DTC P0A94-549 DC / DC Converter Performance |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A94 | 549 | Boost converter overvoltage signal detection (overvoltage by hybrid vehicle transaxle assembly malfunction) |
|
| Related DTCs | P0A94 (INF 549): OVL detection overvoltage |
| Required sensors / components | Boost converter |
| Frequency of operation | Continuous |
| Duration | TMC's intellectual property |
| MIL operation | Immediately |
| Sequence of operation | None |
| The monitor will run whenever the DTCs listed are not present | TMC's intellectual property |
| Boost converter | Overvoltage |
| Boost converter | DTC P0A94 (INF 549) is not detected |
| 1.CHECK DTC OUTPUT (HV) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
| P0A94-549 only is output. | A |
| Any of the following DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range / Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A45-669 | Drive Motor "B" Position Sensor Circuit |
| P0A46-671 | Drive Motor "B" Position Sensor Circuit Range / Performance |
| P0A47-670 | Drive Motor "B" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range / Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A78-266, 280 | Drive Motor "A" Inverter Performance |
| P0A94-558, 559, 588, 589 | DC / DC Converter Performance |
| P0A95-123 | High Voltage Fuse |
| P0ADB-227 | Hybrid Battery Positive Contactor Control Circuit Low |
| P0ADC-226 | Hybrid Battery Positive Contactor Control Circuit High |
| P0ADF-229 | Hybrid Battery Negative Contactor Control Circuit Low |
| P0AE0-228 | Hybrid Battery Negative Contactor Control Circuit High |
| P3004-803 | Power Cable Malfunction |
|
| ||||
| A | |
| 2.CHECK CONNECTOR CONNECTION CONDITION (MG ECU CONNECTOR) |
Turn the power switch off.
Remove the service plug grip (Click here).
Remove the inverter cover (Click here).
![]() |
Check the connections of all MG ECU connectors.
|
| ||||
| OK | |
| 3.INSPECT HV RELAY ASSEMBLY (SMR2) |
Check that the service plug grip is not installed.
Remove the HV relay assembly from the vehicle (Click here).
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| z30-1 - j2-1 | Power switch off (Auxiliary battery voltage is applied between terminals z20-1 (CON2) and z20-4 (GND)) | Below 1 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| z20-1 (CON2) - z20-4 (GND) | Power switch off (at -31 to 176°F (-35 to 80°C)) | 20 to 60 Ω |
|
| ||||
| OK | |
| 4.INSPECT HV RELAY ASSEMBLY (SMR3) |
Check that the service plug grip is not installed.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| z31-1 - j3-1 | Power switch off (Auxiliary battery voltage is applied between terminals z20-2 (CON3) and z20-4 (GND)) | Below 1 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| z20-2 (CON3) - z20-4 (GND) | Power switch off (at -31 to 176°F (-35 to 80°C)) | 20 to 60 Ω |
|
| ||||
| OK | |
| 5.CONFIRM INFORMATION (EXCLUSIVE INFORMATION 4) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
Display freeze frame data corresponding to DTC P0A94 and select the information.
Select INF code 549 and read "Exclusive Information 4".
| Displayed item in exclusive information 4 | Proceed to |
| -63 to 64 | A |
| 65 to 128 | B |
|
| ||||
| A | |
| 6.CHECK HARNESS AND CONNECTOR (MG ECU - MOTOR RESOLVER) |
Disconnect connector B49 from the MG ECU.
