2007-2013 Highlander Kluger · Service Manual ENGINE

P0136 Oxygen Sensor Circuit Malfunction (Bank 1 Sensor 2)

Diagnostic trouble codes · Vehicles built from Jul 2010

Also covers:

Versions by build date: May 2007 – Jul 2008 Aug 2008 – Jun 2010 from Jul 2010

DESCRIPTION

HINT:
Sensor 2 refers to the sensor mounted behind the three-way catalytic converter and located far from the engine assembly.

In order to obtain a high purification rate of the carbon monoxide (CO), hydrocarbon (HC) and nitrogen oxide (NOx) components in the exhaust gas, a three-way catalytic converter is used. For the most efficient use of the three-way catalytic converter, the air fuel ratio must be precisely controlled so that it is always close to the stoichiometric air fuel level. For the purpose of helping the ECM to deliver accurate air fuel ratio control, a heated oxygen sensor is used.
The heated oxygen sensor is located behind the three-way catalytic converter, and detects the oxygen concentration in the exhaust gas. Since the sensor is integrated with the heater that heats the sensing portion, it is possible to detect the oxygen concentration even when the intake air volume is low (the exhaust gas temperature is low).
When the air fuel ratio becomes lean, the oxygen concentration in the exhaust gas is rich. The heated oxygen sensor informs the ECM that the post-three-way catalytic converter air fuel ratio is lean (low voltage, i.e. less than 0.45 V).
Conversely, when the air fuel ratio is richer than the stoichiometric air fuel level, the oxygen concentration in the exhaust gas becomes lean. The heated oxygen sensor informs the ECM that the post-three-way catalytic converter air fuel ratio is rich (high voltage, i.e. more than 0.45 V). The heated oxygen sensor has the property of changing its output voltage drastically when the air fuel ratio is close to the stoichiometric level.
The ECM uses the supplementary information from the heated oxygen sensor to determine whether the air fuel ratio after the three-way catalytic converter is rich or lean, and adjusts the fuel injection time accordingly. Thus, if the heated oxygen sensor is working improperly due to internal malfunctions, the ECM is unable to compensate for deviations in the primary air fuel ratio control.
A165054E01
DTC No.
DTC Detection Condition
Trouble Area
P0136
P0156
  1. Abnormal voltage output:
    1. During active air fuel ratio control, following conditions (a) and (b) met for certain period of time (2 trip detection logic)
    2. (a) Heated oxygen sensor voltage does not decrease to less than 0.21 V
    3. (b) Heated oxygen sensor voltage does not increase to more than 0.59 V
  1. Open or short in heated oxygen sensor (bank 1, 2 sensor 2)
  2. Heated oxygen sensor (bank 1, 2 sensor 2)
  3. Heated oxygen sensor heater (bank 1, 2 sensor 2)
  4. Air fuel ratio sensor (bank 1, 2 sensor 1)
  5. Gas leaks from exhaust system
P0137
P0157
  1. Low voltage (open):
    1. During active air fuel ratio control, following conditions (a) and (b) met for certain period of time (2 trip detection logic)
    2. (a) Heated oxygen sensor voltage output less than 0.21 V
    3. (b) Target air fuel ratio rich
  1. Open in heated oxygen sensor (bank 1, 2 sensor 2) circuit
  2. Heated oxygen sensor (bank 1, 2 sensor 2)
  3. Heated oxygen sensor heater (bank 1, 2 sensor 2)
  4. Air fuel ratio sensor (bank 1, 2 sensor 1)
  5. Gas leaks from exhaust system
P0138
P0158
  1. High voltage (short):
    1. During active air fuel ratio control, following conditions (a) and (b) met for certain period of time (2 trip detection logic)
    2. (a) Heated oxygen sensor voltage output more than 0.59 V
    3. (b) Target air fuel ratio lean
  1. Short in heated oxygen sensor (bank 1, 2 sensor 2) circuit
  2. Heated oxygen sensor (bank 1, 2 sensor 2)
  3. Air fuel ratio sensor (bank 1, 2 sensor 1)
  4. ECM

CONFIRMATION DRIVING PATTERN

A199376E67
  1. Connect the intelligent tester to the DLC3.
  2. Turn the ignition switch on (IG) and turn the tester on.
  3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure) (Click here).
  4. Turn the ignition switch off and wait for 30 seconds.
  5. Turn the ignition switch on (IG) and turn the tester on [A].
  6. Start the engine and warm it up until the engine coolant temperature reaches 75°C (167°F) or higher [B].
  7. With the transmission in 4th gear or higher, drive the vehicle at 60 to 120 km/h (37 to 75 mph) for 10 minutes or more [C].

