The skid control ECU is connected to the combination meter via CAN communication. If any of the following is detected, the brake warning light remains on:
The skid control ECU connector is disconnected from the skid control ECU.
The brake fluid level is insufficient.
The parking brake is applied.
EBD operation has been disabled.
HINT:
For vehicles with the multi-information display, the master caution indicator light will come on and a brake malfunction message will be displayed on the multi-information display if the EBD system is malfunctioning.
WIRING DIAGRAM
INSPECTION PROCEDURE
NOTICE:
When replacing the brake actuator assembly, perform zero point calibration (Click here).
1. CHECK CAN COMMUNICATION SYSTEM
Check if a CAN communication system DTC is output (Click here).
8. CHECK HARNESS AND CONNECTOR (COMBINATION METER - BRAKE FLUID LEVEL WARNING SWITCH)
Disconnect the combination meter connector.
Measure the resistance according to the value(s) in the table below.
Standard resistance:
Tester Connection
Condition
Specified Condition
E1-28 (B/LE) - A22-1 (+)
Always
Below 1 Ω
E1-28 (B/LE) - Body ground
Always
10 kΩ or higher
A22-2 (E) - Body ground
Always
Below 1 Ω
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
9. INSPECT COMBINATION METER ASSEMBLY
Perform the Active Test of the combination meter (meter CPU) using the intelligent tester (Click here).
Check the combination meter.
HINT:
Reinstall the connectors and restore the vehicle to its prior condition before checking the combination meter.
OK:
The brake warning light turns on or off in accordance with the intelligent tester operation.
HINT:
If troubleshooting has been carried out according to the Problem Symptoms Table, refer back to the table and proceed to the next step before replacing the part (Click here).
11. CHECK HARNESS AND CONNECTOR (SKID CONTROL ECU - PARKING BRAKE SWITCH)
Disconnect the skid control ECU connector.
Measure the resistance according to the value(s) in the table below.
Standard resistance:
Tester Connection
Condition
Specified Condition
A24-29 (PKB) - A18-1
Always
Below 1 Ω
A24-29 (PKB) - Body ground
Always
10 kΩ or higher
HINT:
If troubleshooting has been carried out according to the Problem Symptoms Table, refer back to the table and proceed to the next step before replacing the part (Click here).