Home › Engine / Hybrid System › 2AZ-FE CHARGING › GENERATOR
RM24M0E _51 Engine / Hybrid System _059576 2AZ-FE CHARGING _0292084 GENERATOR A

2AZ-FE CHARGING  GENERATOR  INSTALLATION  


PROCEDURE

Hide 27020 1.INSTALL GENERATOR ASSEMBLY

a.
A097394E06
1.51,0.76 2.042,0.135 2.042,0.135 2.167,0.135 false 1.333,0.396 1.052,0.583 false 2.208,0.031 3.115,0.677 0.906,0.646 10 true Wire Harness Clamp Bracket 0.74,0.521 1.031,0.802 0.292,0.281 10 true Rib

Confirm that the wire harness of the crankshaft position sensor is secured to the wire harness clamp bracket through the back of the rib of the timing chain cover.


b.
A131626E02
1.219,1.979 1.333,2.146 0.115,0.167 10 true A 0.615,0.875 0.75,1.042 0.135,0.167 10 true B

Install the generator with the 2 bolts.

Torque:
21 N*m (215 kgf*cm, 16 ft.*lbf)

for bolt A

52 N*m (530 kgf*cm, 38 ft.*lbf)

for bolt B



c.
A131625

Install the wire harness clamp.


d.

Install the wire harness clamp bracket with the bolt.

Torque:
8.4 N*m (85 kgf*cm, 74 in.*lbf)


e.

Connect the generator wire with the nut.

Torque:
9.8 N*m (100 kgf*cm, 87 in.*lbf)


f.

Install the terminal cap.


g.

Connect the generator connector.


Hide 16361A 2.INSTALL FAN & GENERATOR V BELT

Hide 28800 3.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

Hide 4.PERFORM INITIALIZATION

a.

Perform initialization (See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).

NOTICE:

Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.