P0135 Oxygen Sensor Heater Circuit (Bank 1 Sensor 1)
Diagnostic trouble codes · Vehicles built Oct 2014 – Dec 2014
Versions by build date: Oct 2014 – Dec 2014 from Jan 2015
DESCRIPTION
Refer to DTC P0130 (Click here).| DTC No. |
DTC Detection Condition |
Trouble Area |
| P0135 |
Open or short in the heater circuit of the oxygen sensor for 0.5 seconds or more (1 trip detection logic). |
|
WIRING DIAGRAM
Refer to DTC P0130 (Click here).INSPECTION PROCEDURE
- NOTICE:
- Inspect the fuses for circuits related to this system before performing the following inspection procedure.
- HINT:
- Read freeze frame data using the intelligent tester. Freeze frame data records the engine conditions when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.
| 1. INSPECT HEATED OXYGEN SENSOR (HEATER RESISTANCE) |
Inspect the heated oxygen sensor (Click here).
|
|
||||
| OK | |
| 2. CHECK TERMINAL VOLTAGE (+B OF HEATED OXYGEN SENSOR) |
![]() ![]() |
Disconnect the heated oxygen sensor connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Switch Condition
Specified Condition
D34-2 (+B) - Body ground
Ignition switch ON
11 to 14 V
Text in Illustration *a
Front view of wire harness connector
(to Heated Oxygen Sensor)
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - ECM) |
Disconnect the heated oxygen sensor connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
D34-1 (HT1A) - D97-104 (HA1A)
Always
Below 1 Ω
D34-1 (HT1A) or D97-104 (HA1A) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | |
| 4. CHECK WHETHER DTC OUTPUT RECURS |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Clear the DTCs (Click here).
Turn the ignition switch off and wait for at least 30 seconds.
Turn the ignition switch to ON.
Wait 5 seconds or more.
Read the DTCs.
Result Result
Proceed to
No DTC is output
A
DTC P0135 is output
B
|
|
||||
| A | ||
| ||
| 5. CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - NO. 1 INTEGRATION RELAY) |
Disconnect the heated oxygen sensor connector.
Remove the No. 1 integration relay from the No. 1 engine room relay block.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
D34-2 (+B) - 10A-8
Always
Below 1 Ω
D34-2 (+B) or 10A-8 - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | ||
| ||