P0327 Knock Sensor 1 Circuit Low Input (Bank 1 or Single Sensor)
Diagnostic trouble codes · Vehicles built Jul 2007 – Jul 2009
Also covers:
- P0328 Knock Sensor 1 Circuit High Input (Bank 1 or Single Sensor)
- P0332 Knock Sensor 2 Circuit Low Input (Bank 2)
- P0333 Knock Sensor 2 Circuit High Input (Bank 2)
Versions by build date: Jul 2007 – Jul 2009 from Aug 2009
DESCRIPTION
A flat type knock sensor (non-resonant type) has a structure that can detect vibrations over a wide band of frequencies: between approximately 6 kHz and 15 kHz.Knock sensors are fitted onto the engine block to detect engine knocking.
The knock sensor contains a piezoelectric element which generates a voltage when it becomes deformed.
The voltage is generated when the engine block vibrates due to knocking. Any occurrence of engine knocking can be suppressed by delaying the ignition timing.
| DTC No. |
DTC Detection Conditions |
Trouble Areas |
| P0327 P0332 |
Output voltage of knock sensor 1 or 2 is 0.5 V or less (1 trip detection logic) |
|
| P0328 P0333 |
Output voltage of knock sensor 1 or 2 is 4.5 V or more (1 trip detection logic) |
|
- HINT:
- When any of DTCs P0327, P0328, P0332 and P0333 are set, the ECM enters fail-safe mode. During fail- safe mode, the ignition timing is delayed to its maximum retardation. Fail-safe mode continues until the ignition switch is turned OFF.
-


- Reference: Inspection using an oscilloscope
The correct waveform is as shown.Items
Contents
Terminals
KNK1 - EKNK
or
KNK2 - EKN2
Equipment Settings
1 V/DIV,
1 msec./DIV
Conditions
Keep engine speed at 4,000 rpm with
warm engine
MONITOR DESCRIPTION
If the output voltage transmitted by the knock sensor remains low or high for more than 1 second, the ECM interprets this as a malfunction in the sensor circuit, and sets a DTC.The monitor for DTCs P0327, P0328, P0332 and P0333 begins to run when 5 seconds have elapsed since the engine was started.
If the malfunction is not repaired successfully, any of DTC P0327, P0328, P0332 or P0333 is set 5 seconds after the engine is next started.
WIRING DIAGRAM


INSPECTION PROCEDURE
- HINT:
- DTCs P0327 and P0328 are for the bank 1 knock sensor circuit.
- DTCs P0327 and P0328 are for the bank 1 knock sensor circuit.
- DTCs P0332 and P0333 are for the bank 2 knock sensor circuit.
- DTCs P0332 and P0333 are for the bank 2 knock sensor circuit.
- Read freeze frame data using an intelligent tester. Freeze frame data record the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data, from the time the malfunction occurred.
- Read freeze frame data using an intelligent tester. Freeze frame data record the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data, from the time the malfunction occurred.
| 1. READ OUTPUT DTC (CHECK KNOCK SENSOR CIRCUIT) |
![]() ![]() |
Disconnect the BU1 connector.
Using lead wires, connect the connectors as follows.
Male Connector - Female Connector
Terminal 2 - Terminal 4
Terminal 5 - Terminal 6
Terminal 4 - Terminal 2
Terminal 6 - Terminal 5
Warm up the engine.
Run the engine at 3,000 rpm for 10 seconds or more.
Connect an intelligent tester to the DLC3.
Turn the ignition switch ON and turn the tester ON.
Select the item: Powertrain / Engine and ECT / DTC.
Read DTCs.
- Result:
Display
Proceed To
DTCs same as when vehicle brought in
P0327, P0328 → P0327, P0328
or
P0332, P0333 → P0332, P0333
A
DTCs different from when vehicle brought in
P0327, P0328 → P0332, P0333
or
P0332, P0333 → P0327, P0328
B
Reconnect the BU1 connector.
|
|
||||
| A | |
| 2. CHECK HARNESS AND CONNECTOR (CONNECTOR - ECM) |
![]() ![]() |
Disconnect the BU1 connector.
Disconnect the B2 ECM connector.
Check the resistance.
- Standard Resistance (Check for open):
Tester Connections
Specified Conditions
BU1 female connector 2 - KNK1 (B2-29)
Below 1 Ω
BU1 female connector 5 - EKNK (B2-28)
BU1 female connector 4 - KNK2 (B2-21)
BU1 female connector 6 - EKN2 (B2-20)
- Standard Resistance (Check for short):
Tester Connections
Specified Conditions
BU1 female connector 2 or KNK1 (B2-29) - Body ground
10 kΩ or higher
BU1 female connector 5 or EKNK (B2-28) - Body ground
BU1 female connector 4 or KNK2 (B2-21) - Body ground
BU1 female connector 6 or EKN2 (B2-20) - Body ground
Reconnect the BU1 connector.
Reconnect the ECM connector.
|
|
||||
| OK | |
| 3. INSPECT ECM |
![]() ![]() |
Disconnect the B2 ECM connector.
Turn the ignition switch ON.
Measure the voltage between the ECM terminals.
- Standard Voltage:
Tester Connections
Specified Conditions
KNK1 (B2-29) - EKNK (B2-28)
4.5 to 5.5 V
KNK2 (B2-21) - EKN2 (B2-20)
Reconnect the ECM connector.
|
|
||||
| OK | ||
| ||
| 4. INSPECT KNOCK SENSOR |
![]() ![]() |
Disconnect the BU1 connector.
Check the resistance between the terminals of the BU1 male connector.
- Standard Resistance:
Tester Connections
Specified Conditions
BU1 male connector 2 - 5
120 to 280 kΩ
BU1 male connector 4 - 6
Reconnect the BU1 connector.
|
|
||||
| NG | |
| 5. CHECK HARNESS AND CONNECTOR (CONNECTOR - KNOCK SENSOR) |
![]() ![]() |
- HINT:
- If DTC P0327 or P0328 has changed to P0332 or P0333, check the knock sensor circuit on the right bank side.
- If DTC P0327 or P0328 has changed to P0332 or P0333, check the knock sensor circuit on the right bank side.
- If DTC P0332 or P0333 has changed to P0327 or P0328, check the knock sensor circuit on the left bank side.
- If DTC P0332 or P0333 has changed to P0327 or P0328, check the knock sensor circuit on the left bank side.
Disconnect the BU1 connector.
Disconnect the U1 and U2 knock sensor connectors.
Check the resistance.
- Standard Resistance (Check for open):
Tester Connections
Specified Conditions
BU1 male connector 2 - U2-2
Below 1 Ω
BU1 male connector 5 - U2-1
BU1 male connector 4 - U1-2
BU1 male connector 6 - U1-1
- Standard Resistance (Check for short):
Tester Connections
Specified Conditions
BU1 male connector 2 or U2-2 - Body ground
10 kΩ or higher
BU1 male connector 5 or U2-1 - Body ground
BU1 male connector 4 or U1-2 - Body ground
BU1 male connector 6 or U1-1 - Body ground
Reconnect the BU1 connector.
Reconnect the knock sensor connector.
|
|
||||
| OK | ||
| ||