Home › TRANSMISSION · U151E AUTOMATIC TRANSAXLE › AUTOMATIC TRANSAXLE SYSTEM

DTC    P0705    Transmission Range Sensor Circuit Malfunction (PRNDL Input)

for Preparation Click here


DESCRIPTION

The park/neutral position switch detects the shift lever position and sends signals to the ECM.

DTC No.
DTC Detection Condition
Trouble Area
P0705
(A) Any 2 or more signals of the following are ON simultaneously (2-trip detection logic)
  1. P input signal is ON.
  2. N input signal is ON.
  3. R input signal is ON.
  4. D input signal is ON.
(B) Any 2 or more signals of the following are ON simultaneously (2-trip detection logic)
  1. NSW (STAR) input signal is ON.
  2. R input signal is ON.
  3. D input signal is ON.
(C) All switches are OFF simultaneously for NSW (STAR), P, R, N, D, positions (2-trip detection logic).
(D) When any of following conditions for 2 sec. or more in the S position (2-trip detection logic)
  1. NSW (STAR) input signal is ON.
  2. P input signal is ON.
  3. N input signal is ON.
  4. R input signal is ON.
  1. Open or short in park/neutral position switch circuit
  2. Park/neutral position switch
  3. ECM

MONITOR DESCRIPTION

These DTCs indicate a problem with the park/neutral position switch and the wire harness in the park/neutral position switch circuit.
The park/neutral position switch detects the shift lever position and sends a signal to the ECM.
For security, the park/neutral position switch detects the shift lever position so that engine can be started only when the shift lever is in the P or N position.
The park/neutral position switch sends a signal to the ECM according to the shift position (P, R, N or D). The ECM determines that there is a problem with the switch or related parts if in receives more than 1 position signal simultaneously. The ECM will turn on the MIL and store the DTC.

MONITOR STRATEGY


Related DTCs
P0705: Park/neutral position switch/Verify switch input
Required sensors/Components
Park/neutral position switch
Frequency of operation
Continuous
Duration
Condition (A), (B), (D)
2 sec.
Condition (C)
60 sec.
MIL operation
2 driving cycles
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


All: 
The monitor will run whenever this DTC is not present.
None
Ignition switch
ON
Battery voltage
10.5 V or more

TYPICAL MALFUNCTION THRESHOLDS


One of the following conditions are met: Condition (A), (B), (C) and (D)

Condition (A): 
Number of the following signal input at the same time
2 or more
P switch
ON
N switch
ON
R switch
ON
D switch
ON

Condition (B): 
Number of the following signal input at the same time
2 or more
NSW (STAR) switch
ON
R switch
ON
D switch
ON

Condition (C): 
NSW (STAR) switch
OFF
P switch
OFF
N switch
OFF
R switch
OFF
D switch
OFF

When shift lever is in the S position switch (M switch)
Condition (D): 
One of the following conditions are met:
-
NSW (STAR) switch
ON
P switch
ON
N switch
ON
R switch
ON

COMPONENT OPERATING RANGE


Park/neutral Position switch
The park/neutral position switch sends only one signal to the ECM.

WIRING DIAGRAM


C171921E03


C171922E05


INSPECTION PROCEDURE

1.CHECK HARNESS AND CONNECTOR (BATTERY - PARK/NEUTRAL POSITION SWITCH)


    C117645E76
  1. Disconnect the park/neutral position switch connector.

  1. Turn the ignition switch on (IG).

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    B5-2 (RB) - Body ground
    Ignition switch on (IG)
    11 to 14 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


2.CHECK HARNESS AND CONNECTOR (OUTPUT SIGNAL)


    C117645E77
  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    B5-4 (B) - Body ground
    Ignition switch on (IG)
    11 to 14 V

    Result:
    Result
    Proceed to
    OK
    A
    NG (w/o Smart Key System)
    B
    NG (w/ Smart Key System)
    C



B
Go to step 8

C
CHECK CRANKING HOLDING FUNCTION CIRCUIT (for 2GR-FE) (Click here)
A


3.INSPECT PARK/NEUTRAL POSITION SWITCH ASSEMBLY


    C110340E95
  1. Measure the resistance according to the value(s) in the table below when the shift lever is moved to each position.

    Standard resistance:
    Tester Connection
    Shift Position
    Specified Condition
    4 - 5
    P and N
    Below 1 Ω
    Except P and N
    10 kΩ or higher
    2 - 6
    P
    Below 1 Ω
    Except P
    10 kΩ or higher
    2 - 1
    R
    Below 1 Ω
    Except R
    10 kΩ or higher
    2 - 9
    N
    Below 1 Ω
    Except N
    10 kΩ or higher
    2 - 7
    D, S, "+" and "-"
    Below 1 Ω
    Except D, S, "+" and "-"
    10 kΩ or higher



NG
REPLACE PARK/NEUTRAL POSITION SWITCH ASSEMBLY (Click here)
OK


4.CHECK HARNESS AND CONNECTOR (BATTERY - SHIFT LOCK CONTROL UNIT ASSEMBLY)


    C168574E06
  1. Disconnect the transmission control switch connector of shift lock control unit assembly.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    D28-3 (IG) - Body ground
    Ignition switch on (IG)
    11 to 14 V
    Ignition switch off
    Below 1 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5.INSPECT SHIFT LOCK CONTROL UNIT ASSEMBLY


    C168599E04
  1. Measure the resistance according to the value(s) in the table below when the shift lever is moved to each position.

    Standard resistance:
    Tester Connection
    Shift Position
    Specified Condition
    3 - 7
    S, "+" and "-"
    Below 1 Ω
    Except S, "+" and "-"
    10 kΩ or higher



NG
REPLACE SHIFT LOCK CONTROL UNIT ASSEMBLY (Click here)
OK


6.CHECK HARNESS AND CONNECTOR (SHIFT LOCK CONTROL UNIT ASSEMBLY - ECM)


    C168527E10
  1. Connect the transmission control switch connector of shift lock control unit assembly.

  1. Disconnect the ECM connector.

  1. Measure the voltage according to the value(s) in the table below when the shift lever is moved to each position.

    Standard voltage:
    Tester Connection
    Shift Position
    Specified Condition
    D36-20 (S) - Body ground
    S, "+" and "-"
    11 to 14 V
    Except S, "+" and "-"
    Below 1 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


7.CHECK HARNESS AND CONNECTOR (PARK/NEUTRAL POSITION SWITCH - ECM)


    C168527E11
  1. Connect the park/neutral position switch connector.

  1. Measure the voltage according to the value(s) in the table below when the shift lever is moved to each position.

    Standard voltage:
    Tester Connection
    Shift Position
    Specified Condition
    D36-23 (P) - Body ground
    P
    11 to 14 V
    Except P
    Below 1 V
    D36-22 (N) - Body ground
    N
    11 to 14 V
    Except N
    Below 1 V
    D36-11 (R) - Body ground
    R
    11 to 14 V*
    Except R
    Below 1 V
    D36-21 (D) - Body ground
    D and S
    11 to 14 V
    Except D and S
    Below 1 V

    HINT:
    *: The voltage will drop slightly due to lighting up of the back up light.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (for 2GR-FE) (Click here)  

8.CHECK HARNESS AND CONNECTOR (PARK/NEUTRAL POSITION SWITCH - ECM)


    C169035E05
  1. Turn the ignition switch off.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Tester Connection
    Condition
    Specified Condition
    B5-4 (B) - B2-8 (STAR)
    Always
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Condition
    Specified Condition
    B5-4 (B) or B2-8 (STAR) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (for 2GR-FE) (Click here)