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B49-13 (MRF) - Body ground | Power switch on (IG) | Below 1 V |
| B49-23 (MRFG) - Body ground | Power switch on (IG) | Below 1 V |
| B49-21 (MSN) - Body ground | Power switch on (IG) | Below 1 V |
| B49-20 (MSNG) - Body ground | Power switch on (IG) | Below 1 V |
| B49-19 (MCS) - Body ground | Power switch on (IG) | Below 1 V |
| B49-18 (MCSG) - Body ground | Power switch on (IG) | Below 1 V |
Turn the power switch off.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B49-13 (MRF) - B49-23 (MRFG) | Power switch off | 7.65 to 10.2 Ω |
| B49-21 (MSN) - B49-20 (MSNG) | Power switch off | 12.6 to 16.8 Ω |
| B49-19 (MCS) - B49-18 (MCSG) | Power switch off | 12.6 to 16.8 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B49-13 (MRF) or B49-23 (MRFG) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| B49-21 (MSN) or B49-20 (MSNG) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| B49-19 (MCS) or B49-18 (MCSG) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
|
| ||||
| OK | |
| 7.CHECK HARNESS AND CONNECTOR (MG ECU - GENERATOR RESOLVER) |
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B49-12 (GRF) - Body ground | Power switch on (IG) | Below 1 V |
| B49-22 (GRFG) - Body ground | Power switch on (IG) | Below 1 V |
| B49-11 (GSN) - Body ground | Power switch on (IG) | Below 1 V |
| B49-10 (GSNG) - Body ground | Power switch on (IG) | Below 1 V |
| B49-9 (GCS) - Body ground | Power switch on (IG) | Below 1 V |
| B49-8 (GCSG) - Body ground | Power switch on (IG) | Below 1 V |
Turn the power switch off.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B49-12 (GRF) - B49-22 (GRFG) | Power switch off | 7.65 to 10.2 Ω |
| B49-11 (GSN) - B49-10 (GSNG) | Power switch off | 12.6 to 16.8 Ω |
| B49-9 (GCS) - B49-8 (GCSG) | Power switch off | 12.6 to 16.8 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B49-12 (GRF) or B49-22 (GRFG) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| B49-11 (GSN) or B49-10 (GSNG) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| B49-9 (GCS) or B49-8 (GCSG) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
|
| ||||
| OK | |
| 8.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the motor resolver connector.
|
| ||||
| OK | |
| 9.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR) |
Remove the inverter with converter assembly (Click here).
![]() |
Check the connection of the generator resolver connector.
|
| ||||
| OK | ||
| ||
| 10.CHECK HARNESS AND CONNECTOR (MG ECU - REAR MOTOR RESOLVER) |
Turn the power switch off.
Disconnect connector A42 from the MG ECU.
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A42-21 (RRF) - Body ground | Power switch on (IG) | Below 1 V |
| A42-22 (RRFG) - Body ground | Power switch on (IG) | Below 1 V |
| A42-29 (RSN) - Body ground | Power switch on (IG) | Below 1 V |
| A42-30 (RSNG) - Body ground | Power switch on (IG) | Below 1 V |
| A42-11 (RCS) - Body ground | Power switch on (IG) | Below 1 V |
| A42-23 (RCSG) - Body ground | Power switch on (IG) | Below 1 V |
Turn the power switch off.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A42-21 (RRF) - A42-22 (RRFG) | Power switch off | 7.65 to 10.2 Ω |
| A42-29 (RSN) - A42-30 (RSNG) | Power switch off | 12.6 to 16.8 Ω |
| A42-11 (RCS) - A42-23 (RCSG) | Power switch off | 12.6 to 16.8 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A42-21 (RRF) or A42-22 (RRFG) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A42-29 (RSN) or A42-30 (RSNG) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A42-11 (RCS) or A42-23 (RCSG) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
|
| ||||
| OK | |
| 11.CHECK CONNECTOR CONNECTION CONDITION (REAR MOTOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the rear motor resolver connector.
|
| ||||
| OK | ||
| ||
| 12.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the motor resolver connector.
