Home › Drivetrain › K112 (CVT) › CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM › 2013.04–2014.09
RM24M0E _52 Drivetrain _059572 K112 CVT _0292047 CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM C

K112 CVT  CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM  P2769  Short in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL)  P2770  Open in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL)  


DESCRIPTION

The ECM turns the shift solenoid valve SL on or off to control the oil pressure applied to the lock-up relay valve and turns lock-up on or off.

DTC No. DTC Detection Condition
1.

Diagnosis Condition

2.

Malfunction Status

3.

Malfunction Time

4.

Other


Trouble Area
P2769
1.

Lock-up is operating.

2.

There is a short circuit in the shift solenoid valve SL circuit.

3.

Detected 2 times or more consecutively

4.

2 trip detection logic


·

Short in shift solenoid valve SL circuit

·

Continuously variable transaxle assembly

·

ECM


P2770
1.

Lock-up is operating.

2.

There is an open circuit in the shift solenoid valve SL circuit.

3.

Detected 2 times or more consecutively

4.

2 trip detection logic


·

Open in shift solenoid valve SL circuit

·

Continuously variable transaxle assembly

·

ECM



MONITOR DESCRIPTION

These DTCs indicate an open or short circuit in the shift solenoid valve SL circuit. When there is an open or short circuit in the shift solenoid valve SL circuit, the ECM detects the problem, illuminates the MIL and stores the DTCs.

WIRING DIAGRAM

C200619E39
5.813,2.938 6.125,3.135 0.313,0.198 10 false D2 5.813,3.115 6.198,3.313 0.385,0.198 10 false ECM 5.625,1.24 6.042,1.438 0.417,0.198 10 false SL 5.323,1.375 5.521,1.573 0.198,0.198 10 false 57 3.313,1.125 3.677,1.323 0.365,0.198 10 false SL 3.635,1.365 3.833,1.563 0.198,0.198 10 false 2 1.49,1.729 3.448,1.927 1.958,0.198 10 false Shift Solenoid Valve SL 1.167,2.677 1.479,2.875 0.313,0.198 10 false D67 1.167,2.865 3.302,3.229 2.135,0.365 10 false Transmission Wire (Continuously Variable Transaxle Assembly)

PROCEDURE

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL)
a.
C199169E04
1.923,0.958 2.465,0.493 false 2.514,0.375 2.933,0.577 0.418,0.202 10 SL 0.07,0.079 0.386,0.280 0.317,0.202 10 *1

Disconnect the transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
2 (SL) - Body ground 20°C (68°F) 11 to 15 Ω


Text in Illustration
*1 Component without harness connected
(Transmission Wire)



OK

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

NG

5.REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLY
2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
a.

Disconnect the ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
D2-57 (SL) - Body ground 20°C (68°F) 11 to 15 Ω




OK

3.REPLACE ECM

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.REPLACE ECM

NEXT

4.PERFORM INITIALIZATION
5.REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLY

NEXT

6.PERFORM INITIALIZATION