Home › Engine / Hybrid System › 2GR-FE CHARGING › GENERATOR
RM24M0E _51 Engine / Hybrid System _059577 2GR-FE CHARGING _0292086 GENERATOR A

2GR-FE CHARGING  GENERATOR  REMOVAL  


PROCEDURE

Hide 28800J 1.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).


Hide 16400 2.REMOVE RADIATOR ASSEMBLY WITH FAN SHROUD AND FAN MOTOR

Hide 27020 4.REMOVE GENERATOR ASSEMBLY

a.
A160953

Remove the 2 bolts.


b.
A395322E01
0.396,1.76 1.313,1.958 0.917,0.198 10 false :Clamp

Remove the terminal cap.


c.

Remove the nut and disconnect the wire harness from terminal B.


d.

Disconnect the generator connector from the generator assembly.


e.

Disconnect the connector from the compressor and magnetic clutch.


f.

Disconnect the wire harness clamp.


g.
A394008

Remove the 2 bolts.


h.
A395323E01
0.385,1.771 1.302,1.969 0.917,0.198 10 false :Clamp

Remove the nut from the cylinder block.


i.

Disconnect the wire harness clamp and remove the generator assembly.


j.
A135391

Remove the bolt and bracket.