Home › ENGINE › 1GR-FE ENGINE CONTROL SYSTEM › SFI SYSTEM
Starter Signal Circuit
Circuit diagnosis · Vehicles built Aug 2009 – Oct 2010
Versions by build date: Aug 2009 – Oct 2010 Nov 2010 – Jul 2012 from Aug 2012
DESCRIPTION
While the engine is being cranked, current flows from the ignition switch to terminal STA of the ECM as well as to the STA relay. For the automatic transmission model, current flows through the park/ neutral position switch to the ECM. WIRING DIAGRAM
INSPECTION PROCEDURE
NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
1. READ VALUE USING INTELLIGENT TESTER (STARTER SIGNAL)
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Starter Signal.
Check the value displayed on the tester when the ignition switch is turned to the ON and START position.
OK:
Condition
Starter Signal
ON
Close
Start
Open
Result
Result
Proceed to
Outside standard range (for Manual Transmission Model)
A
Outside standard range (for Automatic Transmission Model)
B
Within standard range (for Manual Transmission Model)
C
Within standard range (for Automatic Transmission Model)
D
A
2. INSPECT IGNITION SWITCH
Disconnect the ignition switch connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
2 (AM1) - 1 (ST1)
START position
Below 1 Ω
Text in Illustration
*1
Component without harness connected (Ignition Switch)
NG
OK
3. CHECK HARNESS AND CONNECTOR (IGNITION SWITCH - ECM - STA RELAY)
Remove the STA relay.
Disconnect the ECM connector.
Disconnect the ignition switch connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance (Check for Open):
Tester Connection
Switch Condition
Specified Condition
STA relay terminal 1- B81-10 (STA)
Always
Below 1 Ω
STA relay terminal 1- A1-1 (ST1)
Shift position P, N
Below 1 Ω
Standard Resistance (Check for Short):
Tester Connection
Condition
Specified Condition
B81-10 (STA) or A1-1 (ST1) - Body ground
Always
10 kΩ or higher
Result
Result
Proceed to
Outside standard range
A
Within standard range
B
B
A
REPAIR OR REPLACE HARNESS OR CONNECTOR
4. INSPECT PARK/NEUTRAL POSITION SWITCH
Disconnect the park/neutral position switch connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
4 - 5
Shift position P, N
Below 1 Ω
Text in Illustration
*1
Component without harness connected (Park/Neutral Position Switch)
NG
OK
5. INSPECT IGNITION SWITCH
Disconnect the ignition switch connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
2 (AM1) - 1 (ST1)
START position
Below 1 Ω
Text in Illustration
*1
Component without harness connected (Ignition Switch)
NG
OK
6. CHECK HARNESS AND CONNECTOR (IGNITION SWITCH - PARK/NEUTRAL POSITION SWITCH)
Disconnect the ignition switch connector.
Disconnect the park/neutral position switch connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance (Check for Open):
Tester Connection
Condition
Specified Condition
A1-1 (ST1) - B35-4
Always
Below 1 Ω
Standard Resistance (Check for Short):
Tester Connection
Condition
Specified Condition
A1-1 (ST1) or B35-4 - Body ground
Always
10 kΩ or higher
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
7. CHECK HARNESS AND CONNECTOR (PARK/NEUTRAL POSITION SWITCH - ECM - STA RELAY)
Remove the STA relay from the engine room relay block.
Disconnect the ECM connector.
Disconnect the park/neutral position switch connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance (Check for Open):
Tester Connection
Condition
Specified Condition
STA relay terminal 1 - E81-10 (STA)
Always
Below 1 Ω
STA relay terminal 1 - B35-5
Always
Below 1 Ω
Standard Resistance (Check for Short):
Tester Connection
Condition
Specified Condition
E81-10 (STA) or B35-5 - Body ground
Always
10 kΩ or higher
Result
Result
Proceed to
Outside standard range
A
Within standard range
B
B
A
REPAIR OR REPLACE HARNESS OR CONNECTOR
8. INSPECT BATTERY
Check that the battery is not depleted.
OK:
Battery is not depleted.
NG
OK
9. CHECK BATTERY TERMINAL
Check that the battery terminals are not loose or corroded.
OK:
Battery terminals are not loose or corroded.
NG
REPAIR OR REPLACE BATTERY TERMINAL
OK
REPAIR OR REPLACE STARTER CIRCUIT (STARTER - STA RELAY)