P2714 Pressure Control Solenoid "D" Performance (Shift Solenoid Valve SLT)
Diagnostic trouble codes · Vehicles built Jul 2007 – Nov 2007
Versions by build date: Jul 2007 – Nov 2007 from Aug 2009
DESCRIPTION


Shift solenoid valve SLT controls the transmission line pressure for smooth transmission operation based on signals from the throttle position sensor and vehicle speed sensor. The ECM adjusts the current to shift solenoid valve SLT to control the hydraulic line pressure coming from the primary regulator valve. Appropriate line pressure assures smooth shifting with varying engine outputs.
| DTC No. |
DTC Detection Condition |
Trouble Area |
| P2714 |
ECM detects malfunctions on SLT (ON side) according to the revolution difference between the turbine and the output shaft, and also by monitoring the oil pressure. (1-trip detection logic) |
|
MONITOR DESCRIPTION
The ECM calculates the amount of heat absorbed by the friction material based on the difference in revolution (clutch slippage) between the turbine and output shaft. The ECM outputs this DTC when the amount of heat absorption exceeds the specified value.When the shift solenoid valve SLT remains on, the oil pressure goes down and the clutch engagement force decreases.
NOTE: If driving continues under these conditions, the clutch will burn out and the vehicle will no longer be drivable.
INSPECTION PROCEDURE
| 1. CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P2714) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester ON.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Read the DTCs using the intelligent tester.
Result: Display (DTC Output)
Proceed to
Only "P2714" is output
A
"P2714" and other DTCs
B
- HINT:
- If any codes besides "P2714" are output, perform troubleshooting for those DTCs first.
|
|
||||
| A | |
| 2. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (SHIFT SOLENOID VALVE SLT) |
![]() ![]() |
- NOTICE:
- Perform the test at the normal operating ATF (Automatic Transmission Fluid) temperature: 50 to 80°C (122 to 176°F).
- Be careful to prevent SST's hose from interfering with the exhaust pipe.
- Perform the test with the A/C OFF.
- Perform the test at the normal operating ATF (Automatic Transmission Fluid) temperature: 50 to 80°C (122 to 176°F).
- HINT:
- Performing a intelligent tester Active Test allows relay, VSV, actuator and other items to be operated without removing any parts. Performing the Active Test early in troubleshooting is one way to save time.
- The Data List can be displayed during the Active Test.
Remove the test plug on the transmission case center right side and connect SST.
- SST
- 09992-00095
(09992-00231, 09992-00271)
Connect a intelligent tester to the DLC3.
Start the engine and warm it up.
Measure the line pressure with SST.
Turn the tester ON.
Enter the following menus: Powertrain / Engine and ECT / Active Test.
According to the display on the tester, perform the Active Test.
Measure the line pressure with SST.
*: Active the Solenoid (SLT) in the Active Test is performed to check the line pressure changes by connecting SST to the automatic transmission, which is used in the HYDRAULIC TEST (Click here) as well. Please note that the pressure values in the Active Test and HYDRAULIC TEST are different.Tester Display
Test Part
Control Range
Diagnostic Note
Active the Solenoid (SLT)*
Operate the shift solenoid SLT and raise line pressure
ON or OFF - HINT:
- OFF: Line pressure up (when Active Test "Active the Solenoid (SLT)" is performed, ECM commands SLT solenoid to turn OFF)
- ON: No action (normal operation)
- OFF: Line pressure up (when Active Test "Active the Solenoid (SLT)" is performed, ECM commands SLT solenoid to turn OFF)
[Vehicle Condition] - Vehicle stopped
- Engine idling
|
|
||||
| OK | |
| 3. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (SHIFT) |
- HINT:
- Performing the Active Test using a intelligent tester allows components, such as the relay, VSV, and actuator, to be operated without removing any parts. Performing the Active Test as a first step of troubleshooting is one method of shortening labor time.
- It is possible to display the Data List during the Active Test.
- Warm up the engine.
- Turn the ignition switch to OFF.
- Connect the intelligent tester to the DLC3.
- Turn the ignition switch to ON.
- Turn the tester ON.
- Enter the following menus: Powertrain / Engine and ECT / Active Test.
- According to the display on the tester, perform the Active Test.
- Warm up the engine.
- HINT:
- While driving, the shift position can be changed with the intelligent tester.
- Comparing the shift position directed by the Active Test with the actual shift position enables the problem to be confirmed (Click here).
| Tester Display |
Test Part |
Control Range |
Diagnostic Note |
| Control the Shift Position |
Operate shift solenoid valve and set each shift position by yourself |
|
Possible to check operation of shift solenoid valves [Vehicle Condition] 50 km/h (30 mph) or less |
- HINT:
- This test can be conducted when the vehicle speed is 50 km/h (30 mph) or less.
- The 4th to 5th up-shifting must be performed with the accelerator pedal released.
- The 5th to 4th down-shifting must be performed with the accelerator pedal released.
- Do not operate the accelerator pedal for at least 2 seconds after shifting and do not shift successively.
- The shift position directed by the ECM is shown in the Data List / Shift Status display on the intelligent tester.
- This test can be conducted when the vehicle speed is 50 km/h (30 mph) or less.
Compare the ECM gear shift command and the actual gear position.
ECM gear shift command
1st
2nd
3rd
4th
5th
Proceed to
Actual gear position under malfunction
Shift solenoid S1
Stuck ON
1st
2nd
2nd
1st
N*1
A
Stuck OFF
4th
3rd
3rd
4th
5th
Shift solenoid S2
Stuck ON*2
2nd
2nd
3rd
3rd
N*1
B
Stuck OFF*3
1st
1st
4th
4th
5th
Shift solenoid SL2
Stuck ON
1st
2nd
3rd
4th
N*1
C
Stuck OFF
1st
2nd
3rd
4th
5th
Shift solenoid SR
Stuck ON*4
1st
2nd
3rd
4th
5th
D
Stuck OFF*5
1st
2nd
3rd
4th
4th
- HINT:
-
*1: Neutral
-
*2: When shift solenoid S2 is stuck ON, the vehicle cannot drive in reverse.
-
*3: When shift solenoid S2 is stuck OFF, the 4th to 5th up-shift will have a large shift shock. Also the 5th to 4th down-shift will have time lag.
-
*4: Stuck ON condition can be determined by checking if shift shock has increased excessively.
-
*5: When shift solenoid SR is stuck OFF, moving the shift lever from N to D will cause a large shift shock.
- Gear shift can be determined by paying attention to changes in rpm.
-
*1: Neutral
|
|
||||
|
|
||||
|
|
||||
|
|
||||
| A | |
| 4. INSPECT SHIFT SOLENOID VALVE S1 |
Remove the shift solenoid valve S1.