    CAUTION:
    When performing the confirmation driving pattern, obey all speed limits and traffic laws.

  8. Enter the following menus: Powertrain / Engine and ECT / DTC / Pending.
  9. Read the pending DTC [D].

    HINT:
    1. If a pending DTC is output, the system is malfunctioning.
    2. If a pending DTC is not output, perform the following procedure.

  10. Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.
  11. Input the DTC: P0136, P0137, P0138, P0156, P0157 or P0158.
  12. Check the DTC judgment result.
    Tester Display
    Description
    NORMAL
    1. DTC judgment completed
    2. System normal
    ABNORMAL
    1. DTC judgment completed
    2. System abnormal
    INCOMPLETE
    1. DTC judgment not completed
    2. Perform driving pattern after confirming DTC enabling conditions
    UNKNOWN
    1. Unable to perform DTC judgment
    2. Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit

    HINT:
    1. If the judgment result shows ABNORMAL, the system has a malfunction.
    2. If the judgment result shows NORMAL, the system is normal.
    3. If the judgment result shows INCOMPLETE or UNKNOWN, perform step [C] again.

  13. Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.
  14. Check the DTC judgment result.

    HINT:
    1. If the judgment result shows ABNORMAL, the system has a malfunction.
    2. If the judgment result shows NORMAL, the system is normal.


WIRING DIAGRAM

A241530E01

INSPECTION PROCEDURE

HINT:
Malfunctioning areas can be identified by performing the Control the Injection Volume for A/F Sensor function provided in the Active Test. The Control the Injection Volume for A/F Sensor function can help to determine whether the air fuel ratio sensor, heated oxygen sensor and other potential trouble areas are malfunctioning.
The following instructions describe how to conduct the Control the Injection Volume for A/F Sensor operation using the intelligent tester.
  1. Connect the intelligent tester to the DLC3.
  2. Start the engine.
  3. Turn the tester on.
  4. Warm up the engine at an engine speed of 2500 rpm for approximately 90 seconds.
  5. Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor.
  6. Perform the Active Test operation with the engine in an idling condition (press the RIGHT or LEFT button to change the fuel injection volume).
  7. Monitor the output voltages of the air fuel ratio and heated oxygen sensors (AFS Voltage B1S1 or AFS Voltage B2S1 and O2S B1S2 or O2S B2S2) displayed on the intelligent tester.

HINT:
  1. The Control the Injection Volume for A/F Sensor operation lowers the fuel injection volume by 12.5% or increases the injection volume by 25%.
  2. Each sensor reacts in accordance with increases and decreases in the fuel injection volume.

Tester Display
Injection Volume
Status
Voltage
AFS Voltage B1S1 or AFS Voltage B2S1
(Air fuel ratio sensor)
+25%
Rich
Less than 3.1 V
-12.5%
Lean
More than 3.4 V
O2S B1S2 or O2S B2S2
(Heated oxygen sensor)
+25%
Rich
More than 0.55 V
-12.5%
Lean
Less than 0.4 V

NOTICE:
The air fuel ratio sensor has an output delay of a few seconds and the heated oxygen sensor has a maximum output delay of approximately 20 seconds.

Case
Air Fuel Ratio Sensor (Sensor 1)
Output Voltage
Heated Oxygen Sensor (Sensor 2)
Output Voltage
Main Suspected Trouble Area
1
A162605E08
A222783E01
-
2
A162596E03
A222783E01
  1. Air fuel ratio sensor
  2. Air fuel ratio sensor heater
  3. Air fuel ratio sensor circuit
3
A162605E08
A162596E03
  1. Heated oxygen sensor
  2. Heated oxygen sensor heater
  3. Heated oxygen sensor circuit
4
A162596E03
A162596E03
  1. Fuel pressure
  2. Gas leakage from exhaust system
    (Air fuel ratio extremely lean or rich)
  1. Following the Control the Injection Volume for A/F Sensor procedure enables technicians to check and graph the voltage outputs of both the air fuel ratio and heated oxygen sensors.
  2. To display the graph, enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor / All Data / AFS Voltage B1S1 or AFS Voltage B2S1 and O2S B1S2 or O2S B2S2 then press the graph button on the Data List view.

