2007-2013 Highlander Kluger · Service Manual ENGINE

ECM Power Source Circuit

Circuit diagnosis · Vehicles built May 2007 – Jul 2008

Versions by build date: May 2007 – Jul 2008 Aug 2008 – Jun 2010 from Jul 2010

DESCRIPTION

When the ignition switch is turned on (IG), the battery voltage is applied to terminal IGSW of the ECM. The ECM MREL output signal causes a current to flow to the coil, closing the contacts of the EFI relay and supplying power to terminal +B and +B2 of the ECM.
If the ignition switch is turned off, the ECM holds the EFI relay ON for a maximum of 2 seconds to allow for the initial setting of the throttle valve.

WIRING DIAGRAM

A173972E04
A173973E03

INSPECTION PROCEDURE


1. INSPECT ECM (+B AND +B2 VOLTAGE)

  1. A168199E17
    Turn the ignition switch on (IG).

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    D31-1 (+B) - B3-1 (E1)
    Ignition switch on (IG)
    9 to 14 V
    D31-2 (+B2) - B3-1 (E1)
    Ignition switch on (IG)
    9 to 14 V



NG
Go to step 2
OK

PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

2. CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND)

  1. A172715E01
    Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Check for open:
    Tester Connection
    Condition
    Specified Condition
    B3-1 (E1) - Body ground
    Always
    Below 1 Ω

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (ECM - BODY GROUND)
OK


3. INSPECT ECM (MREL VOLTAGE)

  1. A168199E18
    Turn the ignition switch on (IG).

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    D31-8 (MREL) - B3-1 (E1)
    Ignition switch on (IG)
    9 to 14 V



NG
Go to step 8
OK


4. CHECK FUSE (EFI MAIN AND EFI NO. 2 FUSE)

  1. A168235E10
    Remove the EFI MAIN and EFI No. 2 fuse from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    EFI MAIN fuse
    Always
    Below 1 Ω
    EFI No. 2 fuse
    Always
    Below 1 Ω

  1. Reinstall the fuses.



NG
REPLACE FUSE (EFI MAIN OR EFI NO. 2 FUSE)
OK


5. INSPECT ENGINE ROOM JUNCTION BLOCK ASSEMBLY (EFI RELAY)
  1. Inspect the EFI relay (Click here).



NG
REPLACE RELAY (EFI RELAY) (Click here)
OK


6. CHECK HARNESS AND CONNECTOR (EFI MAIN RELAY - ECM, EFI RELAY - BODY GROUND)

  1. A172717E01
    Remove the engine room junction block from the engine room relay block.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Check for open:
    Tester Connection
    Condition
    Specified Condition
    2E-9 (EFI relay terminal) - D31-8 (MREL)
    Always
    Below 1 Ω
    2E-10 (EFI relay terminal) - Body ground
    Always
    Below 1 Ω
    Check for short:
    Tester Connection
    Condition
    Specified Condition
    2E-9 (EFI relay terminal) or D31-8 (MREL) - Body ground
    Always
    10 kΩ or higher

  1. Reinstall the engine room junction block.

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


7. CHECK HARNESS AND CONNECTOR (EFI MAIN RELAY - ECM)

  1. A172717E02
    Remove the engine room junction block from the engine room relay block.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Check for open:
    Tester Connection
    Condition
    Specified Condition
    2E-6 (EFI relay terminal) - D31-1 (+B)
    Always
    Below 1 Ω
    2E-6 (EFI relay terminal) - D31-2 (+B2)
    Always
    Below 1 Ω
    Check for short:
    Tester Connection
    Condition
    Specified Condition
    2E-6 (EFI relay terminal) or D31-1 (+B) - Body ground
    Always
    10 kΩ or higher
    2E-6 (EFI relay terminal) or D31-2 (+B2) - Body ground
    Always
    10 kΩ or higher

  1. Reinstall the engine room junction block.

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (EFI MAIN RELAY - ECM)
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR (EFI MAIN RELAY - EFI MAIN FUSE)

8. INSPECT ECM (IGSW VOLTAGE)

  1. A168199E19
    Turn the ignition switch on (IG).

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    D31-9 (IGSW) - B3-1 (E1)
    Ignition switch on (IG)
    9 to 14 V



