the shift lever in D, drive the vehicle at 60 to 120 km/h (40 to 75 mph) for 10 minutes or more [C].
When performing the confirmation driving pattern, obey all speed limits and traffic laws.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes [D].
Read pending DTCs.
If a pending DTC is output, the system is malfunctioning.
If a pending DTC is not output, perform the following procedure.
Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.
Input the DTC: P0136, P0137 or P0138.
Check the DTC judgment result.
| GTS Display | Description |
|---|---|
| NORMAL | ·
DTC judgment completed ·
System normal |
| ABNORMAL | ·
DTC judgment completed ·
System abnormal |
| INCOMPLETE | ·
DTC judgment not completed ·
Perform driving pattern after confirming DTC enabling conditions |
| N/A | ·
Unable to perform DTC judgment ·
Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit |
Malfunctioning areas can be identified by performing the Control the Injection Volume for A/F Sensor function provided in the Active Test. The Control the Injection Volume for A/F Sensor function can help to determine whether the air fuel ratio sensor, heated oxygen sensor and other potential trouble areas are malfunctioning.
The following instructions describe how to conduct the Control the Injection Volume for A/F Sensor operation using the GTS.
Connect the GTS to the DLC3.
Start the engine.
Turn the GTS on.
Warm up the engine and run the engine at an engine speed of 2500 rpm for approximately 90 seconds.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor / Data List / AFS Voltage B1S1 and O2S B1S2.
Perform the Active Test operation with the engine idling (press the RIGHT or LEFT button to change the fuel injection volume).
Monitor the output voltages of the air fuel ratio and heated oxygen sensors (AFS Voltage B1S1 and O2S B1S2) displayed on the GTS.
The Control the Injection Volume for A/F Sensor operation lowers the fuel injection volume by 12.5% or increases the injection volume by 12.5%.
Each sensor reacts in accordance with increases and decreases in the fuel injection volume.
| GTS Display
(Sensor) |
Injection Volume | Status | Voltage |
|---|---|---|---|
| AFS Voltage B1S1
(Air fuel ratio) |
12.5% | Rich | Below 3.1 V |
| -12.5% | Lean | Higher than 3.4 V | |
| O2S B1S2
(Heated oxygen) |
12.5% | Rich | Higher than 0.55 V |
| -12.5% | Lean | Below 0.4 V |
The air fuel ratio sensor has an output delay of a few seconds and the heated oxygen sensor has a maximum output delay of approximately 20 seconds.
| Case | Air Fuel Ratio Sensor (Sensor 1) Output Voltage | Heated Oxygen Sensor (Sensor 2) Output Voltage | Main Suspected Trouble Area |
|---|---|---|---|
| 1 |
0.135,0.302 1.719,0.76
1.583,0.458
10
false
Injection Volume
1.375,0.75 2.26,1.083
0.885,0.333
10
false
12.5%
1.333,1.167 2.219,1.5
0.885,0.333
10
false
-12.5%
2.896,0.969 3.427,1.25
0.531,0.281
10
false
OK
0.948,1.167 2.021,1.5
1.073,0.333
10
false
Below 3.1 V
0.625,0.792 2.115,1.167
1.49,0.375
10
false
Higher than 3.4 V
0.156,0.24 1.438,0.635
1.281,0.396
10
false
Output Voltage
|
0.135,0.302 1.719,0.76
1.583,0.458
10
false
Injection Volume
1.375,0.75 2.26,1.083
0.885,0.333
10
false
12.5%