HINT:
  1. Read freeze frame data using the intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.
  2. If the OX1B or OX2B wire from the ECM connector is short-circuited to the +B wire, DTC P0136 or P0156 may be set.
  3. Bank 1 refers to the bank that includes the No. 1 cylinder*.
    *: The No. 1 cylinder is the cylinder which is farthest from the transmission.
  4. Bank 2 refers to the bank that does not include the No. 1 cylinder.
  5. Sensor 1 refers to the sensor closet to the engine assembly.
  6. Sensor 2 refers to the sensor farthest away from the engine assembly.


1. READ DTC OUTPUT (DTC P0136, P0137, P0138, P0156, P0157 OR P0158)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch on (IG).

  1. Turn the tester on.

  1. Enter the following menus: Powertrain / Engine and ECT / DTC.

  1. Read the DTCs.

    Result:
    Result
    Proceed to
    P0138 or P0158
    A
    P0137 or P0157
    B
    P0136 or P0156
    C
    P0136, P0137, P0138, P0156, P0157 or P0158 and other DTCs are output
    D



B
Go to step 9

C
Go to step 7

D
GO TO DTC CHART (Click here)
A


2. READ VALUE USING INTELLIGENT TESTER (OUTPUT VOLTAGE OF HEATED OXYGEN SENSOR)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch on (IG).

  1. Turn the tester on.

  1. Enter the following menus: Powertrain / Engine and ECT / Data List / All Data / O2S B1S2 or O2S B2S2.

  1. Start the engine and allow the engine to idle.

  1. Read the heated oxygen sensor output voltage while idling.

    Result:
    Result
    Proceed to
    1.0 V or higher
    A
    Less than 1.0 V
    B



B
Go to step 5
A


3. INSPECT HEATED OXYGEN SENSOR (CHECK FOR SHORT)

  1. A141063E24
    Disconnect the heated oxygen sensor connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Bank 1:
    Tester Connection
    Condition
    Specified Condition
    1 (+B) - 3 (E2)
    Always
    10 kΩ or higher
    1 (+B) - 4 (OX1B)
    Bank 2:
    Tester Connection
    Condition
    Specified Condition
    2 (+B) - 4 (E2)
    Always
    10 kΩ or higher
    2 (+B) - 3 (OX2B)

Text in Illustration 
*1
Bank 1
*2
Bank 2
*a
Component without harness connected
(Heated Oxygen Sensor)
  1. Reconnect the heated oxygen sensor connector.



NG
REPLACE HEATED OXYGEN SENSOR (Click here)
OK


4. CHECK HARNESS AND CONNECTOR (CHECK FOR SHORT)
  1. Turn the ignition switch off and wait for 5 minutes or more.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Bank 1:
    Tester Connection
    Condition
    Specified Condition
    B47-12 (HT1B) - B50-2 (OX1B)
    Always
    10 kΩ or higher
    Bank 2:
    Tester Connection
    Condition
    Specified Condition
    B47-13 (HT2B) - B50-4 (OX2B)
    Always
    10 kΩ or higher

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)

5. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (CONTROL THE INJECTION VOLUME)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch on (IG).

  1. Turn the tester on.

  1. Start the engine and warm it up.

  1. Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume / All Data / AFS Voltage B1S1, AFS Voltage B2S1, O2S B1S2 and O2S B2S2.

  1. Change the fuel injection volume using the tester, and monitor the voltage output of air fuel ratio and heated oxygen sensors displayed on the tester.

    HINT:
    1. Change the fuel injection volume within the range of -12% and +12%. The injection volume can be changed in fine graduations within the range.
    2. The air fuel ratio sensor is displayed as AFS Voltage B1S1 or AFS Voltage B2S1, and the heated oxygen sensor is displayed as O2S B1S2 or O2S B2S2 on the tester.
    3. The air fuel ratio sensor has an output delay of a few seconds and the heated oxygen sensor has a maximum output delay of approximately 20 seconds.


