P0365 Camshaft Position Sensor "B" Circuit (Bank 1)
Diagnostic trouble codes · Vehicles built Jul 2010 – Jul 2013
Also covers:
- P0367 Camshaft Position Sensor "B" Circuit Low Input (Bank 1)
- P0368 Camshaft Position Sensor "B" Circuit High Input (Bank 1)
- P0390 Camshaft Position Sensor "B" Circuit (Bank 2)
- P0392 Camshaft Position Sensor "B" Circuit Low Input (Bank 2)
- P0393 Camshaft Position Sensor "B" Circuit High Input (Bank 2)
Versions by build date: May 2007 – Jun 2010 Jul 2010 – Jul 2013 from Aug 2013
DESCRIPTION
The exhaust camshaft's VVT sensor consists of a magnet and magnetic resistance element.The exhaust camshaft has a sensor plate with 3 teeth on its outer circumference.
When the exhaust camshaft rotates, changes occur in the air gaps between the 3 teeth and magneto resistance element, which affects the magnet. As a result, the resistance of the magneto resistance element material fluctuates. The VVT sensor converts the exhaust camshaft rotation data to pulse signals, uses the pulse signals to determine the camshaft angle, and sends it to the ECM.
| DTC No. |
DTC Detection Condition |
Trouble Area |
| P0365 P0390 |
Missing exhaust VVT sensor signal for 5 seconds at engine speed of 600 rpm or more (1 trip detection logic) |
|
| P0367 P0392 |
Output voltage of VVT sensor is less than 0.3 V for 4 seconds (1 trip detection logic) |
|
| P0368 P0393 |
Output voltage of VVT sensor is more than 4.7 V for 4 seconds (1 trip detection logic) |
|
WIRING DIAGRAM
Refer to DTC P0335 (Click here).INSPECTION PROCEDURE
- HINT:
- Bank 1 refers to the bank that includes the No. 1 cylinder*.
*: The No. 1 cylinder is the cylinder which is farthest from the transmission.
- Bank 2 refers to the bank that does not include the No. 1 cylinder.
- Read freeze frame data using the intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air-fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.
- Bank 1 refers to the bank that includes the No. 1 cylinder*.
| 1. CHECK VVT SENSOR FOR EXHAUST CAMSHAFT (SENSOR POWER SOURCE) |
Disconnect the VVT sensor for exhaust camshaft connector.

Turn the ignition switch on (IG).
Measure the voltage according to the value(s) in the table below.
- Standard voltage:
- Bank 1:
Tester Connection
Switch Condition
Specified Condition
B42-3 (VC2) - Body ground
Ignition switch on (IG)
4.5 to 5.0 V
- Bank 2:
Tester Connection
Switch Condition
Specified Condition
B41-3 (VC2) - Body ground
Ignition switch on (IG)
4.5 to 5.0 V
Text in Illustration *1
Bank 1
*2
Bank 2
*a
Front view of wire harness connector
(to VVT Sensor for Exhaust Camshaft)
Reconnect the VVT sensor connector.
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (VVT SENSOR - ECM) |
Disconnect the VVT sensor for exhaust camshaft connector.
Disconnect the ECM connector.
Measure the resistance between the wire harness side connectors.
- Standard resistance (Check for open):
- Bank 1:
Tester Connection
Condition
Specified Condition
B42-1 (EX+) - B50-13 (EV1+)
Always
Below 1 Ω
B42-2 (EX-) - B50-14 (EV1-)
Always
Below 1 Ω
- Bank 2:
Tester Connection
Condition
Specified Condition
B41-1 (EX+) - B50-18 (EV2+)
Always
Below 1 Ω
B41-2 (EX-) - B50-17 (EV2-)
Always
Below 1 Ω
- Standard resistance (Check for short):
- Bank 1:
Tester Connection
Condition
Specified Condition
B42-1 (EX+) or B50-13 (EV1+) - Body ground
Always
10 kΩ or higher
B42-2 (EX-) or B50-14 (EV1-) - Body ground
Always
10 kΩ or higher
- Bank 2:
Tester Connection
Condition
Specified Condition
B41-1 (EX+) or B50-18 (EV2+) - Body ground
Always
10 kΩ or higher
B41-2 (EX-) or B50-17 (EV2-) - Body ground
Always
10 kΩ or higher
Reconnect the VVT sensor connector.
Reconnect the ECM connector.
|
|
||||
| OK | |
| 3. CHECK VVT SENSOR FOR EXHAUST CAMSHAFT (SENSOR INSTALLATION) |
Check the VVT sensor installation.

- OK:
- Sensor is installed correctly.
|
|
||||
| OK | |
| 4. CHECK EXHAUST CAMSHAFT (TIMING ROTOR) |
Check the timing rotor of the camshaft.
- OK:
- Timing rotor does not have any cracks or deformation.
|
|
||||
| OK | |
| 5. REPLACE VVT SENSOR (FOR EXHAUST CAMSHAFT) |
Replace the VVT sensor for exhaust camshaft (Click here).
| NEXT | |
| 6. CHECK WHETHER DTC OUTPUT RECURS |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG).
Turn the tester on.
Clear the DTCs.
Turn the ignition switch off.
Turn the ignition switch on (IG) and turn the tester on.
Start the engine.
Idle the engine for 10 seconds or more.
Enter the following menus: Powertrain / Engine and ECT / DTC.
Read the DTCs.
- Result:
Display (DTC Output)
Proceed to
No output
A
P0365, P0367, P0368, P0390, P0392 or P0393
B
- HINT:
- If the engine does not start, replace the ECM.
|
|
||||
| A | ||
| ||
| 7. CHECK HARNESS AND CONNECTOR (VVT SENSOR - ECM) |
Disconnect the VVT sensor for exhaust camshaft connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard resistance (Check for open):
- Bank 1:
Tester Connection
Condition
Specified Condition
B42-3 (VC2) - B50-15 (VCV1)
Always
Below 1 Ω
- Bank 2:
Tester Connection
Condition
Specified Condition
B41-3 (VC2) - B50-15 (VCV1)
Always
Below 1 Ω
- Standard resistance (Check for short):
- Bank 1:
Tester Connection
Condition
Specified Condition
B42-3 (VC2) or B50-15 (VCV1) - Body ground
Always
10 kΩ or higher
- Bank 2:
Tester Connection
Condition
Specified Condition
B41-3 (VC2) or B50-15 (VCV1) - Body ground
Always
10 kΩ or higher
Reconnect the VVT sensor connector.
Reconnect the ECM connector.
|
|
||||
| OK | ||
| ||