|
| ||||
| OK | |
| 13.CHECK MOTOR RESOLVER |
![]() |
Disconnect the motor resolver connector.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B54-1 (MRF) - B54-4 (MRFG) | Power switch off | 7.65 to 10.2 Ω |
| B54-2 (MSN) - B54-5 (MSNG) | Power switch off | 12.6 to 16.8 Ω |
| B54-3 (MCS) - B54-6 (MCSG) | Power switch off | 12.6 to 16.8 Ω |
Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B54-1 (MRF) - B54-2 (MSN) | Power switch off | 10 MΩ or higher |
| B54-1 (MRF) - B54-3 (MCS) | Power switch off | 10 MΩ or higher |
| B54-2 (MSN) - B54-3 (MCS) | Power switch off | 10 MΩ or higher |
| B54-4 (MRFG) - B54-5 (MSNG) | Power switch off | 10 MΩ or higher |
| B54-4 (MRFG) - B54-6 (MCSG) | Power switch off | 10 MΩ or higher |
| B54-5 (MSNG) - B54-6 (MCSG) | Power switch off | 10 MΩ or higher |
| Each terminal listed above - Transaxle housing | Power switch off | 10 MΩ or higher |
|
| ||||
| OK | ||
| ||
| 14.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR) |
Remove the inverter with converter assembly (Click here).
![]() |
Check the connection of the generator resolver connector.
|
| ||||
| OK | |
| 15.CHECK GENERATOR RESOLVER |
Remove the inverter with converter assembly (Click here).
![]() |
Disconnect the generator resolver connector.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B53-1 (GRF) - B53-6 (GRFG) | Power switch off | 7.65 to 10.2 Ω |
| B53-2 (GSN) - B53-7 (GSNG) | Power switch off | 12.6 to 16.8 Ω |
| B53-3 (GCS) - B53-8 (GCSG) | Power switch off | 12.6 to 16.8 Ω |
Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B53-1 (GRF) - B53-2 (GSN) | Power switch off | 10 MΩ or higher |
| B53-1 (GRF) - B53-3 (GCS) | Power switch off | 10 MΩ or higher |
| B53-2 (GSN) - B53-3 (GCS) | Power switch off | 10 MΩ or higher |
| B53-6 (GRFG) - B53-7 (GSNG) | Power switch off | 10 MΩ or higher |
| B53-6 (GRFG) - B53-8 (GCSG) | Power switch off | 10 MΩ or higher |
| B53-7 (GSNG) - B53-8 (GCSG) | Power switch off | 10 MΩ or higher |
| Each terminal listed above - Transaxle housing | Power switch off | 10 MΩ or higher |
|
| ||||
| OK | ||
| ||
| 16.CHECK CONNECTOR CONNECTION CONDITION (REAR MOTOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the rear motor resolver connector.
|
| ||||
| OK | |
| 17.CHECK REAR TRACTION MOTOR WITH TRANSAXLE ASSEMBLY (REAR MOTOR RESOLVER) |
![]() |
Disconnect the rear motor resolver connector.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| j7-1 (RRF) - j7-4 (RRFG) | Power switch off | 7.65 to 10.2 Ω |
| j7-2 (RSN) - j7-5 (RSNG) | Power switch off | 12.6 to 16.8 Ω |
| j7-3 (RCS) - j7-6 (RCSG) | Power switch off | 12.6 to 16.8 Ω |
Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| j7-1 (RRF) - j7-2 (RSN) | Power switch off | 10 MΩ or higher |
| j7-1 (RRF) - j7-3 (RCS) | Power switch off | 10 MΩ or higher |
| j7-2 (RSN) - j7-3 (RCS) | Power switch off | 10 MΩ or higher |
| j7-4 (RRFG) - j7-5 (RSNG) | Power switch off | 10 MΩ or higher |
| j7-4 (RRFG) - j7-6 (RCSG) | Power switch off | 10 MΩ or higher |
| j7-5 (RSNG) - j7-6 (RCSG) | Power switch off | 10 MΩ or higher |
| Each terminal listed above - Transaxle housing | Power switch off | 10 MΩ or higher |
|
| ||||
| OK | ||
| ||