    Result:
    Tester Display
    Voltage Variation
    Proceed to
    AFS Voltage B1S1 or AFS Voltage B2S1 (Air fuel ratio)
    Alternates between more and less than 3.3 V
    OK
    Remains at more than 3.3 V
    NG
    Remains at less than 3.3 V
    NG

    HINT:
    A normal heated oxygen sensor voltage (O2S B1S2 or O2S B2S2) reacts in accordance with increases and decreases in fuel injection volumes. When the air fuel ratio sensor voltage remains at either less or more than 3.3 V despite the heated oxygen sensor indicating a normal reaction, the air fuel ratio sensor is malfunctioning.

    A121606E10



NG
Go to step 15
OK


6. INSPECT AIR FUEL RATIO SENSOR

HINT:
This air fuel ratio sensor test is to check the air fuel ratio sensor current during the fuel-cut. When the sensor is normal, the sensor current will be below 3.0 mA in this test.

  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch on (IG).

  1. Turn the tester on.

  1. Clear the DTCs.

  1. Warm up the engine.

  1. Enter the following menus: Powertrain / Engine and ECT / Data List / All Data / AFS Current B1S1 and AFS Current B2S1.

  1. Drive the vehicle according to the drive pattern listed below.

    1. Drive the vehicle at 60 km/h (37 mph) or more for 10 minutes or more.

    2. Stop the vehicle.

    3. Accelerate the vehicle to 60 km/h (37 mph) or more and decelerate for 5 seconds or more. Perform this 3 times.A152792E24

  1. Read the value of the air fuel ratio sensor current while the fuel-cut operation is being performed.

    Standard current:
    Less than 3.0 mA

    HINT:
    1. To measure the air fuel ratio sensor current precisely, perform the fuel-cut operation as long as possible.
    2. If it is difficult to measure the air fuel ratio sensor current, use the snapshot function of the intelligent tester.



OK
Go to step 12

NG
Go to step 15
7. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (CONTROL THE INJECTION VOLUME)
  1. Connect the intelligent tester to the DLC3.

  1. Start the engine.

  1. Turn the tester on.

  1. Warm up the engine.

  1. Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume / All Data / O2S B1S2 or O2S B2S2.

  1. Change the fuel injection volume using the tester, monitoring the voltage output of the heated oxygen sensors displayed on the tester.

    HINT:
    1. Change the fuel injection volume within the range of -12% to +12%. The injection volume can be changed in fine gradations within this range.
    2. The heated oxygen sensor has a maximum output delay of approximately 20 seconds.

    Standard voltage:
    Fluctuates between 0.4 V or less and 0.55 V or higher.



NG
Go to step 9
OK


8. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (INJECTION VOLUME)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch on (IG).

  1. Turn the tester on.

  1. Start the engine and warm it up.

  1. Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume / AFS Voltage B1S1, AFS Voltage B2S1, O2S B1S2 and O2S B2S2.

  1. Change the fuel injection volume using the tester, and monitor the voltage output of air fuel ratio and heated oxygen sensors displayed on the tester.

    HINT:
    1. Change the fuel injection volume within the range of -12% and +12%. The injection volume can be changed in fine graduations within the range.
    2. The air fuel ratio sensor is displayed as AFS Voltage B1S1 or AFS Voltage B2S1, and the heated oxygen sensor is displayed as O2S B1S2 or O2S B2S2 on the tester.
    3. The air fuel ratio sensor has an output delay of a few seconds and the heated oxygen sensor has a maximum output delay of approximately 20 seconds.


    Result:
    Tester Display
    Voltage Variation
    Proceed to
    AFS Voltage B1S1 or AFS Voltage B2S1 (Air fuel ratio sensor)
    Alternates between more and less than 3.3 V
    OK
    Remains at more than 3.3 V
    NG
    Remains at less than 3.3 V
    NG

    HINT:
    A normal heated oxygen sensor voltage (O2S B1S2 or O2S B2S2) reacts in accordance with increases and decreases in fuel injection volumes. When the air fuel ratio sensor voltage remains at either less or more than 3.3 V despite the heated oxygen sensor indicating a normal reaction, the air fuel ratio sensor is malfunctioning.

    A121606E10



NG
Go to step 15
OK

CHECK ENGINE TO DETERMINE CAUSE OF EXTREMELY RICH OR LEAN ACTUAL AIR FUEL RATIO (Click here)

9. CHECK FOR EXHAUST GAS LEAK
  1. Check for exhaust gas leaks from the exhaust manifold sub-assembly and exhaust pipes.

    OK:
    No gas leaks.



