2007-2013 Highlander Kluger · Service Manual ENGINE

P1660 VSV for AICVS Circuit

Diagnostic trouble codes · Vehicles built May 2007 – Jun 2010

Versions by build date: May 2007 – Jun 2010 from Jul 2010

DESCRIPTION

The air cleaner is equipped with two inlets, one of which is opened or closed by the air intake control valve. This system reduces intake noise and increases engine power at low to high engine speeds range.
When the engine is operating in the low-to-mid speed range, this control operates the air intake control valve to close one of the air cleaner inlets. When the engine speed is more than 3600 rpm and the opening angle of the throttle valve is more than 60°, the ECM activates the VSV and opens the air intake control valve.
A061332E07
DTC No.
Detection Condition
Trouble Area
P1660
The following conditions are met simultaneously for 0.5 seconds or more (2 trip detection logic):
  1. Voltage of terminal ACIS of the ECM is low when the VSV is OFF
  2. The engine has been started
  1. Open or short in air intake control valve circuit
  2. Air intake control vale
  3. ECM

WIRING DIAGRAM

A136867E26

INSPECTION PROCEDURE


1. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (CONTROL THE VSV FOR AICS)

  1. A067588E07
    Turn the ignition switch on (IG) and turn the intelligent tester on.

  1. Select the following menu items: Powertrain / Engine and ECT / Active Test /Control the VSV for AICS.

  1. Check the operation of the VSV when the VSV is operated by the intelligent tester.

    OK:
    Tester Operation
    Specified Condition
    VSV is ON
    Air from port E flows out through port F
    VSV is OFF
    Air from port E flows out through the air filter



NG
Go to step 3
OK


2. INSPECT VACUUM TANK
  1. Inspect the vacuum tank (Click here).



NG
REPAIR OR REPLACE AIR CLEANER CAP
OK

REPLACE ECM (Click here)

3. CHECK VSV ASSEMBLY (FOR AIR INTAKE CONTROL VALVE)
  1. Inspect the VSV for AICV (Click here).



NG
REPLACE VACUUM SWITCHING VALVE (Click here)
OK


4. INSPECT TERMINAL VOLTAGE (VSV FOR AIR INTAKE CONTROL VALVE CONNECTOR)

  1. A168222E01
    Disconnect the VSV for air intake control valve connector.

  1. Turn the ignition switch on (IG).

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    1 - Body ground
    Ignition switch on (IG)
    9 to 14 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (EFI NO. 3 FUSE - VSV FOR AIR INTAKE CONTROL VALVE)
OK


5. CHECK HARNESS AND CONNECTOR (VSV FOR AIR INTAKE CONTROL VALVE - ECM)

  1. A168217E02
    Disconnect the VSV for air intake control valve connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Tester Connection
    Condition
    Specified Condition
    A10-2 - B1-27 (AICV)
    Always
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Condition
    Specified Condition
    A10-2 or B1-27 (AICV) - Body ground
    Always
    10 kΩ or higher

  1. Reconnect the ECM connector.

  1. Reconnect the VSV for air intake control valve connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)


← P1604 Startability Malfunction (from Aug 2013)P1660 VSV for AICVS Circuit (from Jul 2010) →