P0010 Camshaft Position "A" Actuator Circuit (Bank 1)
Diagnostic trouble codes · Vehicles built from Aug 2009
Also covers:
- P0020 Camshaft Position "A" Actuator Circuit (Bank 2)
Versions by build date: Jul 2007 – Jul 2009 from Aug 2009
DESCRIPTION
- This DTC is designed to detect opens or shorts in the Camshaft Timing Oil Control Valve (OCV) assembly circuit. If the OCV's duty-cycle is excessively high or low while the engine is running, the ECM will illuminate the MIL and store the DTC.
- The VVT (Variable Valve Timing) system adjusts the intake valve timing to improve the driveability. The engine oil pressure turns the camshaft timing gear assembly to adjust the valve timing. The OCV is a solenoid valve and switches the engine oil line. The valve moves when the ECM applies 12 V to the solenoid. The ECM changes the energizing time to the solenoid (duty-cycle) in accordance with the camshaft position, crankshaft position, throttle position, etc.


| DTC No. |
DTC Detection Condition |
Trouble Area |
| P0010 |
Open or short in OCV (for intake side of bank 1) circuit (1 trip detection logic) |
|
| P0020 |
Open or short in OCV (for intake side of bank 2) circuit (1 trip detection logic) |
|
- HINT:
- This DTC relates to the Oil Control Valve (OCV).
MONITOR DESCRIPTION
This DTC is designed to detect opens or shorts in the Camshaft Timing Oil Control Valve (OCV) assembly circuit. If the OCV's duty-cycle is excessively high or low while the engine is running, the ECM will illuminate the MIL and stores the DTC.WIRING DIAGRAM


INSPECTION PROCEDURE
- HINT:
- Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.
| 1. CHECK DTC (P0010 OR P0020) |
Connect the intelligent tester to the DLC3.
Clear DTC after recording the freeze frame data and DTC (Click here).
Turn the ignition switch off.
Allow the engine to idle and check DTC.
Check that P0010 or P0020 is not present.
- OK:
- P0010 or P0020 is not present.
|
|
||||
| OK | ||
| ||
| 2. INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY |
Disconnect the camshaft timing oil control valve assembly connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
6.9 to 7.9 Ω
Text in Illustration *1
Component without harness connected
(Camshaft Timing Oil Control Valve Assembly)
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (OCV - ECM) |
Disconnect the OCV connector.
Disconnect the ECM connectors.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance (Check for Open):
Tester Connection
Condition
Specified Condition
B61-1 - B48-19 (OC1+)
Always
Below 1 Ω
B61-2 - B48-20 (OC1-)
Always
Below 1 Ω
B62-1 - B47-19 (OC2+)
Always
Below 1 Ω
B62-2 - B47-20 (OC2-)
Always
Below 1 Ω
- Standard Resistance (Check for Short):
Tester Connection
Condition
Specified Condition
B61-1 or B48-19 (OC1+) - Body ground
Always
10 kΩ or higher
B61-2 or B48-20 (OC1-) - Body ground
Always
10 kΩ or higher
B62-1 or B47-19 (OC2+) - Body ground
Always
10 kΩ or higher
B62-2 or B47-20 (OC2-) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | ||
| ||