1.333,1.167 2.219,1.5
0.885,0.333
10
false
-12.5%
0.583,0.76 2.042,1.198
1.458,0.438
10
false
Higher than 0.55 V
0.969,1.135 1.938,1.448
0.969,0.313
10
false
Below 0.4 V
0.208,0.271 1.635,0.677
1.427,0.406
10
false
Output Voltage
2.896,0.948 3.427,1.26
0.531,0.313
10
false
OK
|
- |
| 2 |
0.135,0.302 1.719,0.76
1.583,0.458
10
false
Injection Volume
1.375,0.75 2.26,1.083
0.885,0.333
10
false
12.5%
1.333,1.167 2.219,1.5
0.885,0.333
10
false
-12.5%
2.875,1.052 3.427,1.333
0.552,0.281
10
false
NG
0.51,1.156 1.823,1.521
1.313,0.365
10
false
Almost no reaction
0.354,0.469 1.49,0.906
1.135,0.438
10
false
Output Voltage
|
0.135,0.302 1.719,0.76
1.583,0.458
10
false
Injection Volume
1.375,0.75 2.26,1.083
0.885,0.333
10
false
12.5%
1.333,1.167 2.219,1.5
0.885,0.333
10
false
-12.5%
0.583,0.76 2.042,1.198
1.458,0.438
10
false
Higher than 0.55 V
0.969,1.135 1.938,1.448
0.969,0.313
10
false
Below 0.4 V
0.208,0.271 1.635,0.677
1.427,0.406
10
false
Output Voltage
2.896,0.948 3.427,1.26
0.531,0.313
10
false
OK
|
·
Air fuel ratio sensor (sensor 1) ·
Air fuel ratio sensor (sensor 1) heater ·
Air fuel ratio sensor (sensor 1) circuit |
| 3 |
0.135,0.302 1.719,0.76
1.583,0.458
10
false
Injection Volume
1.375,0.75 2.26,1.083
0.885,0.333
10
false
12.5%
1.333,1.167 2.219,1.5
0.885,0.333
10
false
-12.5%
2.896,0.969 3.427,1.25
0.531,0.281
10
false
OK
0.948,1.167 2.021,1.5
1.073,0.333
10
false
Below 3.1 V
0.625,0.792 2.115,1.167
1.49,0.375
10
false
Higher than 3.4 V
0.156,0.24 1.438,0.635
1.281,0.396
10
false
Output Voltage
|
0.135,0.302 1.719,0.76
1.583,0.458
10
false
Injection Volume
1.375,0.75 2.26,1.083
0.885,0.333
10
false
12.5%
1.333,1.167 2.219,1.5
0.885,0.333
10
false
-12.5%
2.875,1.052 3.427,1.333
0.552,0.281
10
false
NG
0.51,1.156 1.823,1.521
1.313,0.365
10
false
Almost no reaction
0.354,0.469 1.49,0.906
1.135,0.438
10
false
Output Voltage
|
·
Heated oxygen sensor (sensor 2) ·
Heated oxygen sensor (sensor 2) heater ·
Heated oxygen sensor (sensor 2) circuit |
| 4 |
0.135,0.302 1.719,0.76
1.583,0.458
10
false
Injection Volume
1.375,0.75 2.26,1.083
0.885,0.333
10
false
12.5%
1.333,1.167 2.219,1.5
0.885,0.333
10
false
-12.5%
2.875,1.052 3.427,1.333
0.552,0.281
10
false
NG
0.51,1.156 1.823,1.521
1.313,0.365
10
false
Almost no reaction
0.354,0.469 1.49,0.906
1.135,0.438
10
false
Output Voltage
|
0.135,0.302 1.719,0.76
1.583,0.458
10
false
Injection Volume
1.375,0.75 2.26,1.083
0.885,0.333
10
false
12.5%
1.333,1.167 2.219,1.5
0.885,0.333
10
false
-12.5%
2.875,1.052 3.427,1.333
0.552,0.281
10
false
NG
0.51,1.156 1.823,1.521
1.313,0.365
10
false
Almost no reaction
0.354,0.469 1.49,0.906
1.135,0.438
10
false
Output Voltage
|
·
Fuel injector ·
Fuel pressure ·
Gas leak from exhaust system (air fuel ratio extremely rich or lean) |
Following the Control the Injection Volume for A/F Sensor procedure enables technicians to check and graph the voltage outputs of both the air fuel ratio and heated oxygen sensors.
To display the graph, enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor / Data List / AFS Voltage B1S1 and O2S B1S2; then press the view button.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Sensor 1 refers to the sensor closest to the engine assembly.