NG
REPAIR OR REPLACE EXHAUST GAS LEAK POINT
OK


10. INSPECT HEATED OXYGEN SENSOR (HEATER RESISTANCE)

  1. A141063E23
    Disconnect the heated oxygen sensor connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Bank 1:
    Tester Connection
    Condition
    Specified Condition
    2 (HT1B) - 1 (+B)
    20°C (68°F)
    11 to 16 Ω
    2 (HT1B) - 3 (E2)
    Always
    10 kΩ or higher
    Bank 2:
    Tester Connection
    Condition
    Specified Condition
    1 (HT2B) - 2 (+B)
    20°C (68°F)
    11 to 16 Ω
    1 (HT2B) - 4 (E2)
    Always
    10 kΩ or higher

    Text in Illustration 
    *1
    Bank 1
    *2
    Bank 2
    *a
    Component without harness connected
    (Heated Oxygen Sensor)

  1. Reconnect the heated oxygen sensor connector.



NG
REPLACE HEATED OXYGEN SENSOR (Click here)
OK


11. CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - ECM)
  1. Disconnect the heated oxygen sensor connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Bank 1:
    Tester Connection
    Condition
    Specified Condition
    P1-2 (HT1B) - B47-12 (HT1B)
    Always
    Below 1 Ω
    P1-4 (OX1B) - B50-2 (OX1B)
    P1-3 (E2) - B50-1 (EX1B)
    Bank 2:
    Tester Connection
    Condition
    Specified Condition
    B38-1 (HT2B) - B47-13 (HT2B)
    Always
    Below 1 Ω
    B38-3 (OX2B) - B50-4 (OX2B)
    B38-4 (E2) - B50-3 (EX2B)


    Standard resistance (Check for short):
    Bank 1:
    Tester Connection
    Condition
    Specified Condition
    P1-2 (HT1B) or B47-12 (HT1B) - Body ground
    Always
    10 kΩ or higher
    P1-4 (OX1B) or B50-2 (OX1B) - Body ground
    Bank 2:
    Tester Connection
    Condition
    Specified Condition
    B38-1 (HT2B) or B47-13 (HT2B) - Body ground
    Always
    10 kΩ or higher
    B38-3 (OX2B) or B50-4 (OX2B) - Body ground

  1. Reconnect the heated oxygen sensor connector.

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


12. REPLACE HEATED OXYGEN SENSOR
  1. Replace the heated oxygen sensor (Click here).


NEXT


13. PERFORM CONFIRMATION DRIVING PATTERN
  1. Refer to the confirmation driving pattern for P0136, P0137, P0138, P0156, P0157 and P0158.


NEXT


14. CHECK WHETHER DTC OUTPUT RECURS (DTC P0136, P0137, P0138, P0156, P0157 OR P0158)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch on (IG).

  1. Turn the tester on.

  1. Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.

  1. Input DTC: P0136, P0137, P0138, P0156, P0157 or P0158.Check the STATUS is NORMAL. If DTC Monitor is INCOMPLETE, perform the drive pattern again but increase the vehicle speed.

    Result:
    Result
    Proceed to
    NORMAL
    (DTC is not output)
    A
    ABNORMAL
    (DTC P0136, P0137, P0138, P0156, P0157 or P0158 is output)
    B



B
REPLACE AIR FUEL RATIO SENSOR (Click here)
A

END

15. REPLACE AIR FUEL RATIO SENSOR
  1. Replace the air fuel ratio sensor (Click here).


NEXT


16. PERFORM CONFIRMATION DRIVING PATTERN
  1. Refer to the Confirmation Driving Pattern.


NEXT


17. CHECK WHETHER DTC OUTPUT RECURS (DTC P0136, P0137, P0138, P0156, P0157 OR P0158)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch on (IG).

  1. Turn the tester on.

  1. Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.

  1. Input DTCs: P0136, P0137, P0138, P0156, P0157 or P0158.Check the STATUS is NORMAL. If DTC Monitor is INCOMPLETE, perform the drive pattern again but increase the vehicle speed.

    Result:
    Result
    Proceed to
    NORMAL
    (DTC is not output)
    A
    ABNORMAL
    (DTC P0136, P0137, P0138, P0156, P0157 or P0158 is output)
    B



B
REPLACE HEATED OXYGEN SENSOR (Click here)
A

END