2007-2013 Highlander Kluger · Service Manual ENGINE

P0365 Camshaft Position Sensor "B" Circuit (Bank 1)

Diagnostic trouble codes · Vehicles built from Aug 2013

Also covers:

Versions by build date: May 2007 – Jun 2010 Jul 2010 – Jul 2013 from Aug 2013

DESCRIPTION

The exhaust camshaft's VVT sensor consists of a magnet and magnetic resistance element.
The exhaust camshaft has a sensor plate with 3 teeth on its outer circumference.
When the exhaust camshaft rotates, changes occur in the air gaps between the 3 teeth and magneto resistance element, which affects the magnet. As a result, the resistance of the magneto resistance element material fluctuates. The VVT sensor converts the exhaust camshaft rotation data to pulse signals, uses the pulse signals to determine the camshaft angle, and sends it to the ECM.
DTC No.
DTC Detection Condition
Trouble Area
P0365
P0390
Missing exhaust VVT sensor signal for 5 seconds at engine speed of 600 rpm or more (1 trip detection logic)
  1. Open or short in VVT sensor for exhaust camshaft circuit
  2. VVT sensor for exhaust camshaft
  3. Exhaust camshaft
  4. Jumped tooth of timing chain
  5. ECM
P0367
P0392
Output voltage of VVT sensor is less than 0.3 V for 4 seconds
(1 trip detection logic)
  1. Open or short in VVT sensor for exhaust camshaft circuit
  2. VVT sensor for exhaust camshaft
  3. Exhaust camshaft
  4. Jumped tooth of timing chain
  5. ECM
P0368
P0393
Output voltage of VVT sensor is more than 4.7 V for 4 seconds
(1 trip detection logic)
  1. Open or short in VVT sensor for exhaust camshaft circuit
  2. VVT sensor for exhaust camshaft
  3. Exhaust camshaft
  4. Jumped tooth of timing chain
  5. ECM

WIRING DIAGRAM

Refer to DTC P0335 (Click here).

INSPECTION PROCEDURE

HINT:
  1. Bank 1 refers to the bank that includes the No. 1 cylinder*.
    *: The No. 1 cylinder is the cylinder which is farthest from the transmission.
  2. Bank 2 refers to the bank that does not include the No. 1 cylinder.
  3. Read freeze frame data using the intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air-fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.


1. CHECK VVT SENSOR FOR EXHAUST CAMSHAFT (SENSOR POWER SOURCE)

  1. A168210E17
    Disconnect the VVT sensor for exhaust camshaft connector.

  1. Turn the ignition switch on (IG).

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Bank 1:
    Tester Connection
    Switch Condition
    Specified Condition
    B42-3 (VC2) - Body ground
    Ignition switch on (IG)
    4.5 to 5.0 V
    Bank 2:
    Tester Connection
    Switch Condition
    Specified Condition
    B41-3 (VC2) - Body ground
    Ignition switch on (IG)
    4.5 to 5.0 V

    Text in Illustration 
    *1
    Bank 1
    *2
    Bank 2
    *a
    Front view of wire harness connector
    (to VVT Sensor for Exhaust Camshaft)

  1. Reconnect the VVT sensor connector.



NG
Go to step 7
OK


2. CHECK HARNESS AND CONNECTOR (VVT SENSOR - ECM)
  1. Disconnect the VVT sensor for exhaust camshaft connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance between the wire harness side connectors.

    Standard resistance (Check for open):
    Bank 1:
    Tester Connection
    Condition
    Specified Condition
    B42-1 (EX+) - B50-13 (EV1+)
    Always
    Below 1 Ω
    B42-2 (EX-) - B50-14 (EV1-)
    Always
    Below 1 Ω
    Bank 2:
    Tester Connection
    Condition
    Specified Condition
    B41-1 (EX+) - B50-18 (EV2+)
    Always
    Below 1 Ω
    B41-2 (EX-) - B50-17 (EV2-)
    Always
    Below 1 Ω


    Standard resistance (Check for short):
    Bank 1:
    Tester Connection
    Condition
    Specified Condition
    B42-1 (EX+) or B50-13 (EV1+) - Body ground
    Always
    10 kΩ or higher
    B42-2 (EX-) or B50-14 (EV1-) - Body ground
    Always
    10 kΩ or higher
    Bank 2:
    Tester Connection
    Condition
    Specified Condition
    B41-1 (EX+) or B50-18 (EV2+) - Body ground
    Always
    10 kΩ or higher
    B41-2 (EX-) or B50-17 (EV2-) - Body ground
    Always
    10 kΩ or higher

  1. Reconnect the VVT sensor connector.

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (VVT SENSOR - ECM)
OK


3. CHECK VVT SENSOR FOR EXHAUST CAMSHAFT (SENSOR INSTALLATION)

  1. BR03795E18
    Check the VVT sensor installation.

    OK:
    Sensor is installed correctly.



NG
REPAIR OR REPLACE VVT SENSOR (Click here)
OK


4. CHECK EXHAUST CAMSHAFT (TIMING ROTOR)
  1. Check the timing rotor of the camshaft.

    OK:
    Timing rotor does not have any cracks or deformation.



NG
REPLACE EXHAUST CAMSHAFT (Click here)
OK


5. REPLACE VVT SENSOR (FOR EXHAUST CAMSHAFT)
  1. Replace the VVT sensor for exhaust camshaft (Click here).


NEXT


6. CHECK WHETHER DTC OUTPUT RECURS
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch on (IG).

  1. Turn the tester on.

  1. Clear the DTCs.

  1. Turn the ignition switch off.

  1. Turn the ignition switch on (IG) and turn the tester on.

  1. Start the engine.

  1. Idle the engine for 10 seconds or more.

  1. Enter the following menus: Powertrain / Engine and ECT / DTC.

  1. Read the DTCs.

    Result:
    Display (DTC Output)
    Proceed to
    No output
    A
    P0365, P0367, P0368, P0390, P0392 or P0393
    B

    HINT:
    If the engine does not start, replace the ECM.



B
REPLACE ECM (Click here)
A

END

7. CHECK HARNESS AND CONNECTOR (VVT SENSOR - ECM)
  1. Disconnect the VVT sensor for exhaust camshaft connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Bank 1:
    Tester Connection
    Condition
    Specified Condition
    B42-3 (VC2) - B50-15 (VCV1)
    Always
    Below 1 Ω
    Bank 2:
    Tester Connection
    Condition
    Specified Condition
    B41-3 (VC2) - B50-15 (VCV1)
    Always
    Below 1 Ω


    Standard resistance (Check for short):
    Bank 1:
    Tester Connection
    Condition
    Specified Condition
    B42-3 (VC2) or B50-15 (VCV1) - Body ground
    Always
    10 kΩ or higher
    Bank 2:
    Tester Connection
    Condition
    Specified Condition
    B41-3 (VC2) or B50-15 (VCV1) - Body ground
    Always
    10 kΩ or higher

  1. Reconnect the VVT sensor connector.

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (VVT SENSOR - ECM)
OK

REPLACE ECM (Click here)


← P0365 Camshaft Position Sensor "B" Circuit (Bank 1) (+ 5 more codes) (Jul 2010 – Jul 2013)P0420 Catalyst System Efficiency Below Threshold (Bank 1) (+ P0430) (May 2007 – Jul 2008) →