Measure the resistance.
- Standard resistance:
Tester Connection
Specified Condition
Solenoid Connector (S1) - Solenoid Body (S1)
11 to 15 Ω at 20°C (68°F)
Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.
- OK:
- The solenoid makes operating sounds.
|
|
||||
| NG | ||
| ||
| 5. INSPECT SHIFT SOLENOID VALVE S2 |
Remove the shift solenoid valve S2.

Measure the resistance.
- Standard resistance:
Tester Connection
Specified Condition
Solenoid Connector (S2) - Solenoid Body (S2)
11 to 15 Ω at 20°C (68°F)
Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.
- OK:
- The solenoid makes operating sounds.
|
|
||||
| NG | ||
| ||
| 6. INSPECT SHIFT SOLENOID VALVE SL2 |
Remove the shift solenoid valve SL2.

Measure the resistance.
- Standard resistance:
Tester Connection
Specified Condition
1 - 2
5.0 to 5.6 Ω at 20°C (68°F)
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
- OK:
- The solenoid makes operating sounds.
|
|
||||
| NG | ||
| ||
| 7. INSPECT SHIFT SOLENOID VALVE SR |
Remove the shift solenoid valve SR.

Measure the resistance.
- Standard resistance:
Tester Connection
Specified Condition
Solenoid Connector (SR) - Solenoid Body (SR)
11 to 15 Ω at 20°C (68°F)
Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.
- OK:
- The solenoid makes operating sounds.
|
|
||||
| OK | |
| 8. INSPECT SHIFT SOLENOID VALVE SL1 |
Remove the shift solenoid valve SL1.

Measure the resistance.
- Standard resistance:
Tester Connection
Specified Condition
1 - 2
5.0 to 5.6 Ω at 20°C (68°F)
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
- OK:
- The solenoid makes operating sounds.
|
|
||||
| NG | ||
| ||
| 9. INSPECT SHIFT SOLENOID VALVE SLT |
Remove the shift solenoid valve SLT.

Measure the resistance.
- Standard resistance:
Tester Connection
Specified Condition
1 - 2
5.0 to 5.6 Ω at 20°C (68°F)
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
- OK:
- The solenoid makes operating sounds.
|
|
||||
| OK | |
| 10. INSPECT TRANSMISSION VALVE BODY ASSEMBLY (See chapter 2 in the problem symptoms table) |
- OK:
- There are no foreign objects on any valves and they operate smoothly.
|
|
||||
| OK | |
| 11. INSPECT TORQUE CONVERTER CLUTCH ASSEMBLY |
Check the torque converter clutch assembly (Click here).
- OK:
- The torque converter clutch operates normally.
|
|
||||
| OK | ||
| ||