NG
Go to step 9
OK

REPLACE ECM (Click here)

9. CHECK HARNESS AND CONNECTOR (ECM - IG2 RELAY)

  1. A172718E01
    Remove the IG2 relay from the engine room relay block.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    IG2 relay terminal 3 - D31-9 (IGSW)
    Always
    Below 1 Ω

  1. Reconnect the ECM connector.

  1. Reinstall the IG2 relay.



NG
Go to step 14
OK


10. INSPECT IG2 RELAY

  1. B016200
    Remove the IG2 relay from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    When no battery voltage applied to terminals 1 and 2
    10 kΩ or higher
    When battery voltage applied to terminals 1 and 2
    Below 1 Ω

  1. Reinstall the IG2 relay.



NG
REPLACE IG2 RELAY
OK


11. CHECK HARNESS AND CONNECTOR (IG2 RELAY POWER SOURCE)

  1. A172712E01
    Remove the IG2 relay from the engine room relay block.

  1. Turn the ignition switch on (IG)

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    5 - Body ground
    Ignition switch on (IG)
    9 to 14 V

  1. Reinstall the IG2 relay.



NG
Go to step 13
OK


12. CHECK HARNESS AND CONNECTOR (IG2 RELAY - BODY GROUND)

  1. A172712E01
    Remove the IG2 relay from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    2 - Body ground
    Always
    Below 1 Ω

  1. Reinstall the IG2 relay.

    Result:
    Result
    Proceed to
    NG
    A
    OK (w/o Smart entry and star system)
    B
    OK (w/ Smart entry and star system)
    C



B
Go to step 15

C
Go to step 17
A

REPAIR OR REPLACE HARNESS OR CONNECTOR (IG2 RELAY - BODY GROUND)

13. CHECK FUSE (IG2 FUSE)

  1. A168235E08
    Remove the IG2 fuse from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    IG2 fuse
    Always
    Below 1 Ω

  1. Reinstall the IG2 fuse



NG
REPLACE FUSE (IG2 FUSE)
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR (IG2 RELAY - BATTERY)

14. CHECK FUSE (IGN FUSE)

  1. A168236E01
    Remove the IGN fuse from the instrument panel junction block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    IGN fuse
    Always
    Below 1 Ω

  1. Reinstall the IGN fuse.



NG
REPLACE FUSE (IGN FUSE)
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR (IG2 RELAY - ECM)

15. CHECK HARNESS AND CONNECTOR (IGNITION SWITCH - IG2 RELAY)

  1. A172716E01
    Remove the IG2 relay from the engine room relay block.

  1. Disconnect the ignition switch connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Check for open:
    Tester Connection
    Condition
    Specified Condition
    D21-6 (IG2) - IG2 relay terminal 1
    Always
    Below 1 Ω
    Check for short:
    Tester Connection
    Condition
    Specified Condition
    D21-6 (IG2) or IG2 relay terminal 1 - Body ground
    Always
    10 kΩ or higher

  1. Reinstall the IG2 relay.

  1. Reconnect the ignition switch connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (IGNITION SWITCH - IG2 RELAY)
OK


16. INSPECT IGNITION SWITCH
  1. Inspect the ignition or starter switch assembly (Click here).



NG
REPLACE IGNITION SWITCH (Click here)
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR (IGNITION SWITCH - BATTERY)

17. CHECK HARNESS AND CONNECTOR (IG2 RELAY - MAIN BODY ECU, IG2 RELAY - BODY GROUND)

  1. A172719E01
    Remove the IG2 relay from the engine room relay block.

  1. Remove the instrument panel junction block (main body ECU).

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Tester Connection
    Condition
    Specified Condition
    IG2 relay terminal (1) - D6-11 (IG2D)
    Always
    Below 1 Ω
    IG2 relay terminal (2) - Body ground
    Always
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Condition
    Specified Condition
    D6-11 (IG2D) - Body ground
    Always
    10 kΩ or higher

  1. Reinstall the IG2 relay.

  1. Reconnect the main body ECU connector.



NG
CHECK SMART ENTRY AND START SYSTEM (Click here)
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR


← Active Control Engine Mount System (from Jul 2010)ECM Power Source Circuit (Aug 2008 – Jun 2010) →