P0010 Camshaft Position "A" Actuator Circuit (Bank 1)
Diagnostic trouble codes · Vehicles built Jul 2007 – Jul 2009
Also covers:
- P0020 Camshaft Position "A" Actuator Circuit (Bank 2)
Versions by build date: Jul 2007 – Jul 2009 from Aug 2009
DESCRIPTION
- HINT:
- This DTC relates to the Oil Control Valve (OCV).
The VVT (variable valve timing) system adjusts the intake valve timing to improve the driveability. The engine oil pressure turns the camshaft actuator to adjust the valve timing. The OCV is a solenoid valve and switches the engine oil line. The valve moves when the ECM applies the 12 volts to the solenoid. The ECM changes the energizing time to the solenoid (duty-cycle) in accordance with the camshaft position, crankshaft position, throttle position etc.


| DTC No. |
DTC Detection Conditions |
Trouble Areas |
| P0010 |
Open or short in OCV (bank 1) circuit (1 trip detection logic) |
|
| P0020 |
Open or short in OCV (bank 2) circuit (1 trip detection logic) |
|
MONITOR DESCRIPTION
This DTC is designed to detect opens or shorts in the camshaft oil control valve (OCV) circuit. If the OCV's duty-cycle is excessively high or low while the engine running, the ECM will illuminate the MIL and set the DTC.WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. CHECK FOR DTC (DTC P0010 OR P0020) |
Clear the DTCs after recording the freeze frame data and DTCs.
Allow the engine to idle and check for DTCs.
Check whether P0010 or P0020 is present.
- OK:
- P0010 or P0020 is present.
|
|
||||
| OK | |
| 2. INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY |
![]() ![]() |
Disconnect the OCV connector.
Measure the resistance between the terminals of the OCV.
- Standard Resistance:
Tester Connections
Specified Conditions
1 - 2
6.9 to 7.9 Ω at 20°C (68°F)
Reconnect the OCV connector.
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (OCV - ECM) |
![]() ![]() |
Disconnect the B3 ECM connector.
Disconnect the B12 or B26 OCV connector.
Check the resistance.
- Standard Resistance for Bank 1:
Tester Connections
Specified Conditions
B12-1 - OC1+ (B3-17)
Below 1 Ω
B12-1 - Body ground
10 kΩ or higher
B12-2 - OC1- (B3-16)
Below 1 Ω
B12-2 - Body ground
10 kΩ or higher
- Standard Resistance for Bank 2:
Tester Connections
Specified Conditions
B26-1 - OC2+ (B3-15)
Below 1 Ω
B26-1 - Body ground
10 kΩ or higher
B26-2 - OC2- (B3-14)
Below 1 Ω
B26-2 - Body ground
10 kΩ or higher
Reconnect the ECM connector.
Reconnect the OCV connector.
|
|
||||
| OK | ||
| ||