Sensor 2 refers to the sensor farthest away from the engine assembly.
Read freeze frame data using the GTS. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Read the DTCs.
| Result | Proceed to |
|---|---|
| DTC P0138 is output | A |
| DTC P0137 is output | B |
| DTC P0136 is output | C |
| DTC P0136, P0137 or P0138 and other DTCs are output | D |
If any DTCs other than P0136, P0137 and P0138 are output, troubleshoot those DTCs first.
A
B
C
D
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Start the engine.
Enter the following menus: Powertrain / Engine and ECT / Data List / O2S B1S2.
Allow the engine to idle.
Read the heated oxygen sensor output voltage while idling.
| Heated Oxygen Sensor Output Voltage | Proceed to |
|---|---|
| 1.0 V or higher | A |
| Less than 1.0 V | B |
A
B
Disconnect the HO2 sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connections | Condition | Specified Conditions |
|---|---|---|
| 2 (+B) - 4 (E2) | Always | 10 kΩ or higher |
| 2 (+B) - 3 (OX1B) | Always | 10 kΩ or higher |
OK
NG
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connections | Condition | Specified Conditions |
|---|---|---|
| D2-47 (HT1B) - D2-64 (OX1B) | Always | 10 kΩ or higher |
OK
NG
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Start the engine.
Warm up the engine.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor / Data List / AFS Voltage B1S1 and O2S B1S2.
Change the fuel injection volume using the GTS and monitor the voltage output of the air fuel ratio and heated oxygen sensors displayed on the GTS.
The Control the Injection Volume for A/F Sensor operation lowers the fuel injection volume by 12.5% or increases the injection volume by 12.5%.
The air fuel ratio sensor is displayed as AFS Voltage B1S1, and the heated oxygen sensor is displayed as O2S B1S2 on the GTS.
The air fuel ratio sensor has an output delay of a few seconds and the heated oxygen sensor has a maximum output delay of approximately 20 seconds.
If the sensor output voltage does not change (almost no reaction) while performing the Active Test, the sensor may be malfunctioning.
| GTS Display
(Sensor) |
Voltage Variation | Proceed to |
|---|---|---|
| AFS Voltage B1S1
(Air fuel ratio) |
Alternates between higher and less than 3.3 V | OK |
| Remains higher than 3.3 V | NG | |
| Remains less than 3.3 V | NG |
A normal heated oxygen sensor voltage (O2S B1S2) reacts in accordance with increases and decreases in fuel injection volumes. When the air fuel ratio sensor (AFS Voltage B1S1) voltage remains either less or higher than 3.3 V despite the heated oxygen sensor indicating a normal reaction, the air fuel ratio sensor is malfunctioning.
OK
NG
This air fuel ratio sensor test is to check the air fuel ratio sensor current during the fuel-cut operation. When the sensor is normal, the sensor current will indicate less than 3.6 mA in this test.
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Clear the DTCs (See page Engine / Hybrid System>2AZ-FE ENGINE CONTROL>SFI SYSTEM>DTC CHECK / CLEAR).
Start the engine and warm it up until the engine coolant temperature reaches 75°C (167°F) or higher.
Drive the vehicle at 60 km/h (37 mph) or more for 10 minutes or more.
When performing the confirmation driving pattern, obey all speed limits and traffic laws.
Stop the vehicle.
Enter the following menus: Powertrain / Engine and ECT / Data List / AFS Current B1S1.
Drive the vehicle at 60 km/h (37 mph) or more and decelerate the vehicle for 5 seconds or more. Perform this 3 times.
When performing the confirmation driving pattern, obey all speed limits and traffic laws.
Read the value of the air fuel ratio sensor current while the fuel-cut operation is being performed.
Less than 3.6 mA
To measure the air fuel ratio sensor current precisely, perform the fuel-cut operation as long as possible.
If it is difficult to measure the air fuel ratio sensor current, use the snapshot function of the GTS.
OK
NG
Connect the GTS to the DLC3.
Start the engine.
Turn the GTS on.
Warm up the engine.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor / Data List / O2S B1S2.
Change the fuel injection volume using the GTS and monitor the voltage output of the heated oxygen sensors displayed on the GTS.
The Control the Injection Volume for A/F Sensor operation lowers the fuel injection volume by 12.5% or increases the injection volume by 12.5%.
The heated oxygen sensor has a maximum output delay of approximately 20 seconds.
Fluctuates between 0.4 V or less and 0.55 V or higher.
OK
NG
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Start the engine.
Warm up the engine.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor / Data List / AFS Voltage B1S1 and O2S B1S2.
Change the fuel injection volume using the GTS and monitor the voltage output of the air fuel ratio and heated oxygen sensors displayed on the GTS.
The Control the Injection Volume for A/F Sensor operation lowers the fuel injection volume by 12.5% or increases the injection volume by 12.5%.
The air fuel ratio sensor is displayed as AFS Voltage B1S1, and the heated oxygen sensor is displayed as O2S B1S2 on the GTS.
The air fuel ratio sensor has an output delay of a few seconds and the heated oxygen sensor has a maximum output delay of approximately 20 seconds.
If the sensor output voltage does not change (almost no reaction) while performing the Active Test, the sensor may be malfunctioning.
| GTS Display
(Sensor) |
Voltage Variation | Proceed to |
|---|---|---|
| AFS Voltage B1S1
(Air fuel ratio) |
Alternates between higher and less than 3.3 V | OK |
| Remains higher than 3.3 V | NG | |
| Remains less than 3.3 V | NG |
A normal heated oxygen sensor voltage (O2S B1S2) reacts in accordance with increases and decreases in fuel injection volumes. When the air fuel ratio sensor (AFS Voltage B1S1) voltage remains either less or higher than 3.3 V despite the heated oxygen sensor indicating a normal reaction, the air fuel ratio sensor is malfunctioning.
OK
NG
Check for exhaust gas leak.
No gas leak.
OK
NG
OK
NG
Disconnect the HO2 sensor connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connections | Condition | Specified Conditions |
|---|---|---|
| D59-1 (HT1B) - D2-47 (HT1B) | Always | Below 1 Ω |
| D59-3 (OX1B) - D2-64 (OX1B) | Always | Below 1 Ω |
| D59-4 (E2) - D2-87 (EX1B) | Always | Below 1 Ω |
| Tester Connections | Condition | Specified Conditions |
|---|---|---|
| D59-1 (HT1B) or D2-47 (HT1B) - Body ground | Always | 10 kΩ or higher |
| D59-3 (OX1B) or D2-64 (OX1B) - Body ground | Always | 10 kΩ or higher |
OK
NG
Replace the heated oxygen sensor (See page Engine / Hybrid System>2AZ-FE EMISSION CONTROL>HEATED OXYGEN SENSOR>REMOVAL).
NEXT
Perform the Confirmation Driving Pattern.
NEXT
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.
Input the DTC: P0136, P0137 or P0138.
Check that the DTC monitor is NORMAL. If the DTC monitor is INCOMPLETE, perform the driving pattern again but increase the vehicle speed.
| Result | Proceed to |
|---|---|
| ABNORMAL
(DTC P0136, P0137 or P0138 is output) |
A |
| NORMAL
(DTC is not output) |
B |
A
B
Replace the air fuel ratio sensor (See page Engine / Hybrid System>2AZ-FE EMISSION CONTROL>AIR FUEL RATIO SENSOR>REMOVAL).
NEXT
Perform the Confirmation Driving Pattern.
NEXT
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.
Input the DTC: P0136 or P0138.
Check that the DTC monitor is NORMAL. If the DTC monitor is INCOMPLETE, perform the driving pattern again but increase the vehicle speed.
| Result | Proceed to |
|---|---|
| ABNORMAL
(DTC P0136 or P0138 is output) |
A |
| NORMAL
(DTC is not output) |
B |
A
B