2014-2019 Hiace · Service Manual BODY

Slide Door Handle Switch RH Circuit

Circuit diagnosis · Vehicles built from Oct 2014

DESCRIPTION

When the door control relay assembly receives a switch signal from the slide door lock remote control assembly RH (position switch), the door control relay assembly restricts operation of the power slide door.

WIRING DIAGRAM

(Click here)

INSPECTION PROCEDURE


1. INSPECT SLIDE DOOR LOCK REMOTE CONTROL ASSEMBLY RH
  1. Remove the slide door lock remote control assembly RH (Click here).

  1. B263248
    Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 3
    Handle in initial position
    10 kΩ or higher
    2 - 3
    1 - 3
    Handle pulled
    Below 1 Ω
    2 - 3



NG
REPLACE SLIDE DOOR LOCK REMOTE CONTROL ASSEMBLY RH (Click here)
OK


2. INSPECT SLIDE DOOR LOCK REMOTE CONTROL ASSEMBLY RH

  1. B163012E03
    Remove the slide door lock remote control assembly RH (Click here).

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 4
    Lock
    10 kΩ or higher
    1 - 4
    Unlock
    Below 1 Ω



NG
REPLACE SLIDE DOOR LOCK REMOTE CONTROL ASSEMBLY RH (Click here)
OK


3. INSPECT REAR DOOR WIRE RH

  1. B365974E01
    Disconnect the ci1 and fc1 rear door wire RH connectors.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A-8 - B-11
    Always
    Below 1 Ω
    A-12 - B-17
    Always
    Below 1 Ω
    A-9 - B-4
    Always
    Below 1 Ω
    A-10 - B-16
    Always
    Below 1 Ω

    Text in Illustration 
    *a
    Rear Door Wire RH
    (Door Control Relay Assembly Side)
    *b
    Rear Door Wire RH
    (Slide Door Lock Remote Control Assembly RH Side)



NG
REPLACE REAR DOOR WIRE RH (Click here)
OK


4. CHECK HARNESS AND CONNECTOR (DOOR CONTROL RELAY ASSEMBLY - SLIDE DOOR LOCK REMOTE CONTROL ASSEMBLY RH)
  1. Disconnect the I4 door control relay assembly connector.

  1. Disconnect the f4 and f5 slide door lock remote control assembly RH connectors.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    I4-8 (MPX1) - f4-1
    Always
    Below 1 Ω
    I4-20 (MPX2) - f4-2
    Always
    Below 1 Ω
    I4-13 (OSG) - f4-3
    Always
    Below 1 Ω
    I4-22 (DLSW) - f5-4
    Always
    Below 1 Ω
    I4-13 (OSG) - f5-1
    Always
    Below 1 Ω
    I4-8 (MPX1) or f4-1 - Body ground
    Always
    10 kΩ or higher
    I4-20 (MPX2) or f4-2 - Body ground
    Always
    10 kΩ or higher
    I4-13 (OSG) or f4-3 - Body ground
    Always
    10 kΩ or higher
    I4-22 (DLSW) or f5-4 - Body ground
    Always
    10 kΩ or higher
    I4-13 (OSG) or f5-1 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE DOOR CONTROL RELAY ASSEMBLY (Click here)


← Slide Door Handle Switch LH Circuit (from Oct 2014)Power Slide Door LH does not Operate When Satellite Switch is Pressed (Oct 2014 – Dec 2016) →