U010E Lost Communication with Reductant Control Module
Diagnostic trouble codes · Vehicles built from Jan 2017
DESCRIPTION
The ECM sends and receives data to and from the urea pump control ECU via local CAN communication.| DTC Detection Drive Pattern |
DTC Detection Condition |
Trouble Area |
| 1.6 seconds or more after turning the ignition switch to ON. |
Communication stops between the ECM and the urea pump control ECU for 1.6 seconds or more. |
|
MONITOR DESCRIPTION
The ECM stores a DTC when a communication malfunction occurs between the ECM and urea pump control ECU.WIRING DIAGRAM


INSPECTION PROCEDURE
- NOTICE:
- Inspect the fuses of circuits related to this system before performing the following inspection procedure.
- HINT:
- Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.
| 1. CHECK DTC OUTPUT |
Connect the GTS to the DLC3.
Turn the ignition switch to ON and turn the GTS on.
According to the display on the GTS, select "Health Check".
Check for currently output system DTCs.
- Result:
Result
Proceed to
DTC U010E is output
A
DTC U010E and other DTCs are output*
B
- HINT:
- *: If any other DTCs are output, perform troubleshooting for those DTCs first.
|
|
||||
| A | |
| 2. CHECK HARNESS AND CONNECTOR (UREA PUMP CONTROL ECU - ECM) |
Disconnect the urea pump control ECU connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
A45-27 (CAN+) - B97-41 (CANU)
Always
Below 1 Ω
A45-26 (CAN-) - B97-56 (CAND)
Always
Below 1 Ω
A45-27 (CAN+) or B97-41 (CANU) - Body ground and other terminals
Always
10 kΩ or higher
A45-26 (CAN-) or B97-56 (CAND) - Body ground and other terminals
Always
10 kΩ or higher
|
|
||||
| OK | |
| 3. CHECK UREA PUMP CONTROL ECU (BATT TERMINAL) |
Disconnect the urea pump control ECU connector.

Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Switch Condition
Specified Condition
A45-30 (BATT) - Body ground
Always
11 to 14 V
Text in Illustration *a
Front view of wire harness connector
(to Urea Pump Control ECU)
|
|
||||
| OK | |
| 4. CHECK DCU RELAY |
Inspect the DCU relay (Click here).
|
|
||||
| OK | |
| 5. CHECK UREA PUMP CONTROL ECU (UREL TERMINAL) |
Remove the DCU relay from the instrument panel relay block.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Condition
Specified Condition
DCU relay terminal 1 - Body ground
Ignition switch ON
11 to 14 V
|
|
||||
| OK | |
| 6. CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL RELAY BLOCK - UREA PUMP CONTROL ECU) |
Remove the DCU relay from the instrument panel relay block.
Disconnect the urea pump control ECU connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
DCU relay terminal 3 - A45-11 (+BSU1)
Always
Below 1 Ω
DCU relay terminal 3 - A45-10 (+BSU2)
Always
Below 1 Ω
DCU relay terminal 3 - A45-19 (+BSU3)
Always
Below 1 Ω
DCU relay terminal 3 - A45-1 (+BSU4)
Always
Below 1 Ω
DCU relay terminal 3 - A45-2 (+BSU5)
Always
Below 1 Ω
DCU relay terminal 2 - Body ground
Always
Below 1 Ω
DCU relay terminal 3 or A45-11 (+BSU1) - Body ground and other terminals
Always
10 kΩ or higher
DCU relay terminal 3 or A45-10 (+BSU2) - Body ground and other terminals
Always
10 kΩ or higher
DCU relay terminal 3 or A45-19 (+BSU3) - Body ground and other terminals
Always
10 kΩ or higher
DCU relay terminal 3 or A45-1 (+BSU4) - Body ground and other terminals
Always
10 kΩ or higher
DCU relay terminal 3 or A45-2 (+BSU5) - Body ground and other terminals
Always
10 kΩ or higher
|
|
||||
| OK | ||
| ||
| 7. CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL RELAY BLOCK - UREA PUMP CONTROL ECU) |
Remove the DCU relay from the instrument panel relay block.
Disconnect the urea pump control ECU connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
DCU relay terminal 1- A45-9 (UREL)
Always
Below 1 Ω
DCU relay terminal 1 or A45-9 (UREL) - Body ground and other terminals
Always
10 kΩ or higher
|
|
||||
| OK